An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.

PURPOSE: Velocity-selective arterial spin labeling (VSASL) tags arterial blood on a velocity-selective (VS) basis and eliminates the tagging/imaging gap and associated transit delay sensitivity observed in other ASL tagging methods. However, the flow-weighting gradient pulses in VS tag preparation c...

Full description

Bibliographic Details
Main Authors: Guo, J, Meakin, J, Jezzard, P, Wong, E
Format: Journal article
Language:English
Published: 2015
_version_ 1826259326992384000
author Guo, J
Meakin, J
Jezzard, P
Wong, E
author_facet Guo, J
Meakin, J
Jezzard, P
Wong, E
author_sort Guo, J
collection OXFORD
description PURPOSE: Velocity-selective arterial spin labeling (VSASL) tags arterial blood on a velocity-selective (VS) basis and eliminates the tagging/imaging gap and associated transit delay sensitivity observed in other ASL tagging methods. However, the flow-weighting gradient pulses in VS tag preparation can generate eddy currents (ECs), which may erroneously tag the static tissue and create artificial perfusion signal, compromising the accuracy of perfusion quantification. METHODS: A novel VS preparation design is presented using an eight-segment B1 insensitive rotation with symmetric radio frequency and gradient layouts (sym-BIR-8), combined with delays after gradient pulses to optimally reduce ECs of a wide range of time constants while maintaining B0 and B1 insensitivity. Bloch simulation, phantom, and in vivo experiments were carried out to determine robustness of the new and existing pulse designs to ECs, B0 , and B1 inhomogeneity. RESULTS: VSASL with reduced EC sensitivity across a wide range of EC time constants was achieved with the proposed sym-BIR-8 design, and the accuracy of cerebral blood flow measurement was improved. CONCLUSION: The sym-BIR-8 design performed the most robustly among the existing VS tagging designs, and should benefit studies using VS preparation with improved accuracy and reliability.
first_indexed 2024-03-06T18:48:06Z
format Journal article
id oxford-uuid:0f3b6dcc-4d83-4be3-a140-36f3120418db
institution University of Oxford
language English
last_indexed 2024-03-06T18:48:06Z
publishDate 2015
record_format dspace
spelling oxford-uuid:0f3b6dcc-4d83-4be3-a140-36f3120418db2022-03-26T09:50:10ZAn optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:0f3b6dcc-4d83-4be3-a140-36f3120418dbEnglishSymplectic Elements at Oxford2015Guo, JMeakin, JJezzard, PWong, EPURPOSE: Velocity-selective arterial spin labeling (VSASL) tags arterial blood on a velocity-selective (VS) basis and eliminates the tagging/imaging gap and associated transit delay sensitivity observed in other ASL tagging methods. However, the flow-weighting gradient pulses in VS tag preparation can generate eddy currents (ECs), which may erroneously tag the static tissue and create artificial perfusion signal, compromising the accuracy of perfusion quantification. METHODS: A novel VS preparation design is presented using an eight-segment B1 insensitive rotation with symmetric radio frequency and gradient layouts (sym-BIR-8), combined with delays after gradient pulses to optimally reduce ECs of a wide range of time constants while maintaining B0 and B1 insensitivity. Bloch simulation, phantom, and in vivo experiments were carried out to determine robustness of the new and existing pulse designs to ECs, B0 , and B1 inhomogeneity. RESULTS: VSASL with reduced EC sensitivity across a wide range of EC time constants was achieved with the proposed sym-BIR-8 design, and the accuracy of cerebral blood flow measurement was improved. CONCLUSION: The sym-BIR-8 design performed the most robustly among the existing VS tagging designs, and should benefit studies using VS preparation with improved accuracy and reliability.
spellingShingle Guo, J
Meakin, J
Jezzard, P
Wong, E
An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.
title An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.
title_full An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.
title_fullStr An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.
title_full_unstemmed An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.
title_short An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.
title_sort optimized design to reduce eddy current sensitivity in velocity selective arterial spin labeling using symmetric bir 8 pulses
work_keys_str_mv AT guoj anoptimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses
AT meakinj anoptimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses
AT jezzardp anoptimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses
AT wonge anoptimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses
AT guoj optimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses
AT meakinj optimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses
AT jezzardp optimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses
AT wonge optimizeddesigntoreduceeddycurrentsensitivityinvelocityselectivearterialspinlabelingusingsymmetricbir8pulses