Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility

A turbine efficiency measurement system has been developed and installed on the turbine test facility (TTF) at QinetiQ Farnborough. The TTF is an engine-scale short-duration (0.5 s run time) rotating transonic facility, which can operate as either single stage (HP vane and rotor) or 11/2 stage (HP s...

Full description

Bibliographic Details
Main Authors: Beard, P, Povey, T, Chana, K
Format: Journal article
Language:English
Published: 2010
_version_ 1826259681233862656
author Beard, P
Povey, T
Chana, K
author_facet Beard, P
Povey, T
Chana, K
author_sort Beard, P
collection OXFORD
description A turbine efficiency measurement system has been developed and installed on the turbine test facility (TTF) at QinetiQ Farnborough. The TTF is an engine-scale short-duration (0.5 s run time) rotating transonic facility, which can operate as either single stage (HP vane and rotor) or 11/2 stage (HP stage with IP or LP vane). The current MT1 HP stage is highly loaded and unshrouded and is therefore relevant to current design trends. Implementation of the efficiency measurement system forms part of the EU Turbine Aero-Thermal External Flows (TATEF II) program. The following aspects of the efficiency measurement system are discussed in this paper: mass-flow rate measurement, power measurement by direct torque measurement, turbine inlet and exit area traverse measurement systems, computation of efficiency by mass weighting, and uncertainty analysis of the experimentally determined turbine efficiency. The calibration of the mass-flow rate and torque measurement systems are also discussed. Emphasis was placed on the need for a low efficiency precision uncertainty, so that changes in efficiency associated with turbine inlet temperature distortion and swirl can be resolved with good accuracy. Measurements with inlet flow distortion form part of the TATEF II program and will be the subject of forthcoming publications. © 2010 by ASME.
first_indexed 2024-03-06T18:53:39Z
format Journal article
id oxford-uuid:11182a31-53dc-43b3-b4b0-0317d6e0c4f0
institution University of Oxford
language English
last_indexed 2024-03-06T18:53:39Z
publishDate 2010
record_format dspace
spelling oxford-uuid:11182a31-53dc-43b3-b4b0-0317d6e0c4f02022-03-26T10:00:14ZTurbine Efficiency Measurement System for the QinetiQ Turbine Test FacilityJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:11182a31-53dc-43b3-b4b0-0317d6e0c4f0EnglishSymplectic Elements at Oxford2010Beard, PPovey, TChana, KA turbine efficiency measurement system has been developed and installed on the turbine test facility (TTF) at QinetiQ Farnborough. The TTF is an engine-scale short-duration (0.5 s run time) rotating transonic facility, which can operate as either single stage (HP vane and rotor) or 11/2 stage (HP stage with IP or LP vane). The current MT1 HP stage is highly loaded and unshrouded and is therefore relevant to current design trends. Implementation of the efficiency measurement system forms part of the EU Turbine Aero-Thermal External Flows (TATEF II) program. The following aspects of the efficiency measurement system are discussed in this paper: mass-flow rate measurement, power measurement by direct torque measurement, turbine inlet and exit area traverse measurement systems, computation of efficiency by mass weighting, and uncertainty analysis of the experimentally determined turbine efficiency. The calibration of the mass-flow rate and torque measurement systems are also discussed. Emphasis was placed on the need for a low efficiency precision uncertainty, so that changes in efficiency associated with turbine inlet temperature distortion and swirl can be resolved with good accuracy. Measurements with inlet flow distortion form part of the TATEF II program and will be the subject of forthcoming publications. © 2010 by ASME.
spellingShingle Beard, P
Povey, T
Chana, K
Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility
title Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility
title_full Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility
title_fullStr Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility
title_full_unstemmed Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility
title_short Turbine Efficiency Measurement System for the QinetiQ Turbine Test Facility
title_sort turbine efficiency measurement system for the qinetiq turbine test facility
work_keys_str_mv AT beardp turbineefficiencymeasurementsystemfortheqinetiqturbinetestfacility
AT poveyt turbineefficiencymeasurementsystemfortheqinetiqturbinetestfacility
AT chanak turbineefficiencymeasurementsystemfortheqinetiqturbinetestfacility