Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement

<p><strong>Purpose:</strong> The Oxford unicompartmental knee replacement (UKR) has a fully congruent mobile bearing to minimise wear. However, with younger higher demand patients, wear remains a concern. The aim of this study was to quantify the wear rate of Phase 3 Oxford UKR bea...

Full description

Bibliographic Details
Main Authors: Ghosh, P, Mohammad, HR, Martin, B, Campi, S, Murray, DW, Mellon, SJ
Format: Journal article
Language:English
Published: Springer 2020
_version_ 1797055284748746752
author Ghosh, P
Mohammad, HR
Martin, B
Campi, S
Murray, DW
Mellon, SJ
author_facet Ghosh, P
Mohammad, HR
Martin, B
Campi, S
Murray, DW
Mellon, SJ
author_sort Ghosh, P
collection OXFORD
description <p><strong>Purpose:</strong> The Oxford unicompartmental knee replacement (UKR) has a fully congruent mobile bearing to minimise wear. However, with younger higher demand patients, wear remains a concern. The aim of this study was to quantify the wear rate of Phase 3 Oxford UKR bearings over the course of 5&#xA0;years and to identify the factors that influence it.</p> <p><strong>Methods:</strong> 40 medial Oxford UKRs recruited for a randomised study of cemented and cementless fixation were studied with Radiostereometric analysis (RSA) at 1&#xA0;week, 3&#xA0;months, 6&#xA0;months, 1&#xA0;year, 2&#xA0;years, and 5&#xA0;years post-operatively and bearing thickness was calculated. Penetration, defined as the change in thickness compared to the 1-week measurement, was determined. Creep (early penetration) and wear (late penetration at a constant rate) were calculated. The influence of demographic factors, Oxford Knee Score (OKS), Tegner score, fixation and bearing overhang (determined by RSA) on wear was analysed.</p> <p><strong>Results:</strong> After 6&#xA0;months the penetration rate was constant, indicating that wear alone was occurring. The wear rate was 0.07&#xA0;mm/year (SD 0.03). The creep was 0.06&#xA0;mm with about 95% occurring during the first 3&#xA0;months. There was no significant relationship between fixation (cemented/cementless), age, component size, OKS and Tegner score with wear rate. Increasing BMI was associated with decreasing wear (p = 0.042). 37/40 bearings overhung the tibia to some extent and 23/40 overhung the tibia medially. An increase in the area of overhang (p = 0.036), amount of medial overhang (p = 0.028) and distance between the bearing and tibial wall (p = 0.019) were associated with increased wear. Bearings that did not overhang (0.06&#xA0;mm/year) had less wear (p = 0.025) than those that did (0.08&#xA0;mm/year). There was no relationship (p = 0.6) between the femoral contact area and wear.</p> <p><strong>Conclusion:</strong> During the first three to six months after implantation, the bearing becomes 0.06&#xA0;mm thinner due to creep. The combined wear rate of the upper and lower surfaces of the bearing is constant (0.07&#xA0;mm/year). The wear is lower if the bearing does not overhang the tibia so surgeons should aim for the bearing to be close to the tibial wall. The orientation of the femoral component does not influence wear. Level of evidence: Retrospective Study, Level III.</p>
first_indexed 2024-03-06T19:08:29Z
format Journal article
id oxford-uuid:15fa336d-a17a-4b38-a251-3f43cdd622f6
institution University of Oxford
language English
last_indexed 2024-03-06T19:08:29Z
publishDate 2020
publisher Springer
record_format dspace
spelling oxford-uuid:15fa336d-a17a-4b38-a251-3f43cdd622f62022-03-26T10:28:30ZLow polyethylene creep and wear following mobile-bearing unicompartmental knee replacementJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:15fa336d-a17a-4b38-a251-3f43cdd622f6EnglishSymplectic ElementsSpringer2020Ghosh, PMohammad, HRMartin, BCampi, SMurray, DWMellon, SJ<p><strong>Purpose:</strong> The Oxford unicompartmental knee replacement (UKR) has a fully congruent mobile bearing to minimise wear. However, with younger higher demand patients, wear remains a concern. The aim of this study was to quantify the wear rate of Phase 3 Oxford UKR bearings over the course of 5&#xA0;years and to identify the factors that influence it.</p> <p><strong>Methods:</strong> 40 medial Oxford UKRs recruited for a randomised study of cemented and cementless fixation were studied with Radiostereometric analysis (RSA) at 1&#xA0;week, 3&#xA0;months, 6&#xA0;months, 1&#xA0;year, 2&#xA0;years, and 5&#xA0;years post-operatively and bearing thickness was calculated. Penetration, defined as the change in thickness compared to the 1-week measurement, was determined. Creep (early penetration) and wear (late penetration at a constant rate) were calculated. The influence of demographic factors, Oxford Knee Score (OKS), Tegner score, fixation and bearing overhang (determined by RSA) on wear was analysed.</p> <p><strong>Results:</strong> After 6&#xA0;months the penetration rate was constant, indicating that wear alone was occurring. The wear rate was 0.07&#xA0;mm/year (SD 0.03). The creep was 0.06&#xA0;mm with about 95% occurring during the first 3&#xA0;months. There was no significant relationship between fixation (cemented/cementless), age, component size, OKS and Tegner score with wear rate. Increasing BMI was associated with decreasing wear (p = 0.042). 37/40 bearings overhung the tibia to some extent and 23/40 overhung the tibia medially. An increase in the area of overhang (p = 0.036), amount of medial overhang (p = 0.028) and distance between the bearing and tibial wall (p = 0.019) were associated with increased wear. Bearings that did not overhang (0.06&#xA0;mm/year) had less wear (p = 0.025) than those that did (0.08&#xA0;mm/year). There was no relationship (p = 0.6) between the femoral contact area and wear.</p> <p><strong>Conclusion:</strong> During the first three to six months after implantation, the bearing becomes 0.06&#xA0;mm thinner due to creep. The combined wear rate of the upper and lower surfaces of the bearing is constant (0.07&#xA0;mm/year). The wear is lower if the bearing does not overhang the tibia so surgeons should aim for the bearing to be close to the tibial wall. The orientation of the femoral component does not influence wear. Level of evidence: Retrospective Study, Level III.</p>
spellingShingle Ghosh, P
Mohammad, HR
Martin, B
Campi, S
Murray, DW
Mellon, SJ
Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement
title Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement
title_full Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement
title_fullStr Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement
title_full_unstemmed Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement
title_short Low polyethylene creep and wear following mobile-bearing unicompartmental knee replacement
title_sort low polyethylene creep and wear following mobile bearing unicompartmental knee replacement
work_keys_str_mv AT ghoshp lowpolyethylenecreepandwearfollowingmobilebearingunicompartmentalkneereplacement
AT mohammadhr lowpolyethylenecreepandwearfollowingmobilebearingunicompartmentalkneereplacement
AT martinb lowpolyethylenecreepandwearfollowingmobilebearingunicompartmentalkneereplacement
AT campis lowpolyethylenecreepandwearfollowingmobilebearingunicompartmentalkneereplacement
AT murraydw lowpolyethylenecreepandwearfollowingmobilebearingunicompartmentalkneereplacement
AT mellonsj lowpolyethylenecreepandwearfollowingmobilebearingunicompartmentalkneereplacement