A study of the kinetics of copper vapour lasers

<p>A 42 mm bore, 40 W copper vapour laser (CVL) has been set up in a test rig in order to measure the values of many of the parameters of the laser as a function of time in the laser pulse-delay cycle, and of radial position in the plasma tube, while at all times running under standard operati...

Full description

Bibliographic Details
Main Author: Hogan, G
Format: Thesis
Published: 1993
_version_ 1826315752719777792
author Hogan, G
author_facet Hogan, G
author_sort Hogan, G
collection OXFORD
description <p>A 42 mm bore, 40 W copper vapour laser (CVL) has been set up in a test rig in order to measure the values of many of the parameters of the laser as a function of time in the laser pulse-delay cycle, and of radial position in the plasma tube, while at all times running under standard operating conditions. In this way it has been possible to obtain the world's first truly comprehensive parameter map of the CVL in which all of the measurements have been performed upon the same device, operating under identical conditions and with all times accurately referenced to a datum. It is intended that this set of data is primarily for the benefit of those involved in the computer modelling of the CVL plasma, however initial analysis of the results obtained has been undertaken.</p> <p>All diagnostic techniques have been carefully selected as offering the highest possible level of accuracy and freedom from assumptions, and each one employed has been described in detail in terms of both theory and practical application. The hook method has been used for the measurement of the population density in the copper ground state, the upper and lower laser levels, one of the copper quartet levels, and one of the neon metastable levels, each with a time resolution of 5 ns, and a radial resolution of 2 mm. The electron density has been measured, also with a radial resolution of 2 mm and with nanosecond time resolution using a two colour interferometric technique employing the measurement of the refractive index of the plasma at 10.6 μm and 670 nm. Measurement has been made of the voltage on the laser electrodes and the current flowing in the laser during the discharge.</p> <p>Ancillary experiments have been performed to study the CVL discharge which have yielded some unexpected results, and measurements have been performed on a 60 mm bore CVL to determine fully the mechanism of the time delay between the onset of lasing at the plasma tube wall and on axis, and novel observations have been made.</p>
first_indexed 2024-03-06T19:12:44Z
format Thesis
id oxford-uuid:174eb6ce-3576-49c1-add4-5e1b0d2e1571
institution University of Oxford
last_indexed 2024-12-09T03:31:44Z
publishDate 1993
record_format dspace
spelling oxford-uuid:174eb6ce-3576-49c1-add4-5e1b0d2e15712024-12-01T15:06:45ZA study of the kinetics of copper vapour lasersThesishttp://purl.org/coar/resource_type/c_db06uuid:174eb6ce-3576-49c1-add4-5e1b0d2e1571Polonsky Theses Digitisation Project1993Hogan, G<p>A 42 mm bore, 40 W copper vapour laser (CVL) has been set up in a test rig in order to measure the values of many of the parameters of the laser as a function of time in the laser pulse-delay cycle, and of radial position in the plasma tube, while at all times running under standard operating conditions. In this way it has been possible to obtain the world's first truly comprehensive parameter map of the CVL in which all of the measurements have been performed upon the same device, operating under identical conditions and with all times accurately referenced to a datum. It is intended that this set of data is primarily for the benefit of those involved in the computer modelling of the CVL plasma, however initial analysis of the results obtained has been undertaken.</p> <p>All diagnostic techniques have been carefully selected as offering the highest possible level of accuracy and freedom from assumptions, and each one employed has been described in detail in terms of both theory and practical application. The hook method has been used for the measurement of the population density in the copper ground state, the upper and lower laser levels, one of the copper quartet levels, and one of the neon metastable levels, each with a time resolution of 5 ns, and a radial resolution of 2 mm. The electron density has been measured, also with a radial resolution of 2 mm and with nanosecond time resolution using a two colour interferometric technique employing the measurement of the refractive index of the plasma at 10.6 μm and 670 nm. Measurement has been made of the voltage on the laser electrodes and the current flowing in the laser during the discharge.</p> <p>Ancillary experiments have been performed to study the CVL discharge which have yielded some unexpected results, and measurements have been performed on a 60 mm bore CVL to determine fully the mechanism of the time delay between the onset of lasing at the plasma tube wall and on axis, and novel observations have been made.</p>
spellingShingle Hogan, G
A study of the kinetics of copper vapour lasers
title A study of the kinetics of copper vapour lasers
title_full A study of the kinetics of copper vapour lasers
title_fullStr A study of the kinetics of copper vapour lasers
title_full_unstemmed A study of the kinetics of copper vapour lasers
title_short A study of the kinetics of copper vapour lasers
title_sort study of the kinetics of copper vapour lasers
work_keys_str_mv AT hogang astudyofthekineticsofcoppervapourlasers
AT hogang studyofthekineticsofcoppervapourlasers