Potential Step Chronoamperometry at Microdisc Electrodes: Effect of Finite Electrode Kinetics
Potential step chronoamperometry at microdisc electrodes is studied for a simple one electron reduction (A + e- ⇌ B). Simulations are used to explore quantitatively the effect of electrode kinetics on the current-time transients resulting from such measurements. The use of these transients to extrac...
Автори: | Belding, SR, Rogers, E, Compton, R |
---|---|
Формат: | Journal article |
Мова: | English |
Опубліковано: |
2009
|
Схожі ресурси
Схожі ресурси
-
Adaptive finite element simulation of chronoamperometry at microdisc electrodes
за авторством: Harriman, K, та інші
Опубліковано: (2003) -
Adaptive Finite Element Simulation of Chronoamperometry at Microdisc Electrodes
за авторством: Harriman, K, та інші
Опубліковано: (2003) -
Adaptive finite element simulation of chronoamperometry at microdisc electrodes
за авторством: Harriman, K, та інші
Опубліковано: (2003) -
Steady-state voltammetry at a microdisc electrode in the absence of excess supporting electrolyte for reversible, quasi-reversible and irreversible electrode kinetics.
за авторством: Belding, SR, та інші
Опубліковано: (2012) -
THE WALL-JET ELECTRODE POTENTIAL STEP CHRONOAMPEROMETRY
за авторством: Fisher, A, та інші
Опубліковано: (1991)