Determining appropriate stiffness levels for spudcan foundations using jack-up case records

The level of soil stiffness under spudcan footings is an area of intense interest and debate, with many practitioners believing that current jack-up assessment guidelines are overly conservative. In order to evaluate appropriate stiffness parameters, back-analysis of case records of jack-up platform...

Ausführliche Beschreibung

Bibliographische Detailangaben
Hauptverfasser: Cassidy, M, Hoyle, M, Houlsby, G, Marcom, MR
Format: Conference item
Veröffentlicht: 2002
_version_ 1826261087964626944
author Cassidy, M
Hoyle, M
Houlsby, G
Marcom, MR
author_facet Cassidy, M
Hoyle, M
Houlsby, G
Marcom, MR
author_sort Cassidy, M
collection OXFORD
description The level of soil stiffness under spudcan footings is an area of intense interest and debate, with many practitioners believing that current jack-up assessment guidelines are overly conservative. In order to evaluate appropriate stiffness parameters, back-analysis of case records of jack-up platforms in the North Sea has been performed. The records relate to three different rigs at a total of eight locations, which include a variety of soil conditions, water depths and sea-state severity. For each site the horizontal deck displacements and the sea-state conditions under storm loading are available. Numerical simulation of the platforms under storm loading was undertaken with varying levels of foundation stiffness. For each set of stiffness one-hour of numerical simulation was performed, with the most severe recorded environmental loading conditions for that site used. The horizontal deck displacements of the measured data and the numerical simulation results have been compared in both the frequency domain and by the magnitude of response. On the basis of the analyses, recommendations can be made for higher stiffness factors then are currently suggested in the SNAME, 1997 Technical and Research Bulletin 5-5A, Site Specific Assessment of Mobile Jack-up Units (SNAME, 1997).
first_indexed 2024-03-06T19:16:04Z
format Conference item
id oxford-uuid:186b6ebc-c047-40c1-a84a-cf94880a9518
institution University of Oxford
last_indexed 2024-03-06T19:16:04Z
publishDate 2002
record_format dspace
spelling oxford-uuid:186b6ebc-c047-40c1-a84a-cf94880a95182022-03-26T10:43:07ZDetermining appropriate stiffness levels for spudcan foundations using jack-up case recordsConference itemhttp://purl.org/coar/resource_type/c_5794uuid:186b6ebc-c047-40c1-a84a-cf94880a9518Symplectic Elements at Oxford2002Cassidy, MHoyle, MHoulsby, GMarcom, MRThe level of soil stiffness under spudcan footings is an area of intense interest and debate, with many practitioners believing that current jack-up assessment guidelines are overly conservative. In order to evaluate appropriate stiffness parameters, back-analysis of case records of jack-up platforms in the North Sea has been performed. The records relate to three different rigs at a total of eight locations, which include a variety of soil conditions, water depths and sea-state severity. For each site the horizontal deck displacements and the sea-state conditions under storm loading are available. Numerical simulation of the platforms under storm loading was undertaken with varying levels of foundation stiffness. For each set of stiffness one-hour of numerical simulation was performed, with the most severe recorded environmental loading conditions for that site used. The horizontal deck displacements of the measured data and the numerical simulation results have been compared in both the frequency domain and by the magnitude of response. On the basis of the analyses, recommendations can be made for higher stiffness factors then are currently suggested in the SNAME, 1997 Technical and Research Bulletin 5-5A, Site Specific Assessment of Mobile Jack-up Units (SNAME, 1997).
spellingShingle Cassidy, M
Hoyle, M
Houlsby, G
Marcom, MR
Determining appropriate stiffness levels for spudcan foundations using jack-up case records
title Determining appropriate stiffness levels for spudcan foundations using jack-up case records
title_full Determining appropriate stiffness levels for spudcan foundations using jack-up case records
title_fullStr Determining appropriate stiffness levels for spudcan foundations using jack-up case records
title_full_unstemmed Determining appropriate stiffness levels for spudcan foundations using jack-up case records
title_short Determining appropriate stiffness levels for spudcan foundations using jack-up case records
title_sort determining appropriate stiffness levels for spudcan foundations using jack up case records
work_keys_str_mv AT cassidym determiningappropriatestiffnesslevelsforspudcanfoundationsusingjackupcaserecords
AT hoylem determiningappropriatestiffnesslevelsforspudcanfoundationsusingjackupcaserecords
AT houlsbyg determiningappropriatestiffnesslevelsforspudcanfoundationsusingjackupcaserecords
AT marcommr determiningappropriatestiffnesslevelsforspudcanfoundationsusingjackupcaserecords