An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.

Hyperoxia is known to cause an increase in the blood oxygenation level dependent (BOLD) signal that is primarily localised to the venous vasculature. This contrast mechanism has been proposed as a way to measure venous cerebral blood volume (CBVv) without the need for more invasive contrast media. I...

Full description

Bibliographic Details
Main Authors: Blockley, N, Griffeth, V, Germuska, M, Bulte, D, Buxton, R
Format: Journal article
Language:English
Published: 2013
_version_ 1826261363898449920
author Blockley, N
Griffeth, V
Germuska, M
Bulte, D
Buxton, R
author_facet Blockley, N
Griffeth, V
Germuska, M
Bulte, D
Buxton, R
author_sort Blockley, N
collection OXFORD
description Hyperoxia is known to cause an increase in the blood oxygenation level dependent (BOLD) signal that is primarily localised to the venous vasculature. This contrast mechanism has been proposed as a way to measure venous cerebral blood volume (CBVv) without the need for more invasive contrast media. In the existing method the analysis modelled the data as a dynamic contrast agent experiment, with the assumption that the BOLD signal of tissue was dominated by intravascular signal. The effects on the accuracy of the method due to extravascular BOLD signal changes, as well as signal modulation by intersubject differences in baseline physiology, such as haematocrit and oxygen extraction fraction, have so far been unexplored. In this study the effect of extravascular signal and intersubject physiological variability was investigated by simulating the hyperoxia CBVv experiment using a detailed BOLD signal model. This analysis revealed substantial uncertainty in the measurement of CBVv using the existing analysis based on dynamic contrast agent experiments. Instead, the modelling showed a simple and direct relationship between the BOLD signal change and CBVv, and an alternative analysis method with much reduced uncertainty was proposed based on this finding. Both methods were tested experimentally, with the new method producing results that are consistent with the limited literature in this area.
first_indexed 2024-03-06T19:20:14Z
format Journal article
id oxford-uuid:19d65a24-fe2a-4ee2-ac60-be478795fbb9
institution University of Oxford
language English
last_indexed 2024-03-06T19:20:14Z
publishDate 2013
record_format dspace
spelling oxford-uuid:19d65a24-fe2a-4ee2-ac60-be478795fbb92022-03-26T10:51:16ZAn analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:19d65a24-fe2a-4ee2-ac60-be478795fbb9EnglishSymplectic Elements at Oxford2013Blockley, NGriffeth, VGermuska, MBulte, DBuxton, RHyperoxia is known to cause an increase in the blood oxygenation level dependent (BOLD) signal that is primarily localised to the venous vasculature. This contrast mechanism has been proposed as a way to measure venous cerebral blood volume (CBVv) without the need for more invasive contrast media. In the existing method the analysis modelled the data as a dynamic contrast agent experiment, with the assumption that the BOLD signal of tissue was dominated by intravascular signal. The effects on the accuracy of the method due to extravascular BOLD signal changes, as well as signal modulation by intersubject differences in baseline physiology, such as haematocrit and oxygen extraction fraction, have so far been unexplored. In this study the effect of extravascular signal and intersubject physiological variability was investigated by simulating the hyperoxia CBVv experiment using a detailed BOLD signal model. This analysis revealed substantial uncertainty in the measurement of CBVv using the existing analysis based on dynamic contrast agent experiments. Instead, the modelling showed a simple and direct relationship between the BOLD signal change and CBVv, and an alternative analysis method with much reduced uncertainty was proposed based on this finding. Both methods were tested experimentally, with the new method producing results that are consistent with the limited literature in this area.
spellingShingle Blockley, N
Griffeth, V
Germuska, M
Bulte, D
Buxton, R
An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.
title An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.
title_full An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.
title_fullStr An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.
title_full_unstemmed An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.
title_short An analysis of the use of hyperoxia for measuring venous cerebral blood volume: comparison of the existing method with a new analysis approach.
title_sort analysis of the use of hyperoxia for measuring venous cerebral blood volume comparison of the existing method with a new analysis approach
work_keys_str_mv AT blockleyn ananalysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT griffethv ananalysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT germuskam ananalysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT bulted ananalysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT buxtonr ananalysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT blockleyn analysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT griffethv analysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT germuskam analysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT bulted analysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach
AT buxtonr analysisoftheuseofhyperoxiaformeasuringvenouscerebralbloodvolumecomparisonoftheexistingmethodwithanewanalysisapproach