Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.

1. Under conditions of both euoxia and hypoxia, it is generally accepted that the ventilatory response to CO2 has both rapid (peripheral chemoreflex) and slow (central chemoreflex) components. However, under conditions of hyperoxia, it is unclear in humans whether the fast component is completely ab...

Full description

Bibliographic Details
Main Authors: Pedersen, M, Fatemian, M, Robbins, P
Format: Journal article
Language:English
Published: 1999
_version_ 1797056611052683264
author Pedersen, M
Fatemian, M
Robbins, P
author_facet Pedersen, M
Fatemian, M
Robbins, P
author_sort Pedersen, M
collection OXFORD
description 1. Under conditions of both euoxia and hypoxia, it is generally accepted that the ventilatory response to CO2 has both rapid (peripheral chemoreflex) and slow (central chemoreflex) components. However, under conditions of hyperoxia, it is unclear in humans whether the fast component is completely abolished or merely attenuated in magnitude. 2. The present study develops a technique to determine whether or not a two-compartment model fits the ventilatory response to CO2 significantly better than a one-compartment model. Data were collected under both hypoxic (end-tidal PO2 = 50 Torr) conditions, when two components would be expected, and under hyperoxic (end-tidal PO2 = 200 Torr) conditions, when the presence of the fast compartment is under question. 3. Ten subjects were recruited, of whom nine completed the study. The end-tidal PCO2 of each subject was varied according to a multi-frequency binary sequence that involved 13 steps into and 13 steps out of hypercapnia lasting altogether 1408 s. 4. In four out of nine subjects in hypoxia, and six out of nine subjects in hyperoxia, the two-compartment model fitted the data significantly better than the one-compartment model (F ratio test on residuals). This improvement in fit was significant for the pooled data in both hypoxia (P < 0.05) and hyperoxia (P < 0.005). Mean ventilatory sensitivities for the central chemoreflex were (mean +/- s.e.m.) 1. 69 +/- 0.39 l min-1 Torr-1 in hypoxia and 2.00 +/- 0.32 l min-1 Torr-1 in hyperoxia. Mean ventilatory sensitivities for the peripheral chemoreflex were 2.42 +/- 0.36 l min-1 Torr-1 in hypoxia and 0.75 +/- 0.16 l min-1 Torr-1 in hyperoxia. 5. It is concluded that the rapid and slow components of the ventilatory response to CO2 can be separately identified, and that a rapid component persists under conditions of hyperoxia.
first_indexed 2024-03-06T19:25:01Z
format Journal article
id oxford-uuid:1b6956fb-9d1d-4e00-a688-d116bace0a5e
institution University of Oxford
language English
last_indexed 2024-03-06T19:25:01Z
publishDate 1999
record_format dspace
spelling oxford-uuid:1b6956fb-9d1d-4e00-a688-d116bace0a5e2022-03-26T11:00:11ZIdentification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:1b6956fb-9d1d-4e00-a688-d116bace0a5eEnglishSymplectic Elements at Oxford1999Pedersen, MFatemian, MRobbins, P1. Under conditions of both euoxia and hypoxia, it is generally accepted that the ventilatory response to CO2 has both rapid (peripheral chemoreflex) and slow (central chemoreflex) components. However, under conditions of hyperoxia, it is unclear in humans whether the fast component is completely abolished or merely attenuated in magnitude. 2. The present study develops a technique to determine whether or not a two-compartment model fits the ventilatory response to CO2 significantly better than a one-compartment model. Data were collected under both hypoxic (end-tidal PO2 = 50 Torr) conditions, when two components would be expected, and under hyperoxic (end-tidal PO2 = 200 Torr) conditions, when the presence of the fast compartment is under question. 3. Ten subjects were recruited, of whom nine completed the study. The end-tidal PCO2 of each subject was varied according to a multi-frequency binary sequence that involved 13 steps into and 13 steps out of hypercapnia lasting altogether 1408 s. 4. In four out of nine subjects in hypoxia, and six out of nine subjects in hyperoxia, the two-compartment model fitted the data significantly better than the one-compartment model (F ratio test on residuals). This improvement in fit was significant for the pooled data in both hypoxia (P < 0.05) and hyperoxia (P < 0.005). Mean ventilatory sensitivities for the central chemoreflex were (mean +/- s.e.m.) 1. 69 +/- 0.39 l min-1 Torr-1 in hypoxia and 2.00 +/- 0.32 l min-1 Torr-1 in hyperoxia. Mean ventilatory sensitivities for the peripheral chemoreflex were 2.42 +/- 0.36 l min-1 Torr-1 in hypoxia and 0.75 +/- 0.16 l min-1 Torr-1 in hyperoxia. 5. It is concluded that the rapid and slow components of the ventilatory response to CO2 can be separately identified, and that a rapid component persists under conditions of hyperoxia.
spellingShingle Pedersen, M
Fatemian, M
Robbins, P
Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.
title Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.
title_full Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.
title_fullStr Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.
title_full_unstemmed Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.
title_short Identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans.
title_sort identification of fast and slow ventilatory responses to carbon dioxide under hypoxic and hyperoxic conditions in humans
work_keys_str_mv AT pedersenm identificationoffastandslowventilatoryresponsestocarbondioxideunderhypoxicandhyperoxicconditionsinhumans
AT fatemianm identificationoffastandslowventilatoryresponsestocarbondioxideunderhypoxicandhyperoxicconditionsinhumans
AT robbinsp identificationoffastandslowventilatoryresponsestocarbondioxideunderhypoxicandhyperoxicconditionsinhumans