Microchannels as axonal amplifiers.

An implantable neural interface capable of reliable long-term high-resolution recording from peripheral nerves has yet to be developed. Device design is challenging because extracellular axonal signals are very small, decay rapidly with distance from the axon, and in myelinated fibres are concentrat...

Full description

Bibliographic Details
Main Authors: Fitzgerald, J, Lacour, S, McMahon, S, Fawcett, J
Format: Journal article
Language:English
Published: 2008
_version_ 1797057288147566592
author Fitzgerald, J
Lacour, S
McMahon, S
Fawcett, J
author_facet Fitzgerald, J
Lacour, S
McMahon, S
Fawcett, J
author_sort Fitzgerald, J
collection OXFORD
description An implantable neural interface capable of reliable long-term high-resolution recording from peripheral nerves has yet to be developed. Device design is challenging because extracellular axonal signals are very small, decay rapidly with distance from the axon, and in myelinated fibres are concentrated close to nodes of Ranvier, which are around 1 mum long and spaced several hundred micrometers apart. We present a finite element model examining the electrical behavior of axons in microchannels, and demonstrate that confining axons in such channels substantially amplifies the extracellular signal. For example, housing a 10-microm myelinated axon in a 1-cm-long channel with a 1000-microm(2) cross section is predicted to generate a peak extracellular voltage of over 10 mV. Furthermore, there is little radial signal decay within the channel, and a smooth axial variation of signal amplitude along the channel, irrespective of node location. Additional benefits include a greater extracellular voltage generated by large myelinated fibres compared to small unmyelinated axons, and the reduction of gain to unity at the end of the channel which ensures that there can be no crosstalk with electrodes in other channels nearby. A microchannel architecture seems well suited to the requirements of a peripheral nerve interface.
first_indexed 2024-03-06T19:34:10Z
format Journal article
id oxford-uuid:1e7869fb-99c9-4aa1-ade9-1a7c4088bc70
institution University of Oxford
language English
last_indexed 2024-03-06T19:34:10Z
publishDate 2008
record_format dspace
spelling oxford-uuid:1e7869fb-99c9-4aa1-ade9-1a7c4088bc702022-03-26T11:16:29ZMicrochannels as axonal amplifiers.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:1e7869fb-99c9-4aa1-ade9-1a7c4088bc70EnglishSymplectic Elements at Oxford2008Fitzgerald, JLacour, SMcMahon, SFawcett, JAn implantable neural interface capable of reliable long-term high-resolution recording from peripheral nerves has yet to be developed. Device design is challenging because extracellular axonal signals are very small, decay rapidly with distance from the axon, and in myelinated fibres are concentrated close to nodes of Ranvier, which are around 1 mum long and spaced several hundred micrometers apart. We present a finite element model examining the electrical behavior of axons in microchannels, and demonstrate that confining axons in such channels substantially amplifies the extracellular signal. For example, housing a 10-microm myelinated axon in a 1-cm-long channel with a 1000-microm(2) cross section is predicted to generate a peak extracellular voltage of over 10 mV. Furthermore, there is little radial signal decay within the channel, and a smooth axial variation of signal amplitude along the channel, irrespective of node location. Additional benefits include a greater extracellular voltage generated by large myelinated fibres compared to small unmyelinated axons, and the reduction of gain to unity at the end of the channel which ensures that there can be no crosstalk with electrodes in other channels nearby. A microchannel architecture seems well suited to the requirements of a peripheral nerve interface.
spellingShingle Fitzgerald, J
Lacour, S
McMahon, S
Fawcett, J
Microchannels as axonal amplifiers.
title Microchannels as axonal amplifiers.
title_full Microchannels as axonal amplifiers.
title_fullStr Microchannels as axonal amplifiers.
title_full_unstemmed Microchannels as axonal amplifiers.
title_short Microchannels as axonal amplifiers.
title_sort microchannels as axonal amplifiers
work_keys_str_mv AT fitzgeraldj microchannelsasaxonalamplifiers
AT lacours microchannelsasaxonalamplifiers
AT mcmahons microchannelsasaxonalamplifiers
AT fawcettj microchannelsasaxonalamplifiers