3D ultrasound fractional moving blood volume: validation of renal perfusion quantification

<p><strong>Background:</strong> Three-dimensional fractional moving blood volume (3D-FMBV) derived from 3D power Doppler (PD) ultrasound has been proposed for non-invasive approximation of perfusion. However, 3D-FMBV has never been applied in animals against a ground-truth.</p&g...

Szczegółowa specyfikacja

Opis bibliograficzny
Główni autorzy: Welsh, A, Fowlkes, B, Pinter, S, Ives, K, Owens, G, Rubin, J, Kripfgans, O, Looney, P, Collins, S, Stevenson, G
Format: Journal article
Język:English
Wydane: Radiological Society of North America 2019
Opis
Streszczenie:<p><strong>Background:</strong> Three-dimensional fractional moving blood volume (3D-FMBV) derived from 3D power Doppler (PD) ultrasound has been proposed for non-invasive approximation of perfusion. However, 3D-FMBV has never been applied in animals against a ground-truth.</p> <p><strong>Purpose:</strong> To determine the correlation between 3D-FMBV and the ‘gold-standard’ of fluorescent microspheres to measure renal perfusion in a porcine model.</p> <p><strong>Materials and Methods:</strong> From February 2017 to September 2017, adult pigs received an administration of fluorescent microspheres (FMS) before and after measurement of renal 3D-FMBV at baseline (100%) and approximately 75%, 50% and 25% flow levels using 2 different ultrasound machines (General Electric (GE), Philips). 3D PD ultrasound volumes were converted, segmented and correlations by simple linear regression (r2) were made between FMS and 3D-FMBV. Similarity and reproducibility of manual segmentation was determined by Dice similarity coefficient (DSC) and 3D-FMBV reproducibility (ICC).</p> <p><strong>Results: </strong> 13 pigs were studied with 33 flow measurements. Kidney volume (DSC = 0.89 ± 0.01) and renal segmentation (coefficient of variation = 12.6%; ICC = 0.86) were consistent. 3D-FMBV calculations had high reproducibility (ICC = 0.97 (95% CI = 0.96 - 0.98)). 3D-FMBV per-pig correlation showed excellent correlation for both GE and Philips ultrasound (GE mean r2 = 0.96, range = 0.92-1.0; Philips mean r2 = 0.93, range = 0.784 – 1.0). The correlation between 3D-FMBV and perfusion measured by microspheres was high (GE r2 = 0.80, p &lt; 0.001; Philips r2 = 0.70, p &lt; 0.001).</p> <p><strong>Conclusion:</strong> The strong correlation between 3D-FMBV and fluorescent microspheres indicates 3D-FMBV correlates to perfusion well and shows good reproducibility.</p>