DOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACE

The theory of collection efficiency measurements (under steady-state conditions) at double channel electrodes is extended to include the case where the species generated at the upstream electrode undergoes a heterogeneous reaction on the surface of the gap between the two electrodes. The problem is...

Full description

Bibliographic Details
Main Authors: Compton, R, Stearn, G, Unwin, P, Barwise, A
Format: Journal article
Language:English
Published: Kluwer Academic Publishers 1988
_version_ 1797057890059550720
author Compton, R
Stearn, G
Unwin, P
Barwise, A
author_facet Compton, R
Stearn, G
Unwin, P
Barwise, A
author_sort Compton, R
collection OXFORD
description The theory of collection efficiency measurements (under steady-state conditions) at double channel electrodes is extended to include the case where the species generated at the upstream electrode undergoes a heterogeneous reaction on the surface of the gap between the two electrodes. The problem is treated numerically using the Backwards Implicit method, which allows the collection efficiency to be related to the corresponding value of the rate constant for the heterogeneous process for chosen double electrode geometries and solution flow rates. The use of the technique is illustrated with experiments in which bromine, generated at the upstream electrode by the oxidation of bromide ions (in 0.5 M sulphuric acid), reacts with a cloth dyed with Direct Red 80, and is subsequently collected at the downstream electrode through transport-controlled reduction to bromide. Good agreement is found between theory and experiment. © 1988 Chapman and Hall Ltd.
first_indexed 2024-03-06T19:42:45Z
format Journal article
id oxford-uuid:2138d03b-80ae-4928-8938-50d8b161707e
institution University of Oxford
language English
last_indexed 2024-03-06T19:42:45Z
publishDate 1988
publisher Kluwer Academic Publishers
record_format dspace
spelling oxford-uuid:2138d03b-80ae-4928-8938-50d8b161707e2022-03-26T11:32:08ZDOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACEJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:2138d03b-80ae-4928-8938-50d8b161707eEnglishSymplectic Elements at OxfordKluwer Academic Publishers1988Compton, RStearn, GUnwin, PBarwise, AThe theory of collection efficiency measurements (under steady-state conditions) at double channel electrodes is extended to include the case where the species generated at the upstream electrode undergoes a heterogeneous reaction on the surface of the gap between the two electrodes. The problem is treated numerically using the Backwards Implicit method, which allows the collection efficiency to be related to the corresponding value of the rate constant for the heterogeneous process for chosen double electrode geometries and solution flow rates. The use of the technique is illustrated with experiments in which bromine, generated at the upstream electrode by the oxidation of bromide ions (in 0.5 M sulphuric acid), reacts with a cloth dyed with Direct Red 80, and is subsequently collected at the downstream electrode through transport-controlled reduction to bromide. Good agreement is found between theory and experiment. © 1988 Chapman and Hall Ltd.
spellingShingle Compton, R
Stearn, G
Unwin, P
Barwise, A
DOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACE
title DOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACE
title_full DOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACE
title_fullStr DOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACE
title_full_unstemmed DOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACE
title_short DOUBLE CHANNEL ELECTRODES AND THE MEASUREMENT OF HETEROGENEOUS REACTION-RATES AT THE SOLID LIQUID INTERFACE
title_sort double channel electrodes and the measurement of heterogeneous reaction rates at the solid liquid interface
work_keys_str_mv AT comptonr doublechannelelectrodesandthemeasurementofheterogeneousreactionratesatthesolidliquidinterface
AT stearng doublechannelelectrodesandthemeasurementofheterogeneousreactionratesatthesolidliquidinterface
AT unwinp doublechannelelectrodesandthemeasurementofheterogeneousreactionratesatthesolidliquidinterface
AT barwisea doublechannelelectrodesandthemeasurementofheterogeneousreactionratesatthesolidliquidinterface