Effects of sequential tungsten and helium ion implantation on nano-indentation hardness of tungsten

To simulate neutron and helium damage in a fusion reactor first wall sequential self-ion implantation up to 13 dpa followed by helium-ion implantation up to 3000 appm was performed to produce damaged layers of ∼2 μm depth in pure tungsten. The hardness of these layers was measured using nanoindentat...

Popoln opis

Bibliografske podrobnosti
Main Authors: Armstrong, D, Edmondson, P, Roberts, S
Format: Journal article
Izdano: AIP Publishing 2013
Opis
Izvleček:To simulate neutron and helium damage in a fusion reactor first wall sequential self-ion implantation up to 13 dpa followed by helium-ion implantation up to 3000 appm was performed to produce damaged layers of ∼2 μm depth in pure tungsten. The hardness of these layers was measured using nanoindentation and was studied using transmission electron microscopy. Substantial hardness increases were seen in helium implanted regions, with smaller hardness increases in regions which had already been self-ion implanted, thus, containing pre-existing dislocation loops. This suggests that, for the same helium content, helium trapped in distributed vacancies gives stronger hardening than helium trapped in vacancies condensed into dislocation loops.