Percutaneous fixation of scaphoid fractures. An anatomical study.
Percutaneous scaphoid fracture fixation has many advantages over the open method of fixation. We describe the anatomical basis for a safe percutaneous approach. Cannulated screws were inserted into 32 cadaveric scaphoids through 1 cm palmar incisions under fluoroscopic control. We then measured the...
Hlavní autoři: | Kamineni, S, Lavy, C |
---|---|
Médium: | Journal article |
Jazyk: | English |
Vydáno: |
1999
|
Podobné jednotky
-
Anatomic Locking Plate Fixation for Scaphoid Nonunion
Autor: Joshua Mirrer, a další
Vydáno: (2016-01-01) -
Median Nerve Injury Caused by Screw Malpositioning in Percutaneous Scaphoid Fracture Fixation
Autor: Marta Starnoni, MD, a další
Vydáno: (2019-06-01) -
Percutaneous Fixation without Bone Graft for Scaphoid Nonunion
Autor: João Carlos Belloti, a další
Vydáno: (2021-02-01) -
Scaphoid Fracture Fixation Leading Keys: Educational Corner
Autor: Amir Hosein Mafi, a další
Vydáno: (2022-04-01) -
Percutaneous treatment for waist and proximal pole scaphoid fractures
Autor: Antônio Lourenço Severo, a další