Effects of operating conditions on flow and heat transfer characteristics of mist cooling in a square ribbed channel

Flow and heat transfer characteristics of mist/steam cooling and mist/air cooling in a square channel with 60º rib angle are numerically investigated for a wide range of operating parameters, such as Reynolds number ranging from 10000 to 60000, reference pressure from 0.1 MPa to 0.5 MPa and inlet te...

Descrición completa

Detalles Bibliográficos
Main Authors: Gao, T, Zeng, J, Xia, Q, Li, J, Gong, J
Formato: Journal article
Publicado: SpringerNature 2017