Development of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment

<p>A measurement of the neutron electric dipole moment (nEDM) could hold the key to understanding why the visible universe is the way it is: why matter should predominate over antimatter. As a charge-parity violating (CPV) quantity, an nEDM could provide an insight into new mechanisms that add...

Full description

Bibliographic Details
Main Author: Cottle, A
Other Authors: Henry, S
Format: Thesis
Language:English
Published: 2015
Subjects:
_version_ 1797109564906143744
author Cottle, A
author2 Henry, S
author_facet Henry, S
Cottle, A
author_sort Cottle, A
collection OXFORD
description <p>A measurement of the neutron electric dipole moment (nEDM) could hold the key to understanding why the visible universe is the way it is: why matter should predominate over antimatter. As a charge-parity violating (CPV) quantity, an nEDM could provide an insight into new mechanisms that address this baryon asymmetry. The motivation for an improved sensitivity to an nEDM is to find it to be non-zero at a level consistent with certain beyond the Standard Model theories that predict new sources of CPV, or to establish a new limit that constrains them.</p></br> <p>CryoEDM is an experiment that sought to better the current limit of $|d_n| < 2.9 \times 10^{-26}\,e\,$cm by an order of magnitude. It is designed to measure the nEDM via the Ramsey Method of Separated Oscillatory Fields, in which it is critical that the magnetic field remains stable throughout. A way of accurately tracking the magnetic fields, moreover at a temperature $\sim 0.5\,$K, is crucial for CryoEDM, and for future cryogenic projects.</p></br> <p>This thesis presents work focussing on the development of a 12-SQUID magnetometry system for CryoEDM, that enables the magnetic field to be monitored to a precision of $0.1\,$pT. A major component of its infrastructure is the superconducting capillary shields, which screen the input lines of the SQUIDs from the pick up of spurious magnetic fields that will perturb a SQUID's measurement. These are shown to have a transverse shielding factor of $> 1 \times 10^{7}$, which is a few orders of magnitude greater than the calculated requirement.</p></br> <p>Efforts to characterise the shielding of the SQUID chips themselves are also discussed. The use of Cryoperm for shields reveals a tension between improved SQUID noise and worse neutron statistics. Investigations show that without it, SQUIDs have an elevated noise when cooled in a substantial magnetic field; with it, magnetostatic simulations suggest that it is detrimental to the polarisation of neutrons in transport. The findings suggest that with proper consideration, it is possible to reach a compromise between the two behaviours.</p></br> <p>Computational work to develop a simulation of SQUID data is detailed, which is based on the Laplace equation for the magnetic scalar potential. These data are ultimately used in the development of a linear regression technique to determine the volume-averaged magnetic field in the neutron cells. This proves highly effective in determining the fields within the $0.1\,$pT requirement under certain conditions.</p></br>
first_indexed 2024-03-07T07:43:30Z
format Thesis
id oxford-uuid:25c7b69a-7597-498b-a114-c4ef23a9ee70
institution University of Oxford
language English
last_indexed 2024-03-07T07:43:30Z
publishDate 2015
record_format dspace
spelling oxford-uuid:25c7b69a-7597-498b-a114-c4ef23a9ee702023-05-23T11:04:13ZDevelopment of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment Thesishttp://purl.org/coar/resource_type/c_db06uuid:25c7b69a-7597-498b-a114-c4ef23a9ee70Superconducting quantum interference devicesParticles (Nuclear physics)Dipole momentsEnglishHyrax Deposit2015Cottle, AHenry, SVan der Grinten, M<p>A measurement of the neutron electric dipole moment (nEDM) could hold the key to understanding why the visible universe is the way it is: why matter should predominate over antimatter. As a charge-parity violating (CPV) quantity, an nEDM could provide an insight into new mechanisms that address this baryon asymmetry. The motivation for an improved sensitivity to an nEDM is to find it to be non-zero at a level consistent with certain beyond the Standard Model theories that predict new sources of CPV, or to establish a new limit that constrains them.</p></br> <p>CryoEDM is an experiment that sought to better the current limit of $|d_n| < 2.9 \times 10^{-26}\,e\,$cm by an order of magnitude. It is designed to measure the nEDM via the Ramsey Method of Separated Oscillatory Fields, in which it is critical that the magnetic field remains stable throughout. A way of accurately tracking the magnetic fields, moreover at a temperature $\sim 0.5\,$K, is crucial for CryoEDM, and for future cryogenic projects.</p></br> <p>This thesis presents work focussing on the development of a 12-SQUID magnetometry system for CryoEDM, that enables the magnetic field to be monitored to a precision of $0.1\,$pT. A major component of its infrastructure is the superconducting capillary shields, which screen the input lines of the SQUIDs from the pick up of spurious magnetic fields that will perturb a SQUID's measurement. These are shown to have a transverse shielding factor of $> 1 \times 10^{7}$, which is a few orders of magnitude greater than the calculated requirement.</p></br> <p>Efforts to characterise the shielding of the SQUID chips themselves are also discussed. The use of Cryoperm for shields reveals a tension between improved SQUID noise and worse neutron statistics. Investigations show that without it, SQUIDs have an elevated noise when cooled in a substantial magnetic field; with it, magnetostatic simulations suggest that it is detrimental to the polarisation of neutrons in transport. The findings suggest that with proper consideration, it is possible to reach a compromise between the two behaviours.</p></br> <p>Computational work to develop a simulation of SQUID data is detailed, which is based on the Laplace equation for the magnetic scalar potential. These data are ultimately used in the development of a linear regression technique to determine the volume-averaged magnetic field in the neutron cells. This proves highly effective in determining the fields within the $0.1\,$pT requirement under certain conditions.</p></br>
spellingShingle Superconducting quantum interference devices
Particles (Nuclear physics)
Dipole moments
Cottle, A
Development of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment
title Development of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment
title_full Development of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment
title_fullStr Development of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment
title_full_unstemmed Development of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment
title_short Development of a SQUID magnetometry system for cryogenic neutron electric dipole moment experiment
title_sort development of a squid magnetometry system for cryogenic neutron electric dipole moment experiment
topic Superconducting quantum interference devices
Particles (Nuclear physics)
Dipole moments
work_keys_str_mv AT cottlea developmentofasquidmagnetometrysystemforcryogenicneutronelectricdipolemomentexperiment