The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
<p><strong>Objective</strong> To determine the reliability and validity of the Figure of 8 Walk test (F8W) for older people after knee replacement surgery in the home setting.</p> <p><strong>Design</strong> Observational repeated measures.</p> <p>...
主要な著者: | , , , |
---|---|
フォーマット: | Journal article |
出版事項: |
Elsevier
2018
|
_version_ | 1826263945462153216 |
---|---|
author | Barker, K Batting, M Schussel, M Newman, M |
author_facet | Barker, K Batting, M Schussel, M Newman, M |
author_sort | Barker, K |
collection | OXFORD |
description | <p><strong>Objective</strong> To determine the reliability and validity of the Figure of 8 Walk test (F8W) for older people after knee replacement surgery in the home setting.</p> <p><strong>Design</strong> Observational repeated measures.</p> <p><strong>Setting</strong> A specialist orthopaedic hospital and participants homes.</p> <p><strong>Participants</strong> Seventy-four older adults aged over 55 years one year following knee replacement surgery participated in two assessments more than one week apart.</p> <p><strong>Main Outcome Measure</strong> The time to complete, steps, boundary limits and smoothness score from the Figure of 8 Walk test (F8W), the time to complete the Timed Up and Go (TUG) test and the time to complete the Timed Walk Test (TWT).</p> <p><strong>Results</strong> Overall, on 95% of occasions, the difference between the measurements for intra-rater reliability were within 1.8 second of the two test times. The difference between the measurements for inter-rater reliability were found to be narrower than for intra-rater reliability with scores within 1.2 second overall on 95% of occasions. The time to perform the F8W was highly correlated to the Timed Up and Go (overall sample r = 0.921) and the variability spread within narrow limits (−0.8 to 0.8 z-scores). This was also true for the Timed Walk Test (overall sample r = 0.834) with a narrow limit of variability on almost all of the observations (−1.16 to 1.16 z-scores).</p> <p><strong>Conclusions</strong> The F8W test has good reliability and validity when used in either a clinical or home setting for patients around one year following knee replacement surgery.</p> |
first_indexed | 2024-03-06T19:59:56Z |
format | Journal article |
id | oxford-uuid:26ec98f2-96c6-478f-8d48-6bf6263c486e |
institution | University of Oxford |
last_indexed | 2024-03-06T19:59:56Z |
publishDate | 2018 |
publisher | Elsevier |
record_format | dspace |
spelling | oxford-uuid:26ec98f2-96c6-478f-8d48-6bf6263c486e2022-03-26T12:03:58ZThe reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:26ec98f2-96c6-478f-8d48-6bf6263c486eSymplectic Elements at OxfordElsevier2018Barker, KBatting, MSchussel, MNewman, M<p><strong>Objective</strong> To determine the reliability and validity of the Figure of 8 Walk test (F8W) for older people after knee replacement surgery in the home setting.</p> <p><strong>Design</strong> Observational repeated measures.</p> <p><strong>Setting</strong> A specialist orthopaedic hospital and participants homes.</p> <p><strong>Participants</strong> Seventy-four older adults aged over 55 years one year following knee replacement surgery participated in two assessments more than one week apart.</p> <p><strong>Main Outcome Measure</strong> The time to complete, steps, boundary limits and smoothness score from the Figure of 8 Walk test (F8W), the time to complete the Timed Up and Go (TUG) test and the time to complete the Timed Walk Test (TWT).</p> <p><strong>Results</strong> Overall, on 95% of occasions, the difference between the measurements for intra-rater reliability were within 1.8 second of the two test times. The difference between the measurements for inter-rater reliability were found to be narrower than for intra-rater reliability with scores within 1.2 second overall on 95% of occasions. The time to perform the F8W was highly correlated to the Timed Up and Go (overall sample r = 0.921) and the variability spread within narrow limits (−0.8 to 0.8 z-scores). This was also true for the Timed Walk Test (overall sample r = 0.834) with a narrow limit of variability on almost all of the observations (−1.16 to 1.16 z-scores).</p> <p><strong>Conclusions</strong> The F8W test has good reliability and validity when used in either a clinical or home setting for patients around one year following knee replacement surgery.</p> |
spellingShingle | Barker, K Batting, M Schussel, M Newman, M The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact? |
title | The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact? |
title_full | The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact? |
title_fullStr | The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact? |
title_full_unstemmed | The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact? |
title_short | The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact? |
title_sort | reliability and validity of the figure of 8 walk test in older people with knee replacement does the setting have an impact |
work_keys_str_mv | AT barkerk thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact AT battingm thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact AT schusselm thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact AT newmanm thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact AT barkerk reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact AT battingm reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact AT schusselm reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact AT newmanm reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact |