The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?

<p><strong>Objective</strong> To determine the reliability and validity of the Figure of 8 Walk test (F8W) for older people after knee replacement surgery in the home setting.</p> <p><strong>Design</strong> Observational repeated measures.</p> <p>...

詳細記述

書誌詳細
主要な著者: Barker, K, Batting, M, Schussel, M, Newman, M
フォーマット: Journal article
出版事項: Elsevier 2018
_version_ 1826263945462153216
author Barker, K
Batting, M
Schussel, M
Newman, M
author_facet Barker, K
Batting, M
Schussel, M
Newman, M
author_sort Barker, K
collection OXFORD
description <p><strong>Objective</strong> To determine the reliability and validity of the Figure of 8 Walk test (F8W) for older people after knee replacement surgery in the home setting.</p> <p><strong>Design</strong> Observational repeated measures.</p> <p><strong>Setting</strong> A specialist orthopaedic hospital and participants homes.</p> <p><strong>Participants</strong> Seventy-four older adults aged over 55 years one year following knee replacement surgery participated in two assessments more than one week apart.</p> <p><strong>Main Outcome Measure</strong> The time to complete, steps, boundary limits and smoothness score from the Figure of 8 Walk test (F8W), the time to complete the Timed Up and Go (TUG) test and the time to complete the Timed Walk Test (TWT).</p> <p><strong>Results</strong> Overall, on 95% of occasions, the difference between the measurements for intra-rater reliability were within 1.8 second of the two test times. The difference between the measurements for inter-rater reliability were found to be narrower than for intra-rater reliability with scores within 1.2 second overall on 95% of occasions. The time to perform the F8W was highly correlated to the Timed Up and Go (overall sample r = 0.921) and the variability spread within narrow limits (−0.8 to 0.8 z-scores). This was also true for the Timed Walk Test (overall sample r = 0.834) with a narrow limit of variability on almost all of the observations (−1.16 to 1.16 z-scores).</p> <p><strong>Conclusions</strong> The F8W test has good reliability and validity when used in either a clinical or home setting for patients around one year following knee replacement surgery.</p>
first_indexed 2024-03-06T19:59:56Z
format Journal article
id oxford-uuid:26ec98f2-96c6-478f-8d48-6bf6263c486e
institution University of Oxford
last_indexed 2024-03-06T19:59:56Z
publishDate 2018
publisher Elsevier
record_format dspace
spelling oxford-uuid:26ec98f2-96c6-478f-8d48-6bf6263c486e2022-03-26T12:03:58ZThe reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:26ec98f2-96c6-478f-8d48-6bf6263c486eSymplectic Elements at OxfordElsevier2018Barker, KBatting, MSchussel, MNewman, M<p><strong>Objective</strong> To determine the reliability and validity of the Figure of 8 Walk test (F8W) for older people after knee replacement surgery in the home setting.</p> <p><strong>Design</strong> Observational repeated measures.</p> <p><strong>Setting</strong> A specialist orthopaedic hospital and participants homes.</p> <p><strong>Participants</strong> Seventy-four older adults aged over 55 years one year following knee replacement surgery participated in two assessments more than one week apart.</p> <p><strong>Main Outcome Measure</strong> The time to complete, steps, boundary limits and smoothness score from the Figure of 8 Walk test (F8W), the time to complete the Timed Up and Go (TUG) test and the time to complete the Timed Walk Test (TWT).</p> <p><strong>Results</strong> Overall, on 95% of occasions, the difference between the measurements for intra-rater reliability were within 1.8 second of the two test times. The difference between the measurements for inter-rater reliability were found to be narrower than for intra-rater reliability with scores within 1.2 second overall on 95% of occasions. The time to perform the F8W was highly correlated to the Timed Up and Go (overall sample r = 0.921) and the variability spread within narrow limits (−0.8 to 0.8 z-scores). This was also true for the Timed Walk Test (overall sample r = 0.834) with a narrow limit of variability on almost all of the observations (−1.16 to 1.16 z-scores).</p> <p><strong>Conclusions</strong> The F8W test has good reliability and validity when used in either a clinical or home setting for patients around one year following knee replacement surgery.</p>
spellingShingle Barker, K
Batting, M
Schussel, M
Newman, M
The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
title The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
title_full The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
title_fullStr The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
title_full_unstemmed The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
title_short The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
title_sort reliability and validity of the figure of 8 walk test in older people with knee replacement does the setting have an impact
work_keys_str_mv AT barkerk thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact
AT battingm thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact
AT schusselm thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact
AT newmanm thereliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact
AT barkerk reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact
AT battingm reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact
AT schusselm reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact
AT newmanm reliabilityandvalidityofthefigureof8walktestinolderpeoplewithkneereplacementdoesthesettinghaveanimpact