Mixed-methods feasibility study of blood pressure self-screening for hypertension detection

<br/><strong>Objective: </strong>To assess the feasibility of using a blood pressure (BP) self-measurement kiosk – a solid-cuff sphygmomanometer combined with technology to integrate the BP readings into patient electronic medical records - to improve hypertension detection.<br/...

Full description

Bibliographic Details
Main Authors: Tompson, A, Fleming, S, Lee, M, Monaghan, M, Jowett, S, McCartney, D, Greenfield, S, Heneghan, C, Ward, A, Hobbs, F, McManus, R
Format: Journal article
Language:English
Published: BMJ Publishing Group 2019
_version_ 1797059209235267584
author Tompson, A
Fleming, S
Lee, M
Monaghan, M
Jowett, S
McCartney, D
Greenfield, S
Heneghan, C
Ward, A
Hobbs, F
McManus, R
author_facet Tompson, A
Fleming, S
Lee, M
Monaghan, M
Jowett, S
McCartney, D
Greenfield, S
Heneghan, C
Ward, A
Hobbs, F
McManus, R
author_sort Tompson, A
collection OXFORD
description <br/><strong>Objective: </strong>To assess the feasibility of using a blood pressure (BP) self-measurement kiosk – a solid-cuff sphygmomanometer combined with technology to integrate the BP readings into patient electronic medical records - to improve hypertension detection.<br/><strong>Design: </strong>A concurrent mixed-methods feasibility study incorporating observational and qualitative interview components.<br/><strong>Setting: </strong>Two English GP surgeries.<br/><strong>Participants: </strong>Adult patients registered at participating surgeries. Staff working at these sites.<br/><strong>Interventions: </strong>BP self-measurement kiosks were placed in the waiting rooms for a 12-month period between 2015-6 and compared to a 12-month control period prior to installation.<br/><strong>Outcome measures: </strong>A) The number of patients using the kiosk and agreeing to transfer of their data into their electronic medical records; B) the cost of using a kiosk compared to GP/practice nurse BP screening; C) qualitative themes regarding use of the equipment.<br/><strong>Results: </strong>Out of 15624 eligible patients, only 186 (1.2%, 95% confidence interval 1.0-1.4%) successfully used the kiosk to directly transfer a BP reading into their medical record. For a considerable portion of the intervention period, no readings were transferred, possibly indicating technical problems with the transfer link. A comparison of costs suggests that at least 52.6% of eligible patients would need to self-screen in order to bring costs below that of screening by GPs and practice nurses. Qualitative interviews confirmed that both patients and staff experienced technical difficulties, and used alternative methods to enter BP results into the medical record.<br/><strong>Conclusions: </strong>Whilst interviewees were generally positive about checking BP in the waiting room, the electronic transfer system as tested was neither robust, effective nor likely to be a cost-effective approach, thus may not be appropriate for a primary care environment. Since most of the cost of a kiosk system lies in the transfer mechanism, a solid-cuff sphygmomanometer and manual entry of results may be a suitable alternative.
first_indexed 2024-03-06T20:00:57Z
format Journal article
id oxford-uuid:27450bef-329a-48f9-ab72-90eb76b35a33
institution University of Oxford
language English
last_indexed 2024-03-06T20:00:57Z
publishDate 2019
publisher BMJ Publishing Group
record_format dspace
spelling oxford-uuid:27450bef-329a-48f9-ab72-90eb76b35a332022-03-26T12:06:03ZMixed-methods feasibility study of blood pressure self-screening for hypertension detectionJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:27450bef-329a-48f9-ab72-90eb76b35a33EnglishSymplectic Elements at OxfordBMJ Publishing Group2019Tompson, AFleming, SLee, MMonaghan, MJowett, SMcCartney, DGreenfield, SHeneghan, CWard, AHobbs, FMcManus, R<br/><strong>Objective: </strong>To assess the feasibility of using a blood pressure (BP) self-measurement kiosk – a solid-cuff sphygmomanometer combined with technology to integrate the BP readings into patient electronic medical records - to improve hypertension detection.<br/><strong>Design: </strong>A concurrent mixed-methods feasibility study incorporating observational and qualitative interview components.<br/><strong>Setting: </strong>Two English GP surgeries.<br/><strong>Participants: </strong>Adult patients registered at participating surgeries. Staff working at these sites.<br/><strong>Interventions: </strong>BP self-measurement kiosks were placed in the waiting rooms for a 12-month period between 2015-6 and compared to a 12-month control period prior to installation.<br/><strong>Outcome measures: </strong>A) The number of patients using the kiosk and agreeing to transfer of their data into their electronic medical records; B) the cost of using a kiosk compared to GP/practice nurse BP screening; C) qualitative themes regarding use of the equipment.<br/><strong>Results: </strong>Out of 15624 eligible patients, only 186 (1.2%, 95% confidence interval 1.0-1.4%) successfully used the kiosk to directly transfer a BP reading into their medical record. For a considerable portion of the intervention period, no readings were transferred, possibly indicating technical problems with the transfer link. A comparison of costs suggests that at least 52.6% of eligible patients would need to self-screen in order to bring costs below that of screening by GPs and practice nurses. Qualitative interviews confirmed that both patients and staff experienced technical difficulties, and used alternative methods to enter BP results into the medical record.<br/><strong>Conclusions: </strong>Whilst interviewees were generally positive about checking BP in the waiting room, the electronic transfer system as tested was neither robust, effective nor likely to be a cost-effective approach, thus may not be appropriate for a primary care environment. Since most of the cost of a kiosk system lies in the transfer mechanism, a solid-cuff sphygmomanometer and manual entry of results may be a suitable alternative.
spellingShingle Tompson, A
Fleming, S
Lee, M
Monaghan, M
Jowett, S
McCartney, D
Greenfield, S
Heneghan, C
Ward, A
Hobbs, F
McManus, R
Mixed-methods feasibility study of blood pressure self-screening for hypertension detection
title Mixed-methods feasibility study of blood pressure self-screening for hypertension detection
title_full Mixed-methods feasibility study of blood pressure self-screening for hypertension detection
title_fullStr Mixed-methods feasibility study of blood pressure self-screening for hypertension detection
title_full_unstemmed Mixed-methods feasibility study of blood pressure self-screening for hypertension detection
title_short Mixed-methods feasibility study of blood pressure self-screening for hypertension detection
title_sort mixed methods feasibility study of blood pressure self screening for hypertension detection
work_keys_str_mv AT tompsona mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT flemings mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT leem mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT monaghanm mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT jowetts mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT mccartneyd mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT greenfields mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT heneghanc mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT warda mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT hobbsf mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection
AT mcmanusr mixedmethodsfeasibilitystudyofbloodpressureselfscreeningforhypertensiondetection