Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis

Despite therapeutic advances, ischaemic stroke remains one of the leading causes of mortality and disability worldwide. Microbubble-enhanced sonothrombolysis is an advantageous method to accelerate the reopening of occluded arteries, but further improvements in safety and efficacy are required to at...

Descrición completa

Detalles Bibliográficos
Autor Principal: de Saint Victor, M
Outros autores: Coussios, C
Formato: Thesis
Idioma:English
Publicado: 2016
Subjects:
_version_ 1826316005508382720
author de Saint Victor, M
author2 Coussios, C
author_facet Coussios, C
de Saint Victor, M
author_sort de Saint Victor, M
collection OXFORD
description Despite therapeutic advances, ischaemic stroke remains one of the leading causes of mortality and disability worldwide. Microbubble-enhanced sonothrombolysis is an advantageous method to accelerate the reopening of occluded arteries, but further improvements in safety and efficacy are required to attain widespread clinical implementation. This thesis investigates the potential of magnetically targeted microbubbles to enhance sonothrombolysis. First, a computational and experimental model of a thrombosed vascular network was developed. It showed that magnetic targeting considerably increases the number of microbubbles delivered to the thrombus, a key element for effective sonothrombolysis. The effect of these magnetically targeted microbubbles on rates of thrombus breakdown was then investigated in vitro, first with ultrasound and microbubbles alone (mechanical sonothrombolysis), then with the addition of fibrinolytic drugs (enzymatic sonothrombolysis). Magnetic targeting was not found to affect mechanical treatment, and mechanical lysis rates were highly variable. On the other hand, magnetic targeting significantly accelerated enzymatic treatment, even with low concentrations of fibrinolytic drugs. The mechanisms underlying both treatments were discussed. In addition, treatment safety was examined. Specifically, the risk of secondary embolism and the feasibility of real-time treatment monitoring were assessed. Neither treatment increased the risk of downstream vascular embolism with large clot fragments. Acoustic monitoring of enzymatic sonothrombolysis was feasible, as a strong correlation was found between lysis rates and the energy of acoustic emissions near the clot surface. There was no strong correlation in mechanical sonothrombolysis. Magnetic targeting may therefore be regarded as a promising adjuvant to enzymatic sonothrombolysis, improving microbubble delivery to the clot, accelerating its breakdown, and reducing injected drug doses. It is hoped that targeted treatment and real-time monitoring will enhance safety and efficacy in the management of acute and chronic thrombosis, and ultimately improve patient outcomes.
first_indexed 2024-03-06T20:06:19Z
format Thesis
id oxford-uuid:290464d5-b0bb-4bfd-93b6-b4e86c0d65a8
institution University of Oxford
language English
last_indexed 2024-12-09T03:36:43Z
publishDate 2016
record_format dspace
spelling oxford-uuid:290464d5-b0bb-4bfd-93b6-b4e86c0d65a82024-12-01T20:01:00ZInvestigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysisThesishttp://purl.org/coar/resource_type/c_db06uuid:290464d5-b0bb-4bfd-93b6-b4e86c0d65a8Biomedical engineeringEnglishORA Deposit2016de Saint Victor, MCoussios, CStride, EDespite therapeutic advances, ischaemic stroke remains one of the leading causes of mortality and disability worldwide. Microbubble-enhanced sonothrombolysis is an advantageous method to accelerate the reopening of occluded arteries, but further improvements in safety and efficacy are required to attain widespread clinical implementation. This thesis investigates the potential of magnetically targeted microbubbles to enhance sonothrombolysis. First, a computational and experimental model of a thrombosed vascular network was developed. It showed that magnetic targeting considerably increases the number of microbubbles delivered to the thrombus, a key element for effective sonothrombolysis. The effect of these magnetically targeted microbubbles on rates of thrombus breakdown was then investigated in vitro, first with ultrasound and microbubbles alone (mechanical sonothrombolysis), then with the addition of fibrinolytic drugs (enzymatic sonothrombolysis). Magnetic targeting was not found to affect mechanical treatment, and mechanical lysis rates were highly variable. On the other hand, magnetic targeting significantly accelerated enzymatic treatment, even with low concentrations of fibrinolytic drugs. The mechanisms underlying both treatments were discussed. In addition, treatment safety was examined. Specifically, the risk of secondary embolism and the feasibility of real-time treatment monitoring were assessed. Neither treatment increased the risk of downstream vascular embolism with large clot fragments. Acoustic monitoring of enzymatic sonothrombolysis was feasible, as a strong correlation was found between lysis rates and the energy of acoustic emissions near the clot surface. There was no strong correlation in mechanical sonothrombolysis. Magnetic targeting may therefore be regarded as a promising adjuvant to enzymatic sonothrombolysis, improving microbubble delivery to the clot, accelerating its breakdown, and reducing injected drug doses. It is hoped that targeted treatment and real-time monitoring will enhance safety and efficacy in the management of acute and chronic thrombosis, and ultimately improve patient outcomes.
spellingShingle Biomedical engineering
de Saint Victor, M
Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis
title Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis
title_full Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis
title_fullStr Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis
title_full_unstemmed Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis
title_short Investigating magnetically targeted microbubbles for ultrasound-enhanced thrombolysis
title_sort investigating magnetically targeted microbubbles for ultrasound enhanced thrombolysis
topic Biomedical engineering
work_keys_str_mv AT desaintvictorm investigatingmagneticallytargetedmicrobubblesforultrasoundenhancedthrombolysis