External validation of inpatient neonatal mortality prediction models in high-mortality settings

<strong>Background<br></strong> Two neonatal mortality prediction models, the Neonatal Essential Treatment Score (NETS) which uses treatments prescribed at admission and the Score for Essential Neonatal Symptoms and Signs (SENSS) which uses basic clinical signs, were derived in hig...

Descripción completa

Detalles Bibliográficos
Autores principales: Tuti, T, Collins, G, English, M, Aluvaala, J
Otros Autores: Clinical Information Network
Formato: Journal article
Lenguaje:English
Publicado: BioMed Central 2022
_version_ 1826308332987613184
author Tuti, T
Collins, G
English, M
Aluvaala, J
author2 Clinical Information Network
author_facet Clinical Information Network
Tuti, T
Collins, G
English, M
Aluvaala, J
author_sort Tuti, T
collection OXFORD
description <strong>Background<br></strong> Two neonatal mortality prediction models, the Neonatal Essential Treatment Score (NETS) which uses treatments prescribed at admission and the Score for Essential Neonatal Symptoms and Signs (SENSS) which uses basic clinical signs, were derived in high-mortality, low-resource settings to utilise data more likely to be available in these settings. In this study, we evaluate the predictive accuracy of two neonatal prediction models for all-cause in-hospital mortality. <br><strong> Methods<br></strong> We used retrospectively collected routine clinical data recorded by duty clinicians at admission from 16 Kenyan hospitals used to externally validate and update the SENSS and NETS models that were initially developed from the data from the largest Kenyan maternity hospital to predict in-hospital mortality. Model performance was evaluated by assessing discrimination and calibration. Discrimination, the ability of the model to differentiate between those with and without the outcome, was measured using the c-statistic. Calibration, the agreement between predictions from the model and what was observed, was measured using the calibration intercept and slope (with values of 0 and 1 denoting perfect calibration). <br><strong> Results<br></strong> At initial external validation, the estimated mortality risks from the original SENSS and NETS models were markedly overestimated with calibration intercepts of − 0.703 (95% CI − 0.738 to − 0.669) and − 1.109 (95% CI − 1.148 to − 1.069) and too extreme with calibration slopes of 0.565 (95% CI 0.552 to 0.577) and 0.466 (95% CI 0.451 to 0.480), respectively. After model updating, the calibration of the model improved. The updated SENSS and NETS models had calibration intercepts of 0.311 (95% CI 0.282 to 0.350) and 0.032 (95% CI − 0.002 to 0.066) and calibration slopes of 1.029 (95% CI 1.006 to 1.051) and 0.799 (95% CI 0.774 to 0.823), respectively, while showing good discrimination with c-statistics of 0.834 (95% CI 0.829 to 0.839) and 0.775 (95% CI 0.768 to 0.782), respectively. The overall calibration performance of the updated SENSS and NETS models was better than any existing neonatal in-hospital mortality prediction models externally validated for settings comparable to Kenya. <br><strong> Conclusion<br></strong> Few prediction models undergo rigorous external validation. We show how external validation using data from multiple locations enables model updating and improving their performance and potential value. The improved models indicate it is possible to predict in-hospital mortality using either treatments or signs and symptoms derived from routine neonatal data from low-resource hospital settings also making possible their use for case-mix adjustment when contrasting similar hospital settings.
first_indexed 2024-03-07T07:17:57Z
format Journal article
id oxford-uuid:2ae17f46-87df-402d-9b1a-c2ebff691bd5
institution University of Oxford
language English
last_indexed 2024-03-07T07:17:57Z
publishDate 2022
publisher BioMed Central
record_format dspace
spelling oxford-uuid:2ae17f46-87df-402d-9b1a-c2ebff691bd52022-09-06T14:35:59ZExternal validation of inpatient neonatal mortality prediction models in high-mortality settingsJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:2ae17f46-87df-402d-9b1a-c2ebff691bd5EnglishSymplectic ElementsBioMed Central2022Tuti, TCollins, GEnglish, MAluvaala, JClinical Information Network<strong>Background<br></strong> Two neonatal mortality prediction models, the Neonatal Essential Treatment Score (NETS) which uses treatments prescribed at admission and the Score for Essential Neonatal Symptoms and Signs (SENSS) which uses basic clinical signs, were derived in high-mortality, low-resource settings to utilise data more likely to be available in these settings. In this study, we evaluate the predictive accuracy of two neonatal prediction models for all-cause in-hospital mortality. <br><strong> Methods<br></strong> We used retrospectively collected routine clinical data recorded by duty clinicians at admission from 16 Kenyan hospitals used to externally validate and update the SENSS and NETS models that were initially developed from the data from the largest Kenyan maternity hospital to predict in-hospital mortality. Model performance was evaluated by assessing discrimination and calibration. Discrimination, the ability of the model to differentiate between those with and without the outcome, was measured using the c-statistic. Calibration, the agreement between predictions from the model and what was observed, was measured using the calibration intercept and slope (with values of 0 and 1 denoting perfect calibration). <br><strong> Results<br></strong> At initial external validation, the estimated mortality risks from the original SENSS and NETS models were markedly overestimated with calibration intercepts of − 0.703 (95% CI − 0.738 to − 0.669) and − 1.109 (95% CI − 1.148 to − 1.069) and too extreme with calibration slopes of 0.565 (95% CI 0.552 to 0.577) and 0.466 (95% CI 0.451 to 0.480), respectively. After model updating, the calibration of the model improved. The updated SENSS and NETS models had calibration intercepts of 0.311 (95% CI 0.282 to 0.350) and 0.032 (95% CI − 0.002 to 0.066) and calibration slopes of 1.029 (95% CI 1.006 to 1.051) and 0.799 (95% CI 0.774 to 0.823), respectively, while showing good discrimination with c-statistics of 0.834 (95% CI 0.829 to 0.839) and 0.775 (95% CI 0.768 to 0.782), respectively. The overall calibration performance of the updated SENSS and NETS models was better than any existing neonatal in-hospital mortality prediction models externally validated for settings comparable to Kenya. <br><strong> Conclusion<br></strong> Few prediction models undergo rigorous external validation. We show how external validation using data from multiple locations enables model updating and improving their performance and potential value. The improved models indicate it is possible to predict in-hospital mortality using either treatments or signs and symptoms derived from routine neonatal data from low-resource hospital settings also making possible their use for case-mix adjustment when contrasting similar hospital settings.
spellingShingle Tuti, T
Collins, G
English, M
Aluvaala, J
External validation of inpatient neonatal mortality prediction models in high-mortality settings
title External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_full External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_fullStr External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_full_unstemmed External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_short External validation of inpatient neonatal mortality prediction models in high-mortality settings
title_sort external validation of inpatient neonatal mortality prediction models in high mortality settings
work_keys_str_mv AT tutit externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings
AT collinsg externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings
AT englishm externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings
AT aluvaalaj externalvalidationofinpatientneonatalmortalitypredictionmodelsinhighmortalitysettings