Sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy

The application of colourimetric cavity ringdown spectroscopy to the detection of trace compounds in water has been investigated using nitrite and iron(ii) as test analytes. Samples were contained within one of three commercially available flow cells ranging in optical path length from 0.1 mm to 2.0...

Celý popis

Podrobná bibliografie
Hlavní autoři: Rushworth, C, Yogarajah, Y, Zhao, Y, Morgan, H, Vallance, C
Médium: Journal article
Jazyk:English
Vydáno: Royal Society of Chemistry 2013
_version_ 1826264890946355200
author Rushworth, C
Yogarajah, Y
Zhao, Y
Morgan, H
Vallance, C
author_facet Rushworth, C
Yogarajah, Y
Zhao, Y
Morgan, H
Vallance, C
author_sort Rushworth, C
collection OXFORD
description The application of colourimetric cavity ringdown spectroscopy to the detection of trace compounds in water has been investigated using nitrite and iron(ii) as test analytes. Samples were contained within one of three commercially available flow cells ranging in optical path length from 0.1 mm to 2.0 mm, and positioned within a two-mirror ringdown cavity. A measurement of the decay rate of the intensity of an optical pulse introduced into the cavity allows an ultrasensitive determination of optical absorption by the sample. A calibration using the known absorption coefficient of potassium permanganate at 532 nm was first carried out in order to determine the detection sensitivity in terms of minimum detectable absorption per unit path length when using each flow cell. The detection of nitrite and iron was then carried out by using well-known colour reactions, namely the Griess reaction for nitrite and the bathophenanthroline method for iron(ii), to convert the analytes into strongly absorbing derivatives, which were quantified by a cavity ringdown measurement. In this first application of colourimetric cavity ringdown spectroscopy to the liquid phase, detection limits of 1.9 nM for nitrite and 3.8 nM for Fe(ii) were demonstrated in a flow cell of path length 1.0 mm. The volume of sample analysed is only 196 nL, so that detection limits of this order correspond to the detection of less than 1 billion molecules. The detection method is therefore suitable for integration into a microfluidic sensing platform. © 2013 The Royal Society of Chemistry.
first_indexed 2024-03-06T20:15:08Z
format Journal article
id oxford-uuid:2be413fc-b51c-4aae-9d64-23cc1b2ca8d3
institution University of Oxford
language English
last_indexed 2024-03-06T20:15:08Z
publishDate 2013
publisher Royal Society of Chemistry
record_format dspace
spelling oxford-uuid:2be413fc-b51c-4aae-9d64-23cc1b2ca8d32022-03-26T12:33:42ZSensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:2be413fc-b51c-4aae-9d64-23cc1b2ca8d3EnglishSymplectic Elements at OxfordRoyal Society of Chemistry2013Rushworth, CYogarajah, YZhao, YMorgan, HVallance, CThe application of colourimetric cavity ringdown spectroscopy to the detection of trace compounds in water has been investigated using nitrite and iron(ii) as test analytes. Samples were contained within one of three commercially available flow cells ranging in optical path length from 0.1 mm to 2.0 mm, and positioned within a two-mirror ringdown cavity. A measurement of the decay rate of the intensity of an optical pulse introduced into the cavity allows an ultrasensitive determination of optical absorption by the sample. A calibration using the known absorption coefficient of potassium permanganate at 532 nm was first carried out in order to determine the detection sensitivity in terms of minimum detectable absorption per unit path length when using each flow cell. The detection of nitrite and iron was then carried out by using well-known colour reactions, namely the Griess reaction for nitrite and the bathophenanthroline method for iron(ii), to convert the analytes into strongly absorbing derivatives, which were quantified by a cavity ringdown measurement. In this first application of colourimetric cavity ringdown spectroscopy to the liquid phase, detection limits of 1.9 nM for nitrite and 3.8 nM for Fe(ii) were demonstrated in a flow cell of path length 1.0 mm. The volume of sample analysed is only 196 nL, so that detection limits of this order correspond to the detection of less than 1 billion molecules. The detection method is therefore suitable for integration into a microfluidic sensing platform. © 2013 The Royal Society of Chemistry.
spellingShingle Rushworth, C
Yogarajah, Y
Zhao, Y
Morgan, H
Vallance, C
Sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy
title Sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy
title_full Sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy
title_fullStr Sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy
title_full_unstemmed Sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy
title_short Sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy
title_sort sensitive analysis of trace water analytes using colourimetric cavity ringdown spectroscopy
work_keys_str_mv AT rushworthc sensitiveanalysisoftracewateranalytesusingcolourimetriccavityringdownspectroscopy
AT yogarajahy sensitiveanalysisoftracewateranalytesusingcolourimetriccavityringdownspectroscopy
AT zhaoy sensitiveanalysisoftracewateranalytesusingcolourimetriccavityringdownspectroscopy
AT morganh sensitiveanalysisoftracewateranalytesusingcolourimetriccavityringdownspectroscopy
AT vallancec sensitiveanalysisoftracewateranalytesusingcolourimetriccavityringdownspectroscopy