A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.

The amplitude of the BOLD response to a stimulus is not only determined by changes in cerebral blood flow (CBF) and oxygen metabolism (CMRO(2)), but also by baseline physiological parameters such as haematocrit, oxygen extraction fraction (OEF) and blood volume. The calibrated BOLD approach aims to...

Full description

Bibliographic Details
Main Authors: Blockley, N, Griffeth, V, Buxton, R
Format: Journal article
Language:English
Published: 2012
_version_ 1797060928010715136
author Blockley, N
Griffeth, V
Buxton, R
author_facet Blockley, N
Griffeth, V
Buxton, R
author_sort Blockley, N
collection OXFORD
description The amplitude of the BOLD response to a stimulus is not only determined by changes in cerebral blood flow (CBF) and oxygen metabolism (CMRO(2)), but also by baseline physiological parameters such as haematocrit, oxygen extraction fraction (OEF) and blood volume. The calibrated BOLD approach aims to account for this physiological variation by performing an additional calibration scan. This calibration typically consists of a hypercapnia or hyperoxia respiratory challenge, although we propose that a measurement of the reversible transverse relaxation rate, R(2)', might also be used. A detailed model of the BOLD effect was used to simulate each of the calibration experiments, as well as the activation experiment, whilst varying a number of physiological parameters associated with the baseline state and response to activation. The effectiveness of the different calibration methods was considered by testing whether the BOLD response to activation scaled by the calibration parameter combined with the measured CBF provides sufficient information to reliably distinguish different levels of CMRO(2) response despite underlying physiological variability. In addition the effect of inaccuracies in the underlying assumptions of each technique were tested, e.g. isometabolism during hypercapnia. The three primary findings of the study were: 1) The new calibration method based on R(2)' worked reasonably well, although not as well as the ideal hypercapnia method; 2) The hyperoxia calibration method was significantly worse because baseline haematocrit and OEF must be assumed, and these physiological parameters have a significant effect on the measurements; and 3) the venous blood volume change with activation is an important confounding variable for all of the methods, with the hypercapnia method being the most robust when this is uncertain.
first_indexed 2024-03-06T20:23:49Z
format Journal article
id oxford-uuid:2eb90c8b-e3f4-4acd-8d96-bf7b8fb0b043
institution University of Oxford
language English
last_indexed 2024-03-06T20:23:49Z
publishDate 2012
record_format dspace
spelling oxford-uuid:2eb90c8b-e3f4-4acd-8d96-bf7b8fb0b0432022-03-26T12:50:42ZA general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:2eb90c8b-e3f4-4acd-8d96-bf7b8fb0b043EnglishSymplectic Elements at Oxford2012Blockley, NGriffeth, VBuxton, RThe amplitude of the BOLD response to a stimulus is not only determined by changes in cerebral blood flow (CBF) and oxygen metabolism (CMRO(2)), but also by baseline physiological parameters such as haematocrit, oxygen extraction fraction (OEF) and blood volume. The calibrated BOLD approach aims to account for this physiological variation by performing an additional calibration scan. This calibration typically consists of a hypercapnia or hyperoxia respiratory challenge, although we propose that a measurement of the reversible transverse relaxation rate, R(2)', might also be used. A detailed model of the BOLD effect was used to simulate each of the calibration experiments, as well as the activation experiment, whilst varying a number of physiological parameters associated with the baseline state and response to activation. The effectiveness of the different calibration methods was considered by testing whether the BOLD response to activation scaled by the calibration parameter combined with the measured CBF provides sufficient information to reliably distinguish different levels of CMRO(2) response despite underlying physiological variability. In addition the effect of inaccuracies in the underlying assumptions of each technique were tested, e.g. isometabolism during hypercapnia. The three primary findings of the study were: 1) The new calibration method based on R(2)' worked reasonably well, although not as well as the ideal hypercapnia method; 2) The hyperoxia calibration method was significantly worse because baseline haematocrit and OEF must be assumed, and these physiological parameters have a significant effect on the measurements; and 3) the venous blood volume change with activation is an important confounding variable for all of the methods, with the hypercapnia method being the most robust when this is uncertain.
spellingShingle Blockley, N
Griffeth, V
Buxton, R
A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.
title A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.
title_full A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.
title_fullStr A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.
title_full_unstemmed A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.
title_short A general analysis of calibrated BOLD methodology for measuring CMRO2 responses: comparison of a new approach with existing methods.
title_sort general analysis of calibrated bold methodology for measuring cmro2 responses comparison of a new approach with existing methods
work_keys_str_mv AT blockleyn ageneralanalysisofcalibratedboldmethodologyformeasuringcmro2responsescomparisonofanewapproachwithexistingmethods
AT griffethv ageneralanalysisofcalibratedboldmethodologyformeasuringcmro2responsescomparisonofanewapproachwithexistingmethods
AT buxtonr ageneralanalysisofcalibratedboldmethodologyformeasuringcmro2responsescomparisonofanewapproachwithexistingmethods
AT blockleyn generalanalysisofcalibratedboldmethodologyformeasuringcmro2responsescomparisonofanewapproachwithexistingmethods
AT griffethv generalanalysisofcalibratedboldmethodologyformeasuringcmro2responsescomparisonofanewapproachwithexistingmethods
AT buxtonr generalanalysisofcalibratedboldmethodologyformeasuringcmro2responsescomparisonofanewapproachwithexistingmethods