Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.

Background: Targeted next generation sequencing (NGS) panels are increasingly being used in clinical genomics to increase capacity, throughput and affordability of gene testing. Identifying whole exon deletions or duplications (termed exon copy number variants, ‘exon CNVs’) in exon-targeted NGS pane...

Cur síos iomlán

Sonraí bibleagrafaíochta
Príomhchruthaitheoirí: Fowler, A, Mahamdallie, S, Ruark, E, Seal, S, Ramsay, E, Clarke, M, Uddin, I, Wylie, H, Strydom, A, Lunter, G, Rahman, N
Formáid: Journal article
Teanga:English
Foilsithe / Cruthaithe: F1000Research 2016
_version_ 1826266366026448896
author Fowler, A
Mahamdallie, S
Ruark, E
Seal, S
Ramsay, E
Clarke, M
Uddin, I
Wylie, H
Strydom, A
Lunter, G
Rahman, N
author_facet Fowler, A
Mahamdallie, S
Ruark, E
Seal, S
Ramsay, E
Clarke, M
Uddin, I
Wylie, H
Strydom, A
Lunter, G
Rahman, N
author_sort Fowler, A
collection OXFORD
description Background: Targeted next generation sequencing (NGS) panels are increasingly being used in clinical genomics to increase capacity, throughput and affordability of gene testing. Identifying whole exon deletions or duplications (termed exon copy number variants, ‘exon CNVs’) in exon-targeted NGS panels has proved challenging, particularly for single exon CNVs. <br/><br/> Methods: We developed a tool for the Detection of Exon Copy Number variants (DECoN), which is optimised for analysis of exon-targeted NGS panels in the clinical setting. We evaluated DECoN performance using 96 samples with independently validated exon CNV data. We performed simulations to evaluate DECoN detection performance of single exon CNVs and to evaluate performance using different coverage levels and sample numbers. Finally, we implemented DECoN in a clinical laboratory that tests BRCA1 and BRCA2 with the TruSight Cancer Panel (TSCP). We used DECoN to analyse 1,919 samples, validating exon CNV detections by multiplex ligation-dependent probe amplification (MLPA). <br/><br/> Results: In the evaluation set, DECoN achieved 100% sensitivity and 99% specificity for BRCA exon CNVs, including identification of 8 single exon CNVs. DECoN also identified 14/15 exon CNVs in 8 other genes. Simulations of all possible BRCA single exon CNVs gave a mean sensitivity of 98% for deletions and 95% for duplications. DECoN performance remained excellent with different levels of coverage and sample numbers; sensitivity and specificity was &gt;98% with the typical NGS run parameters. In the clinical pipeline, DECoN automatically analyses pools of 48 samples at a time, taking 24 minutes per pool, on average. DECoN detected 24 BRCA exon CNVs, of which 23 were confirmed by MLPA, giving a false discovery rate of 4%. Specificity was 99.7%. <br/><br/> Conclusions: DECoN is a fast, accurate, exon CNV detection tool readily implementable in research and clinical NGS pipelines. It has high sensitivity and specificity and acceptable false discovery rate. DECoN is freely available at www.icr.ac.uk/decon.
first_indexed 2024-03-06T20:37:49Z
format Journal article
id oxford-uuid:3337d4e4-25e0-42e4-ae02-ed5c55e41a0e
institution University of Oxford
language English
last_indexed 2024-03-06T20:37:49Z
publishDate 2016
publisher F1000Research
record_format dspace
spelling oxford-uuid:3337d4e4-25e0-42e4-ae02-ed5c55e41a0e2022-03-26T13:19:02ZAccurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:3337d4e4-25e0-42e4-ae02-ed5c55e41a0eEnglishSymplectic Elements at OxfordF1000Research2016Fowler, AMahamdallie, SRuark, ESeal, SRamsay, EClarke, MUddin, IWylie, HStrydom, ALunter, GRahman, NBackground: Targeted next generation sequencing (NGS) panels are increasingly being used in clinical genomics to increase capacity, throughput and affordability of gene testing. Identifying whole exon deletions or duplications (termed exon copy number variants, ‘exon CNVs’) in exon-targeted NGS panels has proved challenging, particularly for single exon CNVs. <br/><br/> Methods: We developed a tool for the Detection of Exon Copy Number variants (DECoN), which is optimised for analysis of exon-targeted NGS panels in the clinical setting. We evaluated DECoN performance using 96 samples with independently validated exon CNV data. We performed simulations to evaluate DECoN detection performance of single exon CNVs and to evaluate performance using different coverage levels and sample numbers. Finally, we implemented DECoN in a clinical laboratory that tests BRCA1 and BRCA2 with the TruSight Cancer Panel (TSCP). We used DECoN to analyse 1,919 samples, validating exon CNV detections by multiplex ligation-dependent probe amplification (MLPA). <br/><br/> Results: In the evaluation set, DECoN achieved 100% sensitivity and 99% specificity for BRCA exon CNVs, including identification of 8 single exon CNVs. DECoN also identified 14/15 exon CNVs in 8 other genes. Simulations of all possible BRCA single exon CNVs gave a mean sensitivity of 98% for deletions and 95% for duplications. DECoN performance remained excellent with different levels of coverage and sample numbers; sensitivity and specificity was &gt;98% with the typical NGS run parameters. In the clinical pipeline, DECoN automatically analyses pools of 48 samples at a time, taking 24 minutes per pool, on average. DECoN detected 24 BRCA exon CNVs, of which 23 were confirmed by MLPA, giving a false discovery rate of 4%. Specificity was 99.7%. <br/><br/> Conclusions: DECoN is a fast, accurate, exon CNV detection tool readily implementable in research and clinical NGS pipelines. It has high sensitivity and specificity and acceptable false discovery rate. DECoN is freely available at www.icr.ac.uk/decon.
spellingShingle Fowler, A
Mahamdallie, S
Ruark, E
Seal, S
Ramsay, E
Clarke, M
Uddin, I
Wylie, H
Strydom, A
Lunter, G
Rahman, N
Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
title Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
title_full Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
title_fullStr Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
title_full_unstemmed Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
title_short Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
title_sort accurate clinical detection of exon copy number variants in a targeted ngs panel using decon
work_keys_str_mv AT fowlera accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT mahamdallies accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT ruarke accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT seals accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT ramsaye accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT clarkem accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT uddini accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT wylieh accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT strydoma accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT lunterg accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon
AT rahmann accurateclinicaldetectionofexoncopynumbervariantsinatargetedngspanelusingdecon