The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.
BACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (U...
Main Authors: | , , , , , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
2015
|
_version_ | 1797062655673892864 |
---|---|
author | Glyn-Jones, S Thomas, G Garfjeld-Roberts, P Gundle, R Taylor, A McLardy-Smith, P Murray, D |
author_facet | Glyn-Jones, S Thomas, G Garfjeld-Roberts, P Gundle, R Taylor, A McLardy-Smith, P Murray, D |
author_sort | Glyn-Jones, S |
collection | OXFORD |
description | BACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (UHMWPE). However, there are few long-term data to support its use. QUESTIONS/PURPOSES: The aim of this study was to measure the long-term steady-state wear of HXLPE compared with UHMWPE liners in a prospective, double-blind, randomized controlled trial using radiostereometric analysis. METHODS: Fifty-four patients were randomized to receive hip arthroplasties with either UHMWPE liners or HXLPE liners. Complete followup was available on 39 of these patients (72%). All patients received the same cemented stem and an uncemented acetabular component. Three-dimensional penetration of the head into the socket was determined at 10 years using a radiostereometric analysis system, which has an in vivo accuracy of <0.1 mm. Oxford Hip Scores were compared between the groups. RESULTS: At 10 years there was significantly less wear of HXLPE (0.003 mm/year; 95% confidence interval [CI], ±0.010; SD 0.023; range, -0.057 to 0.074) compared with UHMWPE (0.030 mm/year; 95% CI, ±0.012; p<0.001; SD 0.0.27; range, -0.001 to 0.164). The volumetric penetration from 1 to 10 years for the UHMWPE group was 98 mm3 (95% CI, ±46 mm3; SD 102 mm3; range, -4 to 430 mm3) compared with 14 mm3 (95% CI, ±40 mm3; SD 91 mm3; range, -189 to 242 mm3) for the HXLPE group (p=0.01). CONCLUSIONS: This study demonstrates that HXLPE has little detectable steady-state in vivo wear. This may result in fewer reoperations from loosening; however, careful clinical followup into the second decade still needs to be performed. LEVEL OF EVIDENCE: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. |
first_indexed | 2024-03-06T20:48:39Z |
format | Journal article |
id | oxford-uuid:36cf6d34-d690-4f68-b2f7-71ded32b5c66 |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-06T20:48:39Z |
publishDate | 2015 |
record_format | dspace |
spelling | oxford-uuid:36cf6d34-d690-4f68-b2f7-71ded32b5c662022-03-26T13:40:11ZThe John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:36cf6d34-d690-4f68-b2f7-71ded32b5c66EnglishSymplectic Elements at Oxford2015Glyn-Jones, SThomas, GGarfjeld-Roberts, PGundle, RTaylor, AMcLardy-Smith, PMurray, DBACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (UHMWPE). However, there are few long-term data to support its use. QUESTIONS/PURPOSES: The aim of this study was to measure the long-term steady-state wear of HXLPE compared with UHMWPE liners in a prospective, double-blind, randomized controlled trial using radiostereometric analysis. METHODS: Fifty-four patients were randomized to receive hip arthroplasties with either UHMWPE liners or HXLPE liners. Complete followup was available on 39 of these patients (72%). All patients received the same cemented stem and an uncemented acetabular component. Three-dimensional penetration of the head into the socket was determined at 10 years using a radiostereometric analysis system, which has an in vivo accuracy of <0.1 mm. Oxford Hip Scores were compared between the groups. RESULTS: At 10 years there was significantly less wear of HXLPE (0.003 mm/year; 95% confidence interval [CI], ±0.010; SD 0.023; range, -0.057 to 0.074) compared with UHMWPE (0.030 mm/year; 95% CI, ±0.012; p<0.001; SD 0.0.27; range, -0.001 to 0.164). The volumetric penetration from 1 to 10 years for the UHMWPE group was 98 mm3 (95% CI, ±46 mm3; SD 102 mm3; range, -4 to 430 mm3) compared with 14 mm3 (95% CI, ±40 mm3; SD 91 mm3; range, -189 to 242 mm3) for the HXLPE group (p=0.01). CONCLUSIONS: This study demonstrates that HXLPE has little detectable steady-state in vivo wear. This may result in fewer reoperations from loosening; however, careful clinical followup into the second decade still needs to be performed. LEVEL OF EVIDENCE: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. |
spellingShingle | Glyn-Jones, S Thomas, G Garfjeld-Roberts, P Gundle, R Taylor, A McLardy-Smith, P Murray, D The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. |
title | The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. |
title_full | The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. |
title_fullStr | The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. |
title_full_unstemmed | The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. |
title_short | The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial. |
title_sort | john charnley award highly crosslinked polyethylene in total hip arthroplasty decreases long term wear a double blind randomized trial |
work_keys_str_mv | AT glynjoness thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT thomasg thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT garfjeldrobertsp thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT gundler thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT taylora thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT mclardysmithp thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT murrayd thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT glynjoness johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT thomasg johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT garfjeldrobertsp johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT gundler johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT taylora johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT mclardysmithp johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial AT murrayd johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial |