The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.

BACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (U...

Full description

Bibliographic Details
Main Authors: Glyn-Jones, S, Thomas, G, Garfjeld-Roberts, P, Gundle, R, Taylor, A, McLardy-Smith, P, Murray, D
Format: Journal article
Language:English
Published: 2015
_version_ 1797062655673892864
author Glyn-Jones, S
Thomas, G
Garfjeld-Roberts, P
Gundle, R
Taylor, A
McLardy-Smith, P
Murray, D
author_facet Glyn-Jones, S
Thomas, G
Garfjeld-Roberts, P
Gundle, R
Taylor, A
McLardy-Smith, P
Murray, D
author_sort Glyn-Jones, S
collection OXFORD
description BACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (UHMWPE). However, there are few long-term data to support its use. QUESTIONS/PURPOSES: The aim of this study was to measure the long-term steady-state wear of HXLPE compared with UHMWPE liners in a prospective, double-blind, randomized controlled trial using radiostereometric analysis. METHODS: Fifty-four patients were randomized to receive hip arthroplasties with either UHMWPE liners or HXLPE liners. Complete followup was available on 39 of these patients (72%). All patients received the same cemented stem and an uncemented acetabular component. Three-dimensional penetration of the head into the socket was determined at 10 years using a radiostereometric analysis system, which has an in vivo accuracy of <0.1 mm. Oxford Hip Scores were compared between the groups. RESULTS: At 10 years there was significantly less wear of HXLPE (0.003 mm/year; 95% confidence interval [CI], ±0.010; SD 0.023; range, -0.057 to 0.074) compared with UHMWPE (0.030 mm/year; 95% CI, ±0.012; p<0.001; SD 0.0.27; range, -0.001 to 0.164). The volumetric penetration from 1 to 10 years for the UHMWPE group was 98 mm3 (95% CI, ±46 mm3; SD 102 mm3; range, -4 to 430 mm3) compared with 14 mm3 (95% CI, ±40 mm3; SD 91 mm3; range, -189 to 242 mm3) for the HXLPE group (p=0.01). CONCLUSIONS: This study demonstrates that HXLPE has little detectable steady-state in vivo wear. This may result in fewer reoperations from loosening; however, careful clinical followup into the second decade still needs to be performed. LEVEL OF EVIDENCE: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
first_indexed 2024-03-06T20:48:39Z
format Journal article
id oxford-uuid:36cf6d34-d690-4f68-b2f7-71ded32b5c66
institution University of Oxford
language English
last_indexed 2024-03-06T20:48:39Z
publishDate 2015
record_format dspace
spelling oxford-uuid:36cf6d34-d690-4f68-b2f7-71ded32b5c662022-03-26T13:40:11ZThe John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:36cf6d34-d690-4f68-b2f7-71ded32b5c66EnglishSymplectic Elements at Oxford2015Glyn-Jones, SThomas, GGarfjeld-Roberts, PGundle, RTaylor, AMcLardy-Smith, PMurray, DBACKGROUND: The use of highly crosslinked polyethylene (HXLPE) is now commonplace for total hip arthroplasty. Hip simulator studies and short-term in vivo measurements suggest that the wear rate of some types of HXLPE is significantly less than conventional ultrahigh-molecular-weight polyethylene (UHMWPE). However, there are few long-term data to support its use. QUESTIONS/PURPOSES: The aim of this study was to measure the long-term steady-state wear of HXLPE compared with UHMWPE liners in a prospective, double-blind, randomized controlled trial using radiostereometric analysis. METHODS: Fifty-four patients were randomized to receive hip arthroplasties with either UHMWPE liners or HXLPE liners. Complete followup was available on 39 of these patients (72%). All patients received the same cemented stem and an uncemented acetabular component. Three-dimensional penetration of the head into the socket was determined at 10 years using a radiostereometric analysis system, which has an in vivo accuracy of <0.1 mm. Oxford Hip Scores were compared between the groups. RESULTS: At 10 years there was significantly less wear of HXLPE (0.003 mm/year; 95% confidence interval [CI], ±0.010; SD 0.023; range, -0.057 to 0.074) compared with UHMWPE (0.030 mm/year; 95% CI, ±0.012; p<0.001; SD 0.0.27; range, -0.001 to 0.164). The volumetric penetration from 1 to 10 years for the UHMWPE group was 98 mm3 (95% CI, ±46 mm3; SD 102 mm3; range, -4 to 430 mm3) compared with 14 mm3 (95% CI, ±40 mm3; SD 91 mm3; range, -189 to 242 mm3) for the HXLPE group (p=0.01). CONCLUSIONS: This study demonstrates that HXLPE has little detectable steady-state in vivo wear. This may result in fewer reoperations from loosening; however, careful clinical followup into the second decade still needs to be performed. LEVEL OF EVIDENCE: Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
spellingShingle Glyn-Jones, S
Thomas, G
Garfjeld-Roberts, P
Gundle, R
Taylor, A
McLardy-Smith, P
Murray, D
The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.
title The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.
title_full The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.
title_fullStr The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.
title_full_unstemmed The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.
title_short The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.
title_sort john charnley award highly crosslinked polyethylene in total hip arthroplasty decreases long term wear a double blind randomized trial
work_keys_str_mv AT glynjoness thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT thomasg thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT garfjeldrobertsp thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT gundler thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT taylora thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT mclardysmithp thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT murrayd thejohncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT glynjoness johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT thomasg johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT garfjeldrobertsp johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT gundler johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT taylora johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT mclardysmithp johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial
AT murrayd johncharnleyawardhighlycrosslinkedpolyethyleneintotalhiparthroplastydecreaseslongtermwearadoubleblindrandomizedtrial