The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.

To improve preservation of donor livers, we have developed a portable hypothermic machine perfusion (HMP) system as an alternative for static cold storage. A prototype of the system was built and evaluated on functionality. Evaluation criteria included 24 h of adequate pressure controlled perfusion,...

Full description

Bibliographic Details
Main Authors: van der Plaats, A, Maathuis, M, 'T Hart, N, Bellekom, A, Hofker, H, van der Houwen, E, Verkerke, G, Leuvenink, H, Verdonck, P, Ploeg, R, Rakhorst, G
Format: Journal article
Language:English
Published: 2006
_version_ 1826267159767023616
author van der Plaats, A
Maathuis, M
'T Hart, N
Bellekom, A
Hofker, H
van der Houwen, E
Verkerke, G
Leuvenink, H
Verdonck, P
Ploeg, R
Rakhorst, G
author_facet van der Plaats, A
Maathuis, M
'T Hart, N
Bellekom, A
Hofker, H
van der Houwen, E
Verkerke, G
Leuvenink, H
Verdonck, P
Ploeg, R
Rakhorst, G
author_sort van der Plaats, A
collection OXFORD
description To improve preservation of donor livers, we have developed a portable hypothermic machine perfusion (HMP) system as an alternative for static cold storage. A prototype of the system was built and evaluated on functionality. Evaluation criteria included 24 h of adequate pressure controlled perfusion, sufficient oxygenation, a maintained 0-4 degrees C temperature and sterile conditions. Porcine livers were perfused with pump pressures that were set at 4 mmHg (continuous, portal vein) and 30/20 mmHg, at 60 BPM (pulsatile, hepatic artery). Control livers were preserved using the clinical golden standard: static cold storage. In the HMP group, pressure, flow and temperature were continuously monitored for 24 h. At time-points t = 0, 2, 4, 8, 12, and 24 h samples of University of Wisconsin machine preservation solution were taken for measurement of partial oxygen pressure (pO(2)) and lacto-dehydrogenase. Biopsies in every lobe were taken for histology and electron microscopy; samples of ice, preservation solution, liver surface, and bile were taken and cultured to determine sterility. Results showed that temperature was maintained at 0-4 degrees C; perfusion pressure was maintained at 4 mmHg and 30/20 mmHg for portal vein and hepatic artery, respectively. Flow was approximately 350 and 80 ml/min, respectively, but decreased in the portal vein, probably due to edema formation. Arterial pO(2) was kept at 100 kPa. Histology showed complete perfusion of the liver with no major damage to hepatocytes, bile ducts, and non-parenchymal cells compared to control livers. The machine perfusion system complied to the design criteria and will have to demonstrate the superiority of machine perfusion over cold storage in transplant experiments.
first_indexed 2024-03-06T20:49:57Z
format Journal article
id oxford-uuid:373c3e4c-71f8-4f06-952b-09f765460e05
institution University of Oxford
language English
last_indexed 2024-03-06T20:49:57Z
publishDate 2006
record_format dspace
spelling oxford-uuid:373c3e4c-71f8-4f06-952b-09f765460e052022-03-26T13:42:47ZThe Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:373c3e4c-71f8-4f06-952b-09f765460e05EnglishSymplectic Elements at Oxford2006van der Plaats, AMaathuis, M'T Hart, NBellekom, AHofker, Hvan der Houwen, EVerkerke, GLeuvenink, HVerdonck, PPloeg, RRakhorst, GTo improve preservation of donor livers, we have developed a portable hypothermic machine perfusion (HMP) system as an alternative for static cold storage. A prototype of the system was built and evaluated on functionality. Evaluation criteria included 24 h of adequate pressure controlled perfusion, sufficient oxygenation, a maintained 0-4 degrees C temperature and sterile conditions. Porcine livers were perfused with pump pressures that were set at 4 mmHg (continuous, portal vein) and 30/20 mmHg, at 60 BPM (pulsatile, hepatic artery). Control livers were preserved using the clinical golden standard: static cold storage. In the HMP group, pressure, flow and temperature were continuously monitored for 24 h. At time-points t = 0, 2, 4, 8, 12, and 24 h samples of University of Wisconsin machine preservation solution were taken for measurement of partial oxygen pressure (pO(2)) and lacto-dehydrogenase. Biopsies in every lobe were taken for histology and electron microscopy; samples of ice, preservation solution, liver surface, and bile were taken and cultured to determine sterility. Results showed that temperature was maintained at 0-4 degrees C; perfusion pressure was maintained at 4 mmHg and 30/20 mmHg for portal vein and hepatic artery, respectively. Flow was approximately 350 and 80 ml/min, respectively, but decreased in the portal vein, probably due to edema formation. Arterial pO(2) was kept at 100 kPa. Histology showed complete perfusion of the liver with no major damage to hepatocytes, bile ducts, and non-parenchymal cells compared to control livers. The machine perfusion system complied to the design criteria and will have to demonstrate the superiority of machine perfusion over cold storage in transplant experiments.
spellingShingle van der Plaats, A
Maathuis, M
'T Hart, N
Bellekom, A
Hofker, H
van der Houwen, E
Verkerke, G
Leuvenink, H
Verdonck, P
Ploeg, R
Rakhorst, G
The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.
title The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.
title_full The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.
title_fullStr The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.
title_full_unstemmed The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.
title_short The Groningen hypothermic liver perfusion pump: functional evaluation of a new machine perfusion system.
title_sort groningen hypothermic liver perfusion pump functional evaluation of a new machine perfusion system
work_keys_str_mv AT vanderplaatsa thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT maathuism thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT thartn thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT bellekoma thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT hofkerh thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT vanderhouwene thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT verkerkeg thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT leuveninkh thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT verdonckp thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT ploegr thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT rakhorstg thegroningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT vanderplaatsa groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT maathuism groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT thartn groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT bellekoma groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT hofkerh groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT vanderhouwene groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT verkerkeg groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT leuveninkh groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT verdonckp groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT ploegr groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem
AT rakhorstg groningenhypothermicliverperfusionpumpfunctionalevaluationofanewmachineperfusionsystem