A fully integrated multi-channel detector for electron spectroscopy

In electron spectroscopy, multi-channel detection combined with intense radiation sources provides the optimum experimental configuration. Building on the 5 mm, 192-channel ion detector developed at Aberystwyth, longer arrays have been fabricated for the detection of electrons in a commercial hemisp...

Full description

Bibliographic Details
Main Authors: Langstaff, D, Bushell, A, Chase, T, Evans, D
Format: Journal article
Language:English
Published: 2005
_version_ 1797063117600980992
author Langstaff, D
Bushell, A
Chase, T
Evans, D
author_facet Langstaff, D
Bushell, A
Chase, T
Evans, D
author_sort Langstaff, D
collection OXFORD
description In electron spectroscopy, multi-channel detection combined with intense radiation sources provides the optimum experimental configuration. Building on the 5 mm, 192-channel ion detector developed at Aberystwyth, longer arrays have been fabricated for the detection of electrons in a commercial hemispherical analyser. The performance and reliability of a 10 mm, 384-detector array is discussed and the first array-detected photoelectron spectroscopy data for single-crystal diamond are presented. In scanning mode, the detector shows a large improvement compared to single channeltron detection and this improvement allows data to be collected in snapshot mode (1 s per spectrum) to enable real-time measurements. © 2005 Elsevier B.V. All rights reserved.
first_indexed 2024-03-06T20:55:15Z
format Journal article
id oxford-uuid:390252d7-d2dd-45e8-929d-7aad727319d8
institution University of Oxford
language English
last_indexed 2024-03-06T20:55:15Z
publishDate 2005
record_format dspace
spelling oxford-uuid:390252d7-d2dd-45e8-929d-7aad727319d82022-03-26T13:53:10ZA fully integrated multi-channel detector for electron spectroscopyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:390252d7-d2dd-45e8-929d-7aad727319d8EnglishSymplectic Elements at Oxford2005Langstaff, DBushell, AChase, TEvans, DIn electron spectroscopy, multi-channel detection combined with intense radiation sources provides the optimum experimental configuration. Building on the 5 mm, 192-channel ion detector developed at Aberystwyth, longer arrays have been fabricated for the detection of electrons in a commercial hemispherical analyser. The performance and reliability of a 10 mm, 384-detector array is discussed and the first array-detected photoelectron spectroscopy data for single-crystal diamond are presented. In scanning mode, the detector shows a large improvement compared to single channeltron detection and this improvement allows data to be collected in snapshot mode (1 s per spectrum) to enable real-time measurements. © 2005 Elsevier B.V. All rights reserved.
spellingShingle Langstaff, D
Bushell, A
Chase, T
Evans, D
A fully integrated multi-channel detector for electron spectroscopy
title A fully integrated multi-channel detector for electron spectroscopy
title_full A fully integrated multi-channel detector for electron spectroscopy
title_fullStr A fully integrated multi-channel detector for electron spectroscopy
title_full_unstemmed A fully integrated multi-channel detector for electron spectroscopy
title_short A fully integrated multi-channel detector for electron spectroscopy
title_sort fully integrated multi channel detector for electron spectroscopy
work_keys_str_mv AT langstaffd afullyintegratedmultichanneldetectorforelectronspectroscopy
AT bushella afullyintegratedmultichanneldetectorforelectronspectroscopy
AT chaset afullyintegratedmultichanneldetectorforelectronspectroscopy
AT evansd afullyintegratedmultichanneldetectorforelectronspectroscopy
AT langstaffd fullyintegratedmultichanneldetectorforelectronspectroscopy
AT bushella fullyintegratedmultichanneldetectorforelectronspectroscopy
AT chaset fullyintegratedmultichanneldetectorforelectronspectroscopy
AT evansd fullyintegratedmultichanneldetectorforelectronspectroscopy