Coriolis mass flow metering for three-phase flow: A case study

Previous work has described the use of Coriolis mass flow metering for two-phase (gas/liquid) flow. As the Coriolis meter provides both mass flow and density measurements, it is possible to resolve the mass flows of the gas and liquid in a two-phase mixture if their respective densities are known. T...

全面介紹

書目詳細資料
Main Authors: Henry, M, Tombs, M, Zamora, M, Zhou, F
格式: Journal article
語言:English
出版: 2013
_version_ 1826267829493563392
author Henry, M
Tombs, M
Zamora, M
Zhou, F
author_facet Henry, M
Tombs, M
Zamora, M
Zhou, F
author_sort Henry, M
collection OXFORD
description Previous work has described the use of Coriolis mass flow metering for two-phase (gas/liquid) flow. As the Coriolis meter provides both mass flow and density measurements, it is possible to resolve the mass flows of the gas and liquid in a two-phase mixture if their respective densities are known. To apply Coriolis metering to a three-phase (oil/water/gas) mixture, an additional measurement is required. In the work described in this paper, a water cut meter is used to indicate what proportion of the liquid flow is water. This provides sufficient information to calculate the mass flows of the water, oil and gas components. This paper is believed to be the first to detail an implementation of three-phase flow metering using Coriolis technology where phase separation is not applied. Trials have taken place at the UK National Flow Standards Laboratory three-phase facility, on a commercial three-phase meter based on the Coriolis meter/water cut measurement principle. For the 50. mm metering system, the total liquid flow rate ranged from 2.4. kg/s up to 11. kg/s, the water cut ranged from 0% to 100%, and the gas volume fraction (GVF) from 0 to 50%. In a formally observed trial, 75 test points were taken at a temperature of approximately 40. °C and with a skid inlet pressure of approximately 350. kPa. Over 95% of the test results fell within the desired specification, defined as follows: the total (oil+water) liquid mass flow error should fall within ±2.5%, and the gas mass flow error within ±5.0%. The oil mass flow error limit is ±6.0% for water cuts less than 70%, while for water cuts between 70% and 95% the oil mass flow error limit is ±15.0%. These results demonstrate the potential for using Coriolis mass flow metering combined with water cut metering for three-phase (oil/water/gas) measurement. © 2013 Elsevier Ltd.
first_indexed 2024-03-06T21:00:13Z
format Journal article
id oxford-uuid:3aa1f3cf-1e4f-4f14-8db9-3e5f0d416a9c
institution University of Oxford
language English
last_indexed 2024-03-06T21:00:13Z
publishDate 2013
record_format dspace
spelling oxford-uuid:3aa1f3cf-1e4f-4f14-8db9-3e5f0d416a9c2022-03-26T14:02:45ZCoriolis mass flow metering for three-phase flow: A case studyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:3aa1f3cf-1e4f-4f14-8db9-3e5f0d416a9cEnglishSymplectic Elements at Oxford2013Henry, MTombs, MZamora, MZhou, FPrevious work has described the use of Coriolis mass flow metering for two-phase (gas/liquid) flow. As the Coriolis meter provides both mass flow and density measurements, it is possible to resolve the mass flows of the gas and liquid in a two-phase mixture if their respective densities are known. To apply Coriolis metering to a three-phase (oil/water/gas) mixture, an additional measurement is required. In the work described in this paper, a water cut meter is used to indicate what proportion of the liquid flow is water. This provides sufficient information to calculate the mass flows of the water, oil and gas components. This paper is believed to be the first to detail an implementation of three-phase flow metering using Coriolis technology where phase separation is not applied. Trials have taken place at the UK National Flow Standards Laboratory three-phase facility, on a commercial three-phase meter based on the Coriolis meter/water cut measurement principle. For the 50. mm metering system, the total liquid flow rate ranged from 2.4. kg/s up to 11. kg/s, the water cut ranged from 0% to 100%, and the gas volume fraction (GVF) from 0 to 50%. In a formally observed trial, 75 test points were taken at a temperature of approximately 40. °C and with a skid inlet pressure of approximately 350. kPa. Over 95% of the test results fell within the desired specification, defined as follows: the total (oil+water) liquid mass flow error should fall within ±2.5%, and the gas mass flow error within ±5.0%. The oil mass flow error limit is ±6.0% for water cuts less than 70%, while for water cuts between 70% and 95% the oil mass flow error limit is ±15.0%. These results demonstrate the potential for using Coriolis mass flow metering combined with water cut metering for three-phase (oil/water/gas) measurement. © 2013 Elsevier Ltd.
spellingShingle Henry, M
Tombs, M
Zamora, M
Zhou, F
Coriolis mass flow metering for three-phase flow: A case study
title Coriolis mass flow metering for three-phase flow: A case study
title_full Coriolis mass flow metering for three-phase flow: A case study
title_fullStr Coriolis mass flow metering for three-phase flow: A case study
title_full_unstemmed Coriolis mass flow metering for three-phase flow: A case study
title_short Coriolis mass flow metering for three-phase flow: A case study
title_sort coriolis mass flow metering for three phase flow a case study
work_keys_str_mv AT henrym coriolismassflowmeteringforthreephaseflowacasestudy
AT tombsm coriolismassflowmeteringforthreephaseflowacasestudy
AT zamoram coriolismassflowmeteringforthreephaseflowacasestudy
AT zhouf coriolismassflowmeteringforthreephaseflowacasestudy