Laser studies of plasmas

<p>Measurement of the intrinsic properties of processing plasmas is critically important in understanding discharges so that the optimum conditions can be achieved. Several different diagnostic methods have been developed and tested.</p><p>A planar probe has been used to measure t...

पूर्ण विवरण

ग्रंथसूची विवरण
मुख्य लेखकों: Jacobs, R, Jacobs, Robert
अन्य लेखक: Hancock, G
स्वरूप: थीसिस
भाषा:English
प्रकाशित: 2000
विषय:
_version_ 1826316399497183232
author Jacobs, R
Jacobs, Robert
author2 Hancock, G
author_facet Hancock, G
Jacobs, R
Jacobs, Robert
author_sort Jacobs, R
collection OXFORD
description <p>Measurement of the intrinsic properties of processing plasmas is critically important in understanding discharges so that the optimum conditions can be achieved. Several different diagnostic methods have been developed and tested.</p><p>A planar probe has been used to measure the ion flux and electron temperature in both inductively coupled and capacitively coupled plasma systems, at various pressures and applied powers, using the assumption that the electron energy distribution is a Maxwellian.</p> Frequency modulation spectroscopy (FMS) has been used to detect species in a plasma. It has been shown to be very effective, giving a significantly increased S/N ratio compared to both single pass absorption and low frequency mechanical modulation techniques. It has been used to measure excited argon atom concentrations, in both capacitively and inductively produced plasmas. The argon atom 4s[3/2]<sub>1</sub> level concentration was found to be between 2 x 10<sup>8</sup> and 1 x 10<sup>11</sup> atom/cm<sup>3</sup> and to generally increase with increasing applied power and to decrease with increasing total pressure. The temperature of the atoms was also measured and was found to be approximately 323 ± 17 K.<p>A simple compact laser source at 308 nm has been produced from a frequency doubled cooled commercial diode laser. This has been used to detect the OH radical, by absorption, within the afterglow of a microwave discharge, produced either directly or chemically. Simple kinetic models have provided explanations of the variations in OH concentration with discharge conditions. A novel method, cavity laser induced fluorescence (CLIP), that combines the advantages of both laser induced fluorescence (LIF) and cavity ring down spectroscopy CRDS, has been shown to increase the sensitivity of a diagnostic system compared to absorption. This method could be used to follow concentration variations of a reaction in a single laser shot. Although such variation can be observed using LIF, it requires a calibration and a many laser shot experiment with a signal recorded at each time point. Whilst CRDS allows temporal information about the absolute concentrations of the species observed to be obtained, it is not as sensitive as LIF. By combining the two in CLIP, it may be possible to retain the sensitivity of LIF with the advantage of CRDS so that absolute and time varying concentrations can be obtained in a single pulsed laser shot.</p><p>LIF and CRDS signals have been observed using the A <sup>2</sup>?<sub>u</sub> ? X <sup>2</sup>S<sub>g</sub><sup>+</sup> transition of the N<sub>2</sub><sup>+</sup> ion. The lifetime of the A <sup>2</sup>?<sub>u</sub> state in the discharge was found to be sufficiently long for a time of flight experiment to be contemplated (an ion with a velocity of 10 kms<sup>-1</sup> on average would travel 5 mm before radiating). Although the preliminary tests for the time of flight experiment have shown that this method is not feasible with a pulsed laser, the basic cavity locking procedures required for an analogous continuous wave experiment have been successfully demonstrated.</p><p>A frequency doubled diode laser source has been constructed and tested, with the eventual aim of detecting N<sub>2</sub><sup>+</sup> via the B <sup>2</sup>S<sub>u</sub> ? X <sup>2</sup>S<sub>g</sub><sup>+</sup> electronic transition. This has been found to be insufficiently intense to be used for a proposed two dimensional velocity mapping experiment, but several strategies to improve its performance are suggested.</p>
first_indexed 2024-03-06T21:10:12Z
format Thesis
id oxford-uuid:3de1c919-d7ce-485c-94c8-e5ab9e8e4a4b
institution University of Oxford
language English
last_indexed 2024-12-09T03:44:27Z
publishDate 2000
record_format dspace
spelling oxford-uuid:3de1c919-d7ce-485c-94c8-e5ab9e8e4a4b2024-12-07T15:55:30ZLaser studies of plasmasThesishttp://purl.org/coar/resource_type/c_db06uuid:3de1c919-d7ce-485c-94c8-e5ab9e8e4a4bModulation spectroscopyFluorescence spectroscopyEnglishPolonsky Theses Digitisation Project2000Jacobs, RJacobs, RobertHancock, GHancock, G<p>Measurement of the intrinsic properties of processing plasmas is critically important in understanding discharges so that the optimum conditions can be achieved. Several different diagnostic methods have been developed and tested.</p><p>A planar probe has been used to measure the ion flux and electron temperature in both inductively coupled and capacitively coupled plasma systems, at various pressures and applied powers, using the assumption that the electron energy distribution is a Maxwellian.</p> Frequency modulation spectroscopy (FMS) has been used to detect species in a plasma. It has been shown to be very effective, giving a significantly increased S/N ratio compared to both single pass absorption and low frequency mechanical modulation techniques. It has been used to measure excited argon atom concentrations, in both capacitively and inductively produced plasmas. The argon atom 4s[3/2]<sub>1</sub> level concentration was found to be between 2 x 10<sup>8</sup> and 1 x 10<sup>11</sup> atom/cm<sup>3</sup> and to generally increase with increasing applied power and to decrease with increasing total pressure. The temperature of the atoms was also measured and was found to be approximately 323 ± 17 K.<p>A simple compact laser source at 308 nm has been produced from a frequency doubled cooled commercial diode laser. This has been used to detect the OH radical, by absorption, within the afterglow of a microwave discharge, produced either directly or chemically. Simple kinetic models have provided explanations of the variations in OH concentration with discharge conditions. A novel method, cavity laser induced fluorescence (CLIP), that combines the advantages of both laser induced fluorescence (LIF) and cavity ring down spectroscopy CRDS, has been shown to increase the sensitivity of a diagnostic system compared to absorption. This method could be used to follow concentration variations of a reaction in a single laser shot. Although such variation can be observed using LIF, it requires a calibration and a many laser shot experiment with a signal recorded at each time point. Whilst CRDS allows temporal information about the absolute concentrations of the species observed to be obtained, it is not as sensitive as LIF. By combining the two in CLIP, it may be possible to retain the sensitivity of LIF with the advantage of CRDS so that absolute and time varying concentrations can be obtained in a single pulsed laser shot.</p><p>LIF and CRDS signals have been observed using the A <sup>2</sup>?<sub>u</sub> ? X <sup>2</sup>S<sub>g</sub><sup>+</sup> transition of the N<sub>2</sub><sup>+</sup> ion. The lifetime of the A <sup>2</sup>?<sub>u</sub> state in the discharge was found to be sufficiently long for a time of flight experiment to be contemplated (an ion with a velocity of 10 kms<sup>-1</sup> on average would travel 5 mm before radiating). Although the preliminary tests for the time of flight experiment have shown that this method is not feasible with a pulsed laser, the basic cavity locking procedures required for an analogous continuous wave experiment have been successfully demonstrated.</p><p>A frequency doubled diode laser source has been constructed and tested, with the eventual aim of detecting N<sub>2</sub><sup>+</sup> via the B <sup>2</sup>S<sub>u</sub> ? X <sup>2</sup>S<sub>g</sub><sup>+</sup> electronic transition. This has been found to be insufficiently intense to be used for a proposed two dimensional velocity mapping experiment, but several strategies to improve its performance are suggested.</p>
spellingShingle Modulation spectroscopy
Fluorescence spectroscopy
Jacobs, R
Jacobs, Robert
Laser studies of plasmas
title Laser studies of plasmas
title_full Laser studies of plasmas
title_fullStr Laser studies of plasmas
title_full_unstemmed Laser studies of plasmas
title_short Laser studies of plasmas
title_sort laser studies of plasmas
topic Modulation spectroscopy
Fluorescence spectroscopy
work_keys_str_mv AT jacobsr laserstudiesofplasmas
AT jacobsrobert laserstudiesofplasmas