A comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions.
BACKGROUND: Breast-feeding in the postpartum period is known to induce intense uterine contractions with pain in the lower abdomen. AIMS: The primary aim of this study was to compare the effects of high and low intensity, high frequency Transcutaneous Electric Nerve Stimulation (TENS) on pain and d...
Hoofdauteurs: | , , , , |
---|---|
Formaat: | Journal article |
Taal: | English |
Gepubliceerd in: |
2007
|
_version_ | 1826268544611909632 |
---|---|
author | Olsén, M Elden, H Janson, E Lilja, H Stener-Victorin, E |
author_facet | Olsén, M Elden, H Janson, E Lilja, H Stener-Victorin, E |
author_sort | Olsén, M |
collection | OXFORD |
description | BACKGROUND: Breast-feeding in the postpartum period is known to induce intense uterine contractions with pain in the lower abdomen. AIMS: The primary aim of this study was to compare the effects of high and low intensity, high frequency Transcutaneous Electric Nerve Stimulation (TENS) on pain and discomfort of postpartum uterine contractions. The secondary aim was to evaluate discomfort experienced from the stimulation itself. METHODS: Twenty-one newly delivered women participated in this single-blind trial, 12 women received high intensity, high-frequency TENS (HI TENS) and 9 women received low intensity, high-frequency TENS (LI TENS). The electrodes were placed abdominally on each side of the uterus. Stimulation was done during one minute. Visual analogue scales were used to evaluate the intensity of the pain before and after stimulation. A verbal scale was used to estimate sensation of discomfort before, during and after stimulation. RESULTS: The median decrease in pain ratings before and after treatment by VAS was larger in the HI TENS group -49 mm (95% CI -66.5--33.2) than in the LI TENS group -21 mm (95% CI -39.0--20.0). The reduction of pain was most pronounced in the HI TENS group (median difference 28 (95% CI was 14.0-53.0). Furthermore, the HI TENS group experienced significantly less discomfort of the uterine contractions after stimulation (p<0.01) but they also experienced more discomfort of the stimulation than women in the LI TENS group (p<0.01). CONCLUSION: The women treated with HI TENS, experienced significantly less postpartum pain and discomfort to those treated with LI TENS even though the discomfort from the stimulation with HI TENS was greater. |
first_indexed | 2024-03-06T21:11:19Z |
format | Journal article |
id | oxford-uuid:3e44e89c-68c6-40dc-82b2-e84638eb3d72 |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-06T21:11:19Z |
publishDate | 2007 |
record_format | dspace |
spelling | oxford-uuid:3e44e89c-68c6-40dc-82b2-e84638eb3d722022-03-26T14:24:34ZA comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:3e44e89c-68c6-40dc-82b2-e84638eb3d72EnglishSymplectic Elements at Oxford2007Olsén, MElden, HJanson, ELilja, HStener-Victorin, E BACKGROUND: Breast-feeding in the postpartum period is known to induce intense uterine contractions with pain in the lower abdomen. AIMS: The primary aim of this study was to compare the effects of high and low intensity, high frequency Transcutaneous Electric Nerve Stimulation (TENS) on pain and discomfort of postpartum uterine contractions. The secondary aim was to evaluate discomfort experienced from the stimulation itself. METHODS: Twenty-one newly delivered women participated in this single-blind trial, 12 women received high intensity, high-frequency TENS (HI TENS) and 9 women received low intensity, high-frequency TENS (LI TENS). The electrodes were placed abdominally on each side of the uterus. Stimulation was done during one minute. Visual analogue scales were used to evaluate the intensity of the pain before and after stimulation. A verbal scale was used to estimate sensation of discomfort before, during and after stimulation. RESULTS: The median decrease in pain ratings before and after treatment by VAS was larger in the HI TENS group -49 mm (95% CI -66.5--33.2) than in the LI TENS group -21 mm (95% CI -39.0--20.0). The reduction of pain was most pronounced in the HI TENS group (median difference 28 (95% CI was 14.0-53.0). Furthermore, the HI TENS group experienced significantly less discomfort of the uterine contractions after stimulation (p<0.01) but they also experienced more discomfort of the stimulation than women in the LI TENS group (p<0.01). CONCLUSION: The women treated with HI TENS, experienced significantly less postpartum pain and discomfort to those treated with LI TENS even though the discomfort from the stimulation with HI TENS was greater. |
spellingShingle | Olsén, M Elden, H Janson, E Lilja, H Stener-Victorin, E A comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions. |
title | A comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions. |
title_full | A comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions. |
title_fullStr | A comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions. |
title_full_unstemmed | A comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions. |
title_short | A comparison of high- versus low-intensity, high-frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions. |
title_sort | comparison of high versus low intensity high frequency transcutaneous electric nerve stimulation for painful postpartum uterine contractions |
work_keys_str_mv | AT olsenm acomparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT eldenh acomparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT jansone acomparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT liljah acomparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT stenervictorine acomparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT olsenm comparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT eldenh comparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT jansone comparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT liljah comparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions AT stenervictorine comparisonofhighversuslowintensityhighfrequencytranscutaneouselectricnervestimulationforpainfulpostpartumuterinecontractions |