A comparison of indirect methods for continuous estimation of arterial PCO2 in men.
Four different measures (PETCO2, PACO2, PADCO2, and PJCO2) for indirectly estimating arterial PCO2 (PaCO2) from respired gas at the mouth have been investigated. PETCO2 was the end-tidal PCO2. PACO2 was calculated using a reconstruction of the alveolar oscillation of PCO2 obtained from the end-tidal...
Main Authors: | , , , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
1990
|
_version_ | 1797065623968153600 |
---|---|
author | Robbins, P Conway, J Cunningham, D Khamnei, S Paterson, D |
author_facet | Robbins, P Conway, J Cunningham, D Khamnei, S Paterson, D |
author_sort | Robbins, P |
collection | OXFORD |
description | Four different measures (PETCO2, PACO2, PADCO2, and PJCO2) for indirectly estimating arterial PCO2 (PaCO2) from respired gas at the mouth have been investigated. PETCO2 was the end-tidal PCO2. PACO2 was calculated using a reconstruction of the alveolar oscillation of PCO2 obtained from the end-tidal "plateau" in PCO2. PADCO2 was calculated as for PACO2 except that the effects of dead space were incorporated. PJCO2 was calculated from an empirical relationship involving PETCO2 and tidal volume. Six subjects were studied at rest and during cycle ergometry at 50 and 100 W while breathing a variety of gas mixtures. Arterial samples were drawn for determination of true PaCO2. The differences for each method between estimated and true PaCO2 at rest and at 50 and 100 W were as follows: PETCO2, -1.35 +/- 2.64, 1.67 +/- 2.31, and 2.67 +/- 2.02 (SD) Torr; PaCO2, -2.15 +/- 2.73, -0.80 +/- 2.18, and -0.35 +/- 2.31 (SD) Torr; PADCO2, -1.55 +/- 2.54, 0.25 +/- 2.16, and 0.63 +/- 2.26 (SD) Torr; and PJCO2, -1.41 +/- 2.30, 0.12 +/- 1.79, and 0.08 +/- 1.96 (SD) Torr. It is concluded that, at rest, all methods significantly underestimate true PaCO2 and during exercise PETCO2 significantly overestimates PaCO2, but no bias was detected for any of the other methods. |
first_indexed | 2024-03-06T21:31:17Z |
format | Journal article |
id | oxford-uuid:44c2496a-2598-4dca-938e-02ec0a851e0a |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-06T21:31:17Z |
publishDate | 1990 |
record_format | dspace |
spelling | oxford-uuid:44c2496a-2598-4dca-938e-02ec0a851e0a2022-03-26T15:03:38ZA comparison of indirect methods for continuous estimation of arterial PCO2 in men.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:44c2496a-2598-4dca-938e-02ec0a851e0aEnglishSymplectic Elements at Oxford1990Robbins, PConway, JCunningham, DKhamnei, SPaterson, DFour different measures (PETCO2, PACO2, PADCO2, and PJCO2) for indirectly estimating arterial PCO2 (PaCO2) from respired gas at the mouth have been investigated. PETCO2 was the end-tidal PCO2. PACO2 was calculated using a reconstruction of the alveolar oscillation of PCO2 obtained from the end-tidal "plateau" in PCO2. PADCO2 was calculated as for PACO2 except that the effects of dead space were incorporated. PJCO2 was calculated from an empirical relationship involving PETCO2 and tidal volume. Six subjects were studied at rest and during cycle ergometry at 50 and 100 W while breathing a variety of gas mixtures. Arterial samples were drawn for determination of true PaCO2. The differences for each method between estimated and true PaCO2 at rest and at 50 and 100 W were as follows: PETCO2, -1.35 +/- 2.64, 1.67 +/- 2.31, and 2.67 +/- 2.02 (SD) Torr; PaCO2, -2.15 +/- 2.73, -0.80 +/- 2.18, and -0.35 +/- 2.31 (SD) Torr; PADCO2, -1.55 +/- 2.54, 0.25 +/- 2.16, and 0.63 +/- 2.26 (SD) Torr; and PJCO2, -1.41 +/- 2.30, 0.12 +/- 1.79, and 0.08 +/- 1.96 (SD) Torr. It is concluded that, at rest, all methods significantly underestimate true PaCO2 and during exercise PETCO2 significantly overestimates PaCO2, but no bias was detected for any of the other methods. |
spellingShingle | Robbins, P Conway, J Cunningham, D Khamnei, S Paterson, D A comparison of indirect methods for continuous estimation of arterial PCO2 in men. |
title | A comparison of indirect methods for continuous estimation of arterial PCO2 in men. |
title_full | A comparison of indirect methods for continuous estimation of arterial PCO2 in men. |
title_fullStr | A comparison of indirect methods for continuous estimation of arterial PCO2 in men. |
title_full_unstemmed | A comparison of indirect methods for continuous estimation of arterial PCO2 in men. |
title_short | A comparison of indirect methods for continuous estimation of arterial PCO2 in men. |
title_sort | comparison of indirect methods for continuous estimation of arterial pco2 in men |
work_keys_str_mv | AT robbinsp acomparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT conwayj acomparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT cunninghamd acomparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT khamneis acomparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT patersond acomparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT robbinsp comparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT conwayj comparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT cunninghamd comparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT khamneis comparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen AT patersond comparisonofindirectmethodsforcontinuousestimationofarterialpco2inmen |