Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography

<strong>AIM: </strong>To describe and evaluate a standardized protocol for measuring the choroidal thickness (ChT) using enhanced depth imaging optical coherence tomography (EDI OCT). <br><strong> METHODS: </strong>Single 9 mm EDI OCT line scans across the fovea were us...

Full description

Bibliographic Details
Main Authors: Boonarpha, N, Zheng, Y, Stangos, AN, Lu, H, Raj, A, Czanner, G, Harding, SP, Nair-Sahni, J
Format: Journal article
Language:English
Published: IJO Press 2015
_version_ 1797107469028163584
author Boonarpha, N
Zheng, Y
Stangos, AN
Lu, H
Raj, A
Czanner, G
Harding, SP
Nair-Sahni, J
author_facet Boonarpha, N
Zheng, Y
Stangos, AN
Lu, H
Raj, A
Czanner, G
Harding, SP
Nair-Sahni, J
author_sort Boonarpha, N
collection OXFORD
description <strong>AIM: </strong>To describe and evaluate a standardized protocol for measuring the choroidal thickness (ChT) using enhanced depth imaging optical coherence tomography (EDI OCT). <br><strong> METHODS: </strong>Single 9 mm EDI OCT line scans across the fovea were used for this study. The protocol used in this study classified the EDI OCT images into four groups based on the appearance of the choroidal-scleral interface and suprachoroidal space. Two evaluation iterations of experiments were performed:first, the protocol was validated in a pilot study of 12 healthy eyes. Afterwards, the applicability of the protocol was tested in 82 eyes of patients with diabetes. Inter-observer and intra-observer agreements on image classifications were performed using Cohen’s kappa coefficient (k). Intraclass correlation coefficient (ICC) and Bland-Altman’s methodology were used for the measurement of the ChT. <br><strong> RESULTS: </strong>There was a moderate (k=0.42) and perfect (k=1) inter- and intra-observer agreements on image classifications from healthy eyes images and substantial (k=0.66) and almost perfect (k=0.86) agreements from diabetic eyes images. The proposed protocol showed excellent inter- and intra-observer agreements for the ChT measurements on both, healthy eyes and diabetic eyes (ICC>0.90 in all image categories). The Bland-Altman plot showed a relatively large ChT measurement agreement in the scans that contained less visible choroidal outer boundary. <br><strong> CONCLUSIONS: </strong>A protocol to standardize ChT measurements in EDI OCT images has been developed; the results obtained using this protocol show that the technique is accurate and reliable for routine clinical practice and research.
first_indexed 2024-03-07T07:16:35Z
format Journal article
id oxford-uuid:45c403e9-048b-473c-82c9-393ed85d2e06
institution University of Oxford
language English
last_indexed 2024-03-07T07:16:35Z
publishDate 2015
publisher IJO Press
record_format dspace
spelling oxford-uuid:45c403e9-048b-473c-82c9-393ed85d2e062022-08-19T16:12:46ZStandardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomographyJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:45c403e9-048b-473c-82c9-393ed85d2e06EnglishSymplectic ElementsIJO Press2015Boonarpha, NZheng, YStangos, ANLu, HRaj, ACzanner, GHarding, SPNair-Sahni, J<strong>AIM: </strong>To describe and evaluate a standardized protocol for measuring the choroidal thickness (ChT) using enhanced depth imaging optical coherence tomography (EDI OCT). <br><strong> METHODS: </strong>Single 9 mm EDI OCT line scans across the fovea were used for this study. The protocol used in this study classified the EDI OCT images into four groups based on the appearance of the choroidal-scleral interface and suprachoroidal space. Two evaluation iterations of experiments were performed:first, the protocol was validated in a pilot study of 12 healthy eyes. Afterwards, the applicability of the protocol was tested in 82 eyes of patients with diabetes. Inter-observer and intra-observer agreements on image classifications were performed using Cohen’s kappa coefficient (k). Intraclass correlation coefficient (ICC) and Bland-Altman’s methodology were used for the measurement of the ChT. <br><strong> RESULTS: </strong>There was a moderate (k=0.42) and perfect (k=1) inter- and intra-observer agreements on image classifications from healthy eyes images and substantial (k=0.66) and almost perfect (k=0.86) agreements from diabetic eyes images. The proposed protocol showed excellent inter- and intra-observer agreements for the ChT measurements on both, healthy eyes and diabetic eyes (ICC>0.90 in all image categories). The Bland-Altman plot showed a relatively large ChT measurement agreement in the scans that contained less visible choroidal outer boundary. <br><strong> CONCLUSIONS: </strong>A protocol to standardize ChT measurements in EDI OCT images has been developed; the results obtained using this protocol show that the technique is accurate and reliable for routine clinical practice and research.
spellingShingle Boonarpha, N
Zheng, Y
Stangos, AN
Lu, H
Raj, A
Czanner, G
Harding, SP
Nair-Sahni, J
Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
title Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
title_full Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
title_fullStr Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
title_full_unstemmed Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
title_short Standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
title_sort standardization of choroidal thickness measurements using enhanced depth imaging optical coherence tomography
work_keys_str_mv AT boonarphan standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography
AT zhengy standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography
AT stangosan standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography
AT luh standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography
AT raja standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography
AT czannerg standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography
AT hardingsp standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography
AT nairsahnij standardizationofchoroidalthicknessmeasurementsusingenhanceddepthimagingopticalcoherencetomography