Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan
Power Doppler ultrasound imaging provides a non-invasive method to explore tissue vascularity in real-time. It has farreaching clinical utility, for example to assess the perfusion of organs such as the placenta. In this study, a fully automated method was proposed to standardize the power Doppler s...
Main Authors: | , , |
---|---|
Format: | Conference item |
Language: | English |
Published: |
Society of Photo-optical Instrumentation Engineers
2020
|
_version_ | 1797067624688910336 |
---|---|
author | Yin, Y Looney, P Collins, SL |
author_facet | Yin, Y Looney, P Collins, SL |
author_sort | Yin, Y |
collection | OXFORD |
description | Power Doppler ultrasound imaging provides a non-invasive method to explore tissue vascularity in real-time. It has farreaching clinical utility, for example to assess the perfusion of organs such as the placenta. In this study, a fully automated method was proposed to standardize the power Doppler signals in the placental bed to estimate the perfusion by a technique known as fractional moving blood volume (FMBV). The uterine vasculature was extracted by a region growing algorithm from 3D power Doppler scan and further localized based on the placenta segmentation obtained by a multi-class fully Convolution Neural Network (CNN). The largest vessel close to the volume of interest (VOI) in placenta was identified within which the average power Doppler signal was used as a standardization value to correct the signal attenuation in placenta bed to estimate the FMBV measurement. This is the first successful attempt to automatically identify individual blood vessel segments from a complex uterine vascular plexus. The proposed method was performed in twenty 3D power Doppler scans of first trimester placenta with promising results. The mean ± STD FMBV value was 21.35% ± 9.43%. With further analysis and evaluation in large dataset, the proposed method will serve as an efficient tool for assessing the blood perfusion in placenta bed. |
first_indexed | 2024-03-06T21:59:01Z |
format | Conference item |
id | oxford-uuid:4df4939c-f401-42c8-b0c8-1fb6c56e2fa0 |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-06T21:59:01Z |
publishDate | 2020 |
publisher | Society of Photo-optical Instrumentation Engineers |
record_format | dspace |
spelling | oxford-uuid:4df4939c-f401-42c8-b0c8-1fb6c56e2fa02022-03-26T15:58:25ZStandardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scanConference itemhttp://purl.org/coar/resource_type/c_5794uuid:4df4939c-f401-42c8-b0c8-1fb6c56e2fa0EnglishSymplectic ElementsSociety of Photo-optical Instrumentation Engineers2020Yin, YLooney, PCollins, SLPower Doppler ultrasound imaging provides a non-invasive method to explore tissue vascularity in real-time. It has farreaching clinical utility, for example to assess the perfusion of organs such as the placenta. In this study, a fully automated method was proposed to standardize the power Doppler signals in the placental bed to estimate the perfusion by a technique known as fractional moving blood volume (FMBV). The uterine vasculature was extracted by a region growing algorithm from 3D power Doppler scan and further localized based on the placenta segmentation obtained by a multi-class fully Convolution Neural Network (CNN). The largest vessel close to the volume of interest (VOI) in placenta was identified within which the average power Doppler signal was used as a standardization value to correct the signal attenuation in placenta bed to estimate the FMBV measurement. This is the first successful attempt to automatically identify individual blood vessel segments from a complex uterine vascular plexus. The proposed method was performed in twenty 3D power Doppler scans of first trimester placenta with promising results. The mean ± STD FMBV value was 21.35% ± 9.43%. With further analysis and evaluation in large dataset, the proposed method will serve as an efficient tool for assessing the blood perfusion in placenta bed. |
spellingShingle | Yin, Y Looney, P Collins, SL Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan |
title | Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan |
title_full | Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan |
title_fullStr | Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan |
title_full_unstemmed | Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan |
title_short | Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan |
title_sort | standardization of blood flow measurements by automated vascular analysis from power doppler ultrasound scan |
work_keys_str_mv | AT yiny standardizationofbloodflowmeasurementsbyautomatedvascularanalysisfrompowerdopplerultrasoundscan AT looneyp standardizationofbloodflowmeasurementsbyautomatedvascularanalysisfrompowerdopplerultrasoundscan AT collinssl standardizationofbloodflowmeasurementsbyautomatedvascularanalysisfrompowerdopplerultrasoundscan |