Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan

Power Doppler ultrasound imaging provides a non-invasive method to explore tissue vascularity in real-time. It has farreaching clinical utility, for example to assess the perfusion of organs such as the placenta. In this study, a fully automated method was proposed to standardize the power Doppler s...

Full description

Bibliographic Details
Main Authors: Yin, Y, Looney, P, Collins, SL
Format: Conference item
Language:English
Published: Society of Photo-optical Instrumentation Engineers 2020
_version_ 1797067624688910336
author Yin, Y
Looney, P
Collins, SL
author_facet Yin, Y
Looney, P
Collins, SL
author_sort Yin, Y
collection OXFORD
description Power Doppler ultrasound imaging provides a non-invasive method to explore tissue vascularity in real-time. It has farreaching clinical utility, for example to assess the perfusion of organs such as the placenta. In this study, a fully automated method was proposed to standardize the power Doppler signals in the placental bed to estimate the perfusion by a technique known as fractional moving blood volume (FMBV). The uterine vasculature was extracted by a region growing algorithm from 3D power Doppler scan and further localized based on the placenta segmentation obtained by a multi-class fully Convolution Neural Network (CNN). The largest vessel close to the volume of interest (VOI) in placenta was identified within which the average power Doppler signal was used as a standardization value to correct the signal attenuation in placenta bed to estimate the FMBV measurement. This is the first successful attempt to automatically identify individual blood vessel segments from a complex uterine vascular plexus. The proposed method was performed in twenty 3D power Doppler scans of first trimester placenta with promising results. The mean ± STD FMBV value was 21.35% ± 9.43%. With further analysis and evaluation in large dataset, the proposed method will serve as an efficient tool for assessing the blood perfusion in placenta bed.
first_indexed 2024-03-06T21:59:01Z
format Conference item
id oxford-uuid:4df4939c-f401-42c8-b0c8-1fb6c56e2fa0
institution University of Oxford
language English
last_indexed 2024-03-06T21:59:01Z
publishDate 2020
publisher Society of Photo-optical Instrumentation Engineers
record_format dspace
spelling oxford-uuid:4df4939c-f401-42c8-b0c8-1fb6c56e2fa02022-03-26T15:58:25ZStandardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scanConference itemhttp://purl.org/coar/resource_type/c_5794uuid:4df4939c-f401-42c8-b0c8-1fb6c56e2fa0EnglishSymplectic ElementsSociety of Photo-optical Instrumentation Engineers2020Yin, YLooney, PCollins, SLPower Doppler ultrasound imaging provides a non-invasive method to explore tissue vascularity in real-time. It has farreaching clinical utility, for example to assess the perfusion of organs such as the placenta. In this study, a fully automated method was proposed to standardize the power Doppler signals in the placental bed to estimate the perfusion by a technique known as fractional moving blood volume (FMBV). The uterine vasculature was extracted by a region growing algorithm from 3D power Doppler scan and further localized based on the placenta segmentation obtained by a multi-class fully Convolution Neural Network (CNN). The largest vessel close to the volume of interest (VOI) in placenta was identified within which the average power Doppler signal was used as a standardization value to correct the signal attenuation in placenta bed to estimate the FMBV measurement. This is the first successful attempt to automatically identify individual blood vessel segments from a complex uterine vascular plexus. The proposed method was performed in twenty 3D power Doppler scans of first trimester placenta with promising results. The mean ± STD FMBV value was 21.35% ± 9.43%. With further analysis and evaluation in large dataset, the proposed method will serve as an efficient tool for assessing the blood perfusion in placenta bed.
spellingShingle Yin, Y
Looney, P
Collins, SL
Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan
title Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan
title_full Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan
title_fullStr Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan
title_full_unstemmed Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan
title_short Standardization of blood flow measurements by automated vascular analysis from power Doppler ultrasound scan
title_sort standardization of blood flow measurements by automated vascular analysis from power doppler ultrasound scan
work_keys_str_mv AT yiny standardizationofbloodflowmeasurementsbyautomatedvascularanalysisfrompowerdopplerultrasoundscan
AT looneyp standardizationofbloodflowmeasurementsbyautomatedvascularanalysisfrompowerdopplerultrasoundscan
AT collinssl standardizationofbloodflowmeasurementsbyautomatedvascularanalysisfrompowerdopplerultrasoundscan