The effects of pupil dilation on MAIA microperimetry

<h4>Background</h4> <p>MAIA microperimetry assesses macular sensitivity to projected point light sources and maps eye movements to assess fixation stability. While microperimetry is gaining prominence as an assessment tool in clinical and research settings, there is no consensus o...

Full description

Bibliographic Details
Main Authors: Jolly, J, Han, R, Xue, K, MacLaren, R
Format: Journal article
Published: Wiley 2017
_version_ 1797068720404692992
author Jolly, J
Han, R
Xue, K
MacLaren, R
author_facet Jolly, J
Han, R
Xue, K
MacLaren, R
author_sort Jolly, J
collection OXFORD
description <h4>Background</h4> <p>MAIA microperimetry assesses macular sensitivity to projected point light sources and maps eye movements to assess fixation stability. While microperimetry is gaining prominence as an assessment tool in clinical and research settings, there is no consensus on whether it should be performed before or after pupil dilation. No studies to date have examined the effect of pupil dilation on results. The aim of this project was to elucidate the effect of pupil dilation on microperimetry outcomes.</p> <h4>Design</h4> <p>Prospective audit.</p> <h4>Participants</h4> <p>Twenty healthy patients from post-operative cataract clinic and ten patients with choroideremia to simulate a disease with peripheral visual field loss.</p> <h4>Methods</h4> <p>Subjects underwent 10-2 68 point field testing using the MAIA microperimeter on each eye. Subjects then underwentrandomised dilation of one eye and the test was repeated in both eyes.</p> <h4>Main Outcome Measure</h4> <p>We compared changes in threshold sensitivity and fixation stability pre- and post-pupil dilation. The undilated eye was analysed for any learning or fatigue effect caused by test repetition.</p> <h4>Results</h4> <p>Dilation produced no significant effect on threshold sensitivity (dilation effect: -0.29 decibels (dB), p=0.23) or fixation stability in healthy controls or in choroideremia patients (dilation effect: +0.08log bivariate contour ellipse area (BCEA) p = 0.14). There was also no significant learning effect seen in the undilated eye, with no improvement in threshold sensitivity (order of eye testing: +0.03logBCEA, p=0.71).</p> <h4>Conclusions</h4> <p>In the clinical setting patients may be tested for 10 degree microperimetry with or without pupil dilation, as both scenarios yield consistent and interchangeable results.</p>
first_indexed 2024-03-06T22:14:14Z
format Journal article
id oxford-uuid:52db2d71-6590-49ed-b46e-ebfe1e4487f7
institution University of Oxford
last_indexed 2024-03-06T22:14:14Z
publishDate 2017
publisher Wiley
record_format dspace
spelling oxford-uuid:52db2d71-6590-49ed-b46e-ebfe1e4487f72022-03-26T16:28:00ZThe effects of pupil dilation on MAIA microperimetryJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:52db2d71-6590-49ed-b46e-ebfe1e4487f7Symplectic Elements at OxfordWiley2017Jolly, JHan, RXue, KMacLaren, R <h4>Background</h4> <p>MAIA microperimetry assesses macular sensitivity to projected point light sources and maps eye movements to assess fixation stability. While microperimetry is gaining prominence as an assessment tool in clinical and research settings, there is no consensus on whether it should be performed before or after pupil dilation. No studies to date have examined the effect of pupil dilation on results. The aim of this project was to elucidate the effect of pupil dilation on microperimetry outcomes.</p> <h4>Design</h4> <p>Prospective audit.</p> <h4>Participants</h4> <p>Twenty healthy patients from post-operative cataract clinic and ten patients with choroideremia to simulate a disease with peripheral visual field loss.</p> <h4>Methods</h4> <p>Subjects underwent 10-2 68 point field testing using the MAIA microperimeter on each eye. Subjects then underwentrandomised dilation of one eye and the test was repeated in both eyes.</p> <h4>Main Outcome Measure</h4> <p>We compared changes in threshold sensitivity and fixation stability pre- and post-pupil dilation. The undilated eye was analysed for any learning or fatigue effect caused by test repetition.</p> <h4>Results</h4> <p>Dilation produced no significant effect on threshold sensitivity (dilation effect: -0.29 decibels (dB), p=0.23) or fixation stability in healthy controls or in choroideremia patients (dilation effect: +0.08log bivariate contour ellipse area (BCEA) p = 0.14). There was also no significant learning effect seen in the undilated eye, with no improvement in threshold sensitivity (order of eye testing: +0.03logBCEA, p=0.71).</p> <h4>Conclusions</h4> <p>In the clinical setting patients may be tested for 10 degree microperimetry with or without pupil dilation, as both scenarios yield consistent and interchangeable results.</p>
spellingShingle Jolly, J
Han, R
Xue, K
MacLaren, R
The effects of pupil dilation on MAIA microperimetry
title The effects of pupil dilation on MAIA microperimetry
title_full The effects of pupil dilation on MAIA microperimetry
title_fullStr The effects of pupil dilation on MAIA microperimetry
title_full_unstemmed The effects of pupil dilation on MAIA microperimetry
title_short The effects of pupil dilation on MAIA microperimetry
title_sort effects of pupil dilation on maia microperimetry
work_keys_str_mv AT jollyj theeffectsofpupildilationonmaiamicroperimetry
AT hanr theeffectsofpupildilationonmaiamicroperimetry
AT xuek theeffectsofpupildilationonmaiamicroperimetry
AT maclarenr theeffectsofpupildilationonmaiamicroperimetry
AT jollyj effectsofpupildilationonmaiamicroperimetry
AT hanr effectsofpupildilationonmaiamicroperimetry
AT xuek effectsofpupildilationonmaiamicroperimetry
AT maclarenr effectsofpupildilationonmaiamicroperimetry