Multi-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal Subjects

Clinical studies on atherosclerosis agree that multi-contrast MRI is the most promising technique for in-vivo characterization of carotid plaques. Multi-contrast image registration is essential for this application, because it corrects misalignments caused by patient motion during MRI acquisition. T...

Full description

Bibliographic Details
Main Authors: Biasiolli, L, Noble, A, Robson, M
Format: Conference item
Published: 2010
_version_ 1797068791874584576
author Biasiolli, L
Noble, A
Robson, M
author_facet Biasiolli, L
Noble, A
Robson, M
author_sort Biasiolli, L
collection OXFORD
description Clinical studies on atherosclerosis agree that multi-contrast MRI is the most promising technique for in-vivo characterization of carotid plaques. Multi-contrast image registration is essential for this application, because it corrects misalignments caused by patient motion during MRI acquisition. To date, it has not been determined which automatic method provides the best registration accuracy in carotid MRI. This study tries to answer this question by presenting an iterative coarse-to-fine algorithm that co-registers multi-contrast images of carotid arteries using three similarity metrics: Correlation Ratio (CR), Mutual Information (MI) and Gradient MI (GMI). The registration algorithm is first applied on the entire images and then only on the Region of Interest (ROI) of the carotid arteries using sub-pixel accuracy. The ROI is defined by an automatic carotid detection algorithm, which was tested on a group of 20 patients with different types of atherosclerotic plaques (sensitivity 91% and specificity 88%). Automatic registration was compared with image alignment obtained by manual operators (clinically qualified vascular specialists). Registration accuracies were measured using a novel MRI validation procedure, in which the gold standard is represented by in-plane rigid transformations applied by the MRI system to mimic neck movements. Overall, automatic methods (GMI = 181 ± 104 μm) produced lower registration errors than manual operators (365 ± 102 μm). GMI performed slightly better than CR and MI, suggesting that anatomical information improves registration accuracy in the carotid ROI. © 2010 Copyright SPIE - The International Society for Optical Engineering.
first_indexed 2024-03-06T22:15:12Z
format Conference item
id oxford-uuid:5328d485-9d0a-480f-93bb-6b24f7487f5c
institution University of Oxford
last_indexed 2024-03-06T22:15:12Z
publishDate 2010
record_format dspace
spelling oxford-uuid:5328d485-9d0a-480f-93bb-6b24f7487f5c2022-03-26T16:29:51ZMulti-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal SubjectsConference itemhttp://purl.org/coar/resource_type/c_5794uuid:5328d485-9d0a-480f-93bb-6b24f7487f5cSymplectic Elements at Oxford2010Biasiolli, LNoble, ARobson, MClinical studies on atherosclerosis agree that multi-contrast MRI is the most promising technique for in-vivo characterization of carotid plaques. Multi-contrast image registration is essential for this application, because it corrects misalignments caused by patient motion during MRI acquisition. To date, it has not been determined which automatic method provides the best registration accuracy in carotid MRI. This study tries to answer this question by presenting an iterative coarse-to-fine algorithm that co-registers multi-contrast images of carotid arteries using three similarity metrics: Correlation Ratio (CR), Mutual Information (MI) and Gradient MI (GMI). The registration algorithm is first applied on the entire images and then only on the Region of Interest (ROI) of the carotid arteries using sub-pixel accuracy. The ROI is defined by an automatic carotid detection algorithm, which was tested on a group of 20 patients with different types of atherosclerotic plaques (sensitivity 91% and specificity 88%). Automatic registration was compared with image alignment obtained by manual operators (clinically qualified vascular specialists). Registration accuracies were measured using a novel MRI validation procedure, in which the gold standard is represented by in-plane rigid transformations applied by the MRI system to mimic neck movements. Overall, automatic methods (GMI = 181 ± 104 μm) produced lower registration errors than manual operators (365 ± 102 μm). GMI performed slightly better than CR and MI, suggesting that anatomical information improves registration accuracy in the carotid ROI. © 2010 Copyright SPIE - The International Society for Optical Engineering.
spellingShingle Biasiolli, L
Noble, A
Robson, M
Multi-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal Subjects
title Multi-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal Subjects
title_full Multi-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal Subjects
title_fullStr Multi-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal Subjects
title_full_unstemmed Multi-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal Subjects
title_short Multi-Contrast MRI Registration of Carotid Arteries in Atherosclerotic and Normal Subjects
title_sort multi contrast mri registration of carotid arteries in atherosclerotic and normal subjects
work_keys_str_mv AT biasiollil multicontrastmriregistrationofcarotidarteriesinatheroscleroticandnormalsubjects
AT noblea multicontrastmriregistrationofcarotidarteriesinatheroscleroticandnormalsubjects
AT robsonm multicontrastmriregistrationofcarotidarteriesinatheroscleroticandnormalsubjects