Impact of rotor-casing effusion cooling on turbine performance and operating point: an experimental, computational, and theoretical study
It is known that a secondary effect of rotor-casing effusion cooling is to modify and potentially spoil the rotor over-tip leakage flow. Studies have shown both positive and negative impacts on high-pressure (HP) stage aerodynamic performance and heat transfer, although there remains no consensus on...
المؤلفون الرئيسيون: | Adams, MG, Adami, P, Collins, M, Beard, PF, Chana, KS, Povey, T |
---|---|
التنسيق: | Journal article |
اللغة: | English |
منشور في: |
American Society of Mechanical Engineers
2021
|
مواد مشابهة
-
Effect of a combined hot-streak and swirl profile on cooled 1.5-stage turbine aerodynamics: an experimental and computational study
حسب: Adams, MG, وآخرون
منشور في: (2021) -
Commissioning of a combined hot-streak and swirl profile generator in a transonic turbine test facility
حسب: Adams, MG, وآخرون
منشور في: (2020) -
Application of film cooling to an unshrouded HP turbine casing
حسب: Collins, M, وآخرون
منشور في: (2016) -
A review of high-speed rotating HP turbine heat transfer and cooling studies over the last decade in the Oxford Turbine Research Facility
حسب: Falsetti, C, وآخرون
منشور في: (2022) -
Application of film cooling to an unshrouded high-pressure turbine casing
حسب: Collins, M, وآخرون
منشور في: (2017)