Fluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulation

<p><b>BACKGROUND:</b> In the recent development of regenerative medicine, the low yields of progenitor cells have limited the large-scale clinical applications. To overcome the limitation, a novel fluidized bed bioreactor has emerged. However, a detailed understanding of the fluid...

Full description

Bibliographic Details
Main Authors: Huang, Z, Odeleye, A, Ye, H, Cui, Z, Yang, A
Format: Journal article
Published: Wiley 2018
_version_ 1797069548367642624
author Huang, Z
Odeleye, A
Ye, H
Cui, Z
Yang, A
author_facet Huang, Z
Odeleye, A
Ye, H
Cui, Z
Yang, A
author_sort Huang, Z
collection OXFORD
description <p><b>BACKGROUND:</b> In the recent development of regenerative medicine, the low yields of progenitor cells have limited the large-scale clinical applications. To overcome the limitation, a novel fluidized bed bioreactor has emerged. However, a detailed understanding of the fluid dynamics is still lacking. </p><p><b>RESULTS:</b> A three-dimensional modelling approach that couples computational fluid dynamics (CFD) and discrete element method (DEM) was used to simulate the liquid and solid flows in a bioreactor being designed for stem cells expansion. The model was validated by comparing the simulation results with literature experimental data (Chem. Eng. Sci. 60: 1889-1900 (2005)), which showed a good agreement. Using the validated model, the effects of the superficial liquid velocity, particle size and particle density on the solids volume fraction, shear stress on the particles and liquid-solid mass transfer coefficient of dissolved oxygen and glucose were analyzed. </p><p><b>CONCLUSIONS:</b> Simulation results show that particle size and density have an important impact on the shear stress distribution, and that the liquid velocity affects the shear stress distribution rather modestly when its value is beyond the minimum fluidization velocity. The liquid-particle mass transfer coefficient of dissolved oxygen and glucose can be improved by raising the liquid velocity, and the adoption of a high-density material allows the reactor to operate with higher liquid velocities before reaching shear stress heterogeneities. Furthermore, the two objectives, (i) maintaining lower and homogeneously distributed shear stress and (ii) improving mass transfer, pose conflicting requirements on certain design parameters which need to be carefully considered in the reactor design.</p>
first_indexed 2024-03-06T22:26:05Z
format Journal article
id oxford-uuid:56b4efca-4619-41c5-8cb7-9bbf25cc95ec
institution University of Oxford
last_indexed 2024-03-06T22:26:05Z
publishDate 2018
publisher Wiley
record_format dspace
spelling oxford-uuid:56b4efca-4619-41c5-8cb7-9bbf25cc95ec2022-03-26T16:52:03ZFluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulationJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:56b4efca-4619-41c5-8cb7-9bbf25cc95ecSymplectic Elements at OxfordWiley2018Huang, ZOdeleye, AYe, HCui, ZYang, A <p><b>BACKGROUND:</b> In the recent development of regenerative medicine, the low yields of progenitor cells have limited the large-scale clinical applications. To overcome the limitation, a novel fluidized bed bioreactor has emerged. However, a detailed understanding of the fluid dynamics is still lacking. </p><p><b>RESULTS:</b> A three-dimensional modelling approach that couples computational fluid dynamics (CFD) and discrete element method (DEM) was used to simulate the liquid and solid flows in a bioreactor being designed for stem cells expansion. The model was validated by comparing the simulation results with literature experimental data (Chem. Eng. Sci. 60: 1889-1900 (2005)), which showed a good agreement. Using the validated model, the effects of the superficial liquid velocity, particle size and particle density on the solids volume fraction, shear stress on the particles and liquid-solid mass transfer coefficient of dissolved oxygen and glucose were analyzed. </p><p><b>CONCLUSIONS:</b> Simulation results show that particle size and density have an important impact on the shear stress distribution, and that the liquid velocity affects the shear stress distribution rather modestly when its value is beyond the minimum fluidization velocity. The liquid-particle mass transfer coefficient of dissolved oxygen and glucose can be improved by raising the liquid velocity, and the adoption of a high-density material allows the reactor to operate with higher liquid velocities before reaching shear stress heterogeneities. Furthermore, the two objectives, (i) maintaining lower and homogeneously distributed shear stress and (ii) improving mass transfer, pose conflicting requirements on certain design parameters which need to be carefully considered in the reactor design.</p>
spellingShingle Huang, Z
Odeleye, A
Ye, H
Cui, Z
Yang, A
Fluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulation
title Fluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulation
title_full Fluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulation
title_fullStr Fluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulation
title_full_unstemmed Fluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulation
title_short Fluid dynamic characterization of a fluidized‐bed perfusion bioreactor with CFD–DEM simulation
title_sort fluid dynamic characterization of a fluidized bed perfusion bioreactor with cfd dem simulation
work_keys_str_mv AT huangz fluiddynamiccharacterizationofafluidizedbedperfusionbioreactorwithcfddemsimulation
AT odeleyea fluiddynamiccharacterizationofafluidizedbedperfusionbioreactorwithcfddemsimulation
AT yeh fluiddynamiccharacterizationofafluidizedbedperfusionbioreactorwithcfddemsimulation
AT cuiz fluiddynamiccharacterizationofafluidizedbedperfusionbioreactorwithcfddemsimulation
AT yanga fluiddynamiccharacterizationofafluidizedbedperfusionbioreactorwithcfddemsimulation