An improved understanding of ultrasound contrast agent (UCA) shell rupture is required to optimize therapeutic and diagnostic use. This experimental and theoretical study aims to explore the mechanism of UCA shell rupture by determining thresholds as a function of ultrasonic excitation parameters (d...

Celý popis

Podrobná bibliografie
Hlavní autoři: Ammi, A, Cleveland, R, Mamou, J, Wang, G, Bridal, S, O'Brien, W, IEEE
Médium: Journal article
Jazyk:English
Vydáno: 2005
_version_ 1826274171531821056
author Ammi, A
Cleveland, R
Mamou, J
Wang, G
Bridal, S
O'Brien, W
IEEE
author_facet Ammi, A
Cleveland, R
Mamou, J
Wang, G
Bridal, S
O'Brien, W
IEEE
author_sort Ammi, A
collection OXFORD
description An improved understanding of ultrasound contrast agent (UCA) shell rupture is required to optimize therapeutic and diagnostic use. This experimental and theoretical study aims to explore the mechanism of UCA shell rupture by determining thresholds as a function of ultrasonic excitation parameters (driving frequency, pulse duration, and peak rarefactional pressure). The experimental setup is based on a passive cavitation detection system described in previous work. However, this system has been modified to allow simultaneous acquisition of the signals received with the 13-MHz passive receiver and the signals incident upon the lower frequency (0.9, 2.8 and 4.6 MHz) transmitting transducer functioning in the pulse-echo mode. Post-excitation signals were used to detect rupture thresholds. By allowing acquisition of the signals received by the insonifying transducer (pulse-echo during the excitation and passively at post-excitation) additional information is obtained within a frequency range and a transmission/reception configuration typical of ultrasonic diagnostic imaging. Data are analyzed to estimates the incident peak rarefactional pressure leading to 50% destruction. Comparison of experimental results with microbubble dynamics predicted using the Modified Herring equation was used to explore microbubble rupture indices based on radial expansion and peak velocity. © 2005 IEEE.
first_indexed 2024-03-06T22:39:23Z
format Journal article
id oxford-uuid:5b0084bc-209d-4745-939a-0bf7104c649c
institution University of Oxford
language English
last_indexed 2024-03-06T22:39:23Z
publishDate 2005
record_format dspace
spelling oxford-uuid:5b0084bc-209d-4745-939a-0bf7104c649c2022-03-26T17:19:26ZDouble passive cavitation detection of Optison (TM) shell ruptureJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:5b0084bc-209d-4745-939a-0bf7104c649cEnglishSymplectic Elements at Oxford2005Ammi, ACleveland, RMamou, JWang, GBridal, SO'Brien, WIEEEAn improved understanding of ultrasound contrast agent (UCA) shell rupture is required to optimize therapeutic and diagnostic use. This experimental and theoretical study aims to explore the mechanism of UCA shell rupture by determining thresholds as a function of ultrasonic excitation parameters (driving frequency, pulse duration, and peak rarefactional pressure). The experimental setup is based on a passive cavitation detection system described in previous work. However, this system has been modified to allow simultaneous acquisition of the signals received with the 13-MHz passive receiver and the signals incident upon the lower frequency (0.9, 2.8 and 4.6 MHz) transmitting transducer functioning in the pulse-echo mode. Post-excitation signals were used to detect rupture thresholds. By allowing acquisition of the signals received by the insonifying transducer (pulse-echo during the excitation and passively at post-excitation) additional information is obtained within a frequency range and a transmission/reception configuration typical of ultrasonic diagnostic imaging. Data are analyzed to estimates the incident peak rarefactional pressure leading to 50% destruction. Comparison of experimental results with microbubble dynamics predicted using the Modified Herring equation was used to explore microbubble rupture indices based on radial expansion and peak velocity. © 2005 IEEE.
spellingShingle Ammi, A
Cleveland, R
Mamou, J
Wang, G
Bridal, S
O'Brien, W
IEEE
Double passive cavitation detection of Optison (TM) shell rupture
title Double passive cavitation detection of Optison (TM) shell rupture
title_full Double passive cavitation detection of Optison (TM) shell rupture
title_fullStr Double passive cavitation detection of Optison (TM) shell rupture
title_full_unstemmed Double passive cavitation detection of Optison (TM) shell rupture
title_short Double passive cavitation detection of Optison (TM) shell rupture
title_sort double passive cavitation detection of optison tm shell rupture
work_keys_str_mv AT ammia doublepassivecavitationdetectionofoptisontmshellrupture
AT clevelandr doublepassivecavitationdetectionofoptisontmshellrupture
AT mamouj doublepassivecavitationdetectionofoptisontmshellrupture
AT wangg doublepassivecavitationdetectionofoptisontmshellrupture
AT bridals doublepassivecavitationdetectionofoptisontmshellrupture
AT obrienw doublepassivecavitationdetectionofoptisontmshellrupture
AT ieee doublepassivecavitationdetectionofoptisontmshellrupture