Measurement of the muon stopping power in lead tungstate
A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectatio...
Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
2010
|
_version_ | 1826274606555594752 |
---|---|
author | Chatrchyan, S Khachatryan, V Sirunyan, A Adam, W Arnold, B Bergauer, H Bergauer, T Dragicevic, M Eichberger, M Erö, J Friedl, M Frühwirth, R Ghete, V Hammer, J Hansel, S Hoch, M Hörmann, N Hrubec, J Jeitler, M Kasieczka, G Kastner, K Krammer, M Liko, D De Magrans Abril, I Mikulec, I |
author_facet | Chatrchyan, S Khachatryan, V Sirunyan, A Adam, W Arnold, B Bergauer, H Bergauer, T Dragicevic, M Eichberger, M Erö, J Friedl, M Frühwirth, R Ghete, V Hammer, J Hansel, S Hoch, M Hörmann, N Hrubec, J Jeitler, M Kasieczka, G Kastner, K Krammer, M Liko, D De Magrans Abril, I Mikulec, I |
author_sort | Chatrchyan, S |
collection | OXFORD |
description | A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5-68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA. |
first_indexed | 2024-03-06T22:46:00Z |
format | Journal article |
id | oxford-uuid:5d334ee6-7d6c-45a6-b4dd-e744e69bd785 |
institution | University of Oxford |
language | English |
last_indexed | 2024-03-06T22:46:00Z |
publishDate | 2010 |
record_format | dspace |
spelling | oxford-uuid:5d334ee6-7d6c-45a6-b4dd-e744e69bd7852022-03-26T17:32:57ZMeasurement of the muon stopping power in lead tungstateJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:5d334ee6-7d6c-45a6-b4dd-e744e69bd785EnglishSymplectic Elements at Oxford2010Chatrchyan, SKhachatryan, VSirunyan, AAdam, WArnold, BBergauer, HBergauer, TDragicevic, MEichberger, MErö, JFriedl, MFrühwirth, RGhete, VHammer, JHansel, SHoch, MHörmann, NHrubec, JJeitler, MKasieczka, GKastner, KKrammer, MLiko, DDe Magrans Abril, IMikulec, IA large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5-68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA. |
spellingShingle | Chatrchyan, S Khachatryan, V Sirunyan, A Adam, W Arnold, B Bergauer, H Bergauer, T Dragicevic, M Eichberger, M Erö, J Friedl, M Frühwirth, R Ghete, V Hammer, J Hansel, S Hoch, M Hörmann, N Hrubec, J Jeitler, M Kasieczka, G Kastner, K Krammer, M Liko, D De Magrans Abril, I Mikulec, I Measurement of the muon stopping power in lead tungstate |
title | Measurement of the muon stopping power in lead tungstate |
title_full | Measurement of the muon stopping power in lead tungstate |
title_fullStr | Measurement of the muon stopping power in lead tungstate |
title_full_unstemmed | Measurement of the muon stopping power in lead tungstate |
title_short | Measurement of the muon stopping power in lead tungstate |
title_sort | measurement of the muon stopping power in lead tungstate |
work_keys_str_mv | AT chatrchyans measurementofthemuonstoppingpowerinleadtungstate AT khachatryanv measurementofthemuonstoppingpowerinleadtungstate AT sirunyana measurementofthemuonstoppingpowerinleadtungstate AT adamw measurementofthemuonstoppingpowerinleadtungstate AT arnoldb measurementofthemuonstoppingpowerinleadtungstate AT bergauerh measurementofthemuonstoppingpowerinleadtungstate AT bergauert measurementofthemuonstoppingpowerinleadtungstate AT dragicevicm measurementofthemuonstoppingpowerinleadtungstate AT eichbergerm measurementofthemuonstoppingpowerinleadtungstate AT eroj measurementofthemuonstoppingpowerinleadtungstate AT friedlm measurementofthemuonstoppingpowerinleadtungstate AT fruhwirthr measurementofthemuonstoppingpowerinleadtungstate AT ghetev measurementofthemuonstoppingpowerinleadtungstate AT hammerj measurementofthemuonstoppingpowerinleadtungstate AT hansels measurementofthemuonstoppingpowerinleadtungstate AT hochm measurementofthemuonstoppingpowerinleadtungstate AT hormannn measurementofthemuonstoppingpowerinleadtungstate AT hrubecj measurementofthemuonstoppingpowerinleadtungstate AT jeitlerm measurementofthemuonstoppingpowerinleadtungstate AT kasieczkag measurementofthemuonstoppingpowerinleadtungstate AT kastnerk measurementofthemuonstoppingpowerinleadtungstate AT krammerm measurementofthemuonstoppingpowerinleadtungstate AT likod measurementofthemuonstoppingpowerinleadtungstate AT demagransabrili measurementofthemuonstoppingpowerinleadtungstate AT mikuleci measurementofthemuonstoppingpowerinleadtungstate |