Understanding thermal unsteadiness in engine representative flows and improved methodologies for derived heat transfer calculations using thin-film gauges
The Oxford Turbine Research Facility (OTRF) is a high-speed rotating transient test facility, which allows unsteady aerodynamic and heat transfer measurements at engine representative conditions. In addition, a variety of inlet temperature profiles can be simulated in the rig including radial distor...
Main Authors: | Singh, D, Beard, PF, Cardwell, D, Chana, KS |
---|---|
Format: | Journal article |
Language: | English |
Published: |
American Society of Mechanical Engineers
2023
|
Similar Items
-
Investigation of a high-pressure turbine stage in a high-speed rotating transient test facility for rotor tip study and a parametric study for improved heat transfer calculation
by: Singh, D, et al.
Published: (2022) -
An aerodynamic investigation of a high-pressure turbine using rotor casing static pressure measurements at engine representative conditions with different tip designs, tip gaps and inlet temperature profiles
by: Singh, D, et al.
Published: (2024) -
A review of high-speed rotating HP turbine heat transfer and cooling studies over the last decade in the Oxford Turbine Research Facility
by: Falsetti, C, et al.
Published: (2022) -
An aerodynamic investigation of a high-pressure turbine using rotor casing static pressure measurements at engine representative conditions with different tip designs, tip gaps, and inlet temperature profiles
by: Singh, D, et al.
Published: (2025) -
Computational and experimental study of a platinum thin-film based oil condition and contamination sensor
by: Sridhar, V, et al.
Published: (2017)