Evaluation of non-Gaussian diffusion in cardiac MRI

<h4>Purpose</h4> <p>The diffusion tensor model assumes Gaussian diffusion and is widely applied in cardiac diffusion MRI. However, diffusion in biological tissue deviates from a Gaussian profile as a result of hindrance and restriction from cell and tissue microstructure, and may...

Full beskrivning

Bibliografiska uppgifter
Huvudupphovsmän: McClymont, D, Teh, I, Carruth, E, Omens, J, McCulloch, A, Whittington, H, Kohl, P, Grau, V, Schneider, J
Materialtyp: Journal article
Publicerad: Wiley 2016
_version_ 1826277088177422336
author McClymont, D
Teh, I
Carruth, E
Omens, J
McCulloch, A
Whittington, H
Kohl, P
Grau, V
Schneider, J
author_facet McClymont, D
Teh, I
Carruth, E
Omens, J
McCulloch, A
Whittington, H
Kohl, P
Grau, V
Schneider, J
author_sort McClymont, D
collection OXFORD
description <h4>Purpose</h4> <p>The diffusion tensor model assumes Gaussian diffusion and is widely applied in cardiac diffusion MRI. However, diffusion in biological tissue deviates from a Gaussian profile as a result of hindrance and restriction from cell and tissue microstructure, and may be quantified better by non-Gaussian modeling. The aimof this work was to investigate nonGaussian diffusion in healthy and hypertrophic hearts.</p> <h4>Methods</h4> <p>Thirteen rat hearts (five healthy, four sham, four hypertrophic) were imaged ex vivo. Diffusion-weighted images were acquired at b-values up to 10,000 s/mm^2. Models of diffusion were fit to the data and ranked based on the Akaike Information Criterion.</p> <h4>Results</h4> <p>The diffusion tensor was ranked best at b-values up to 2,000 s/mm^2, but reflected the signal poorly in the high b-value regime, in which the best model was a non-Gaussian ‘beta distribution’ model. While there is considerable overlap in apparent diffusivities between the healthy, sham and hypertrophic hearts, diffusion kurtosis and skewness in the hypertrophic hearts were more than 20% higher in the sheetlet and sheetlet-normal directions.</p> <h4>Conclusion</h4> <p>Non-Gaussian diffusion models have a higher sensitivity for the detection of hypertrophy compared to the Gaussian model. In particular, diffusion kurtosis may serve as a useful biomarker for characterization of disease and remodeling in the heart.</p>
first_indexed 2024-03-06T23:23:38Z
format Journal article
id oxford-uuid:69a0ee00-1ddd-4cb8-b51b-66e98cc0c00d
institution University of Oxford
last_indexed 2024-03-06T23:23:38Z
publishDate 2016
publisher Wiley
record_format dspace
spelling oxford-uuid:69a0ee00-1ddd-4cb8-b51b-66e98cc0c00d2022-03-26T18:52:19ZEvaluation of non-Gaussian diffusion in cardiac MRIJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:69a0ee00-1ddd-4cb8-b51b-66e98cc0c00dSymplectic Elements at OxfordWiley2016McClymont, DTeh, ICarruth, EOmens, JMcCulloch, AWhittington, HKohl, PGrau, VSchneider, J <h4>Purpose</h4> <p>The diffusion tensor model assumes Gaussian diffusion and is widely applied in cardiac diffusion MRI. However, diffusion in biological tissue deviates from a Gaussian profile as a result of hindrance and restriction from cell and tissue microstructure, and may be quantified better by non-Gaussian modeling. The aimof this work was to investigate nonGaussian diffusion in healthy and hypertrophic hearts.</p> <h4>Methods</h4> <p>Thirteen rat hearts (five healthy, four sham, four hypertrophic) were imaged ex vivo. Diffusion-weighted images were acquired at b-values up to 10,000 s/mm^2. Models of diffusion were fit to the data and ranked based on the Akaike Information Criterion.</p> <h4>Results</h4> <p>The diffusion tensor was ranked best at b-values up to 2,000 s/mm^2, but reflected the signal poorly in the high b-value regime, in which the best model was a non-Gaussian ‘beta distribution’ model. While there is considerable overlap in apparent diffusivities between the healthy, sham and hypertrophic hearts, diffusion kurtosis and skewness in the hypertrophic hearts were more than 20% higher in the sheetlet and sheetlet-normal directions.</p> <h4>Conclusion</h4> <p>Non-Gaussian diffusion models have a higher sensitivity for the detection of hypertrophy compared to the Gaussian model. In particular, diffusion kurtosis may serve as a useful biomarker for characterization of disease and remodeling in the heart.</p>
spellingShingle McClymont, D
Teh, I
Carruth, E
Omens, J
McCulloch, A
Whittington, H
Kohl, P
Grau, V
Schneider, J
Evaluation of non-Gaussian diffusion in cardiac MRI
title Evaluation of non-Gaussian diffusion in cardiac MRI
title_full Evaluation of non-Gaussian diffusion in cardiac MRI
title_fullStr Evaluation of non-Gaussian diffusion in cardiac MRI
title_full_unstemmed Evaluation of non-Gaussian diffusion in cardiac MRI
title_short Evaluation of non-Gaussian diffusion in cardiac MRI
title_sort evaluation of non gaussian diffusion in cardiac mri
work_keys_str_mv AT mcclymontd evaluationofnongaussiandiffusionincardiacmri
AT tehi evaluationofnongaussiandiffusionincardiacmri
AT carruthe evaluationofnongaussiandiffusionincardiacmri
AT omensj evaluationofnongaussiandiffusionincardiacmri
AT mccullocha evaluationofnongaussiandiffusionincardiacmri
AT whittingtonh evaluationofnongaussiandiffusionincardiacmri
AT kohlp evaluationofnongaussiandiffusionincardiacmri
AT grauv evaluationofnongaussiandiffusionincardiacmri
AT schneiderj evaluationofnongaussiandiffusionincardiacmri