A Monte-Carlo method for interface dosimetry of beta emitters.

Biologically targeted radiotherapy optimization requires accurate dose estimation, from macroscopic to cellular/subcellular dimensions. In particular, dose perturbations produced at interfaces between dissimilar media could affect therapy outcome. The magnitude of these perturbations depends on a co...

Ful tanımlama

Detaylı Bibliyografya
Asıl Yazarlar: Buffa, F, Verhaegen, F, Flux, G, Dearnaley, D
Materyal Türü: Journal article
Dil:English
Baskı/Yayın Bilgisi: 2003
_version_ 1826277954100920320
author Buffa, F
Verhaegen, F
Flux, G
Dearnaley, D
author_facet Buffa, F
Verhaegen, F
Flux, G
Dearnaley, D
author_sort Buffa, F
collection OXFORD
description Biologically targeted radiotherapy optimization requires accurate dose estimation, from macroscopic to cellular/subcellular dimensions. In particular, dose perturbations produced at interfaces between dissimilar media could affect therapy outcome. The magnitude of these perturbations depends on a complex set of parameters. This study investigates perturbations on electron dose for materials with atomic numbers (Z) up to 79 (79Au) at their interface with water as a function of Z, energy, distance from interface and geometry. A Monte-Carlo method that produces absorbed dose distributions in a voxel geometry has been developed using EGSnrc transport routines. Heterogeneous media and activity distributions can be input into this code. The backscatter dose factor (BSDF), which quantifies interface dose perturbations, was estimated using this code. The BSDF magnitude ranged from approximately 3% to approximately 50%, depending on source energy and Z. The BSDF decreased with increasing energy and showed a logarithmic dependence on Z. Empirical functions were fit to the results, that could be used to correct dose calculations performed using dose-point-kernels estimated in water, to cases involving different scattering materials. The BSDF was found to be highly dependent on interface geometry and scoring volume; thus it is vital that BSDFs are used only in geometry conditions that are similar to those in which they were originally produced.
first_indexed 2024-03-06T23:36:40Z
format Journal article
id oxford-uuid:6de680b9-a3fe-4f39-aa23-8f4038e88ec3
institution University of Oxford
language English
last_indexed 2024-03-06T23:36:40Z
publishDate 2003
record_format dspace
spelling oxford-uuid:6de680b9-a3fe-4f39-aa23-8f4038e88ec32022-03-26T19:20:46ZA Monte-Carlo method for interface dosimetry of beta emitters.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:6de680b9-a3fe-4f39-aa23-8f4038e88ec3EnglishSymplectic Elements at Oxford2003Buffa, FVerhaegen, FFlux, GDearnaley, DBiologically targeted radiotherapy optimization requires accurate dose estimation, from macroscopic to cellular/subcellular dimensions. In particular, dose perturbations produced at interfaces between dissimilar media could affect therapy outcome. The magnitude of these perturbations depends on a complex set of parameters. This study investigates perturbations on electron dose for materials with atomic numbers (Z) up to 79 (79Au) at their interface with water as a function of Z, energy, distance from interface and geometry. A Monte-Carlo method that produces absorbed dose distributions in a voxel geometry has been developed using EGSnrc transport routines. Heterogeneous media and activity distributions can be input into this code. The backscatter dose factor (BSDF), which quantifies interface dose perturbations, was estimated using this code. The BSDF magnitude ranged from approximately 3% to approximately 50%, depending on source energy and Z. The BSDF decreased with increasing energy and showed a logarithmic dependence on Z. Empirical functions were fit to the results, that could be used to correct dose calculations performed using dose-point-kernels estimated in water, to cases involving different scattering materials. The BSDF was found to be highly dependent on interface geometry and scoring volume; thus it is vital that BSDFs are used only in geometry conditions that are similar to those in which they were originally produced.
spellingShingle Buffa, F
Verhaegen, F
Flux, G
Dearnaley, D
A Monte-Carlo method for interface dosimetry of beta emitters.
title A Monte-Carlo method for interface dosimetry of beta emitters.
title_full A Monte-Carlo method for interface dosimetry of beta emitters.
title_fullStr A Monte-Carlo method for interface dosimetry of beta emitters.
title_full_unstemmed A Monte-Carlo method for interface dosimetry of beta emitters.
title_short A Monte-Carlo method for interface dosimetry of beta emitters.
title_sort monte carlo method for interface dosimetry of beta emitters
work_keys_str_mv AT buffaf amontecarlomethodforinterfacedosimetryofbetaemitters
AT verhaegenf amontecarlomethodforinterfacedosimetryofbetaemitters
AT fluxg amontecarlomethodforinterfacedosimetryofbetaemitters
AT dearnaleyd amontecarlomethodforinterfacedosimetryofbetaemitters
AT buffaf montecarlomethodforinterfacedosimetryofbetaemitters
AT verhaegenf montecarlomethodforinterfacedosimetryofbetaemitters
AT fluxg montecarlomethodforinterfacedosimetryofbetaemitters
AT dearnaleyd montecarlomethodforinterfacedosimetryofbetaemitters