Sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.

BACKGROUND AND OBJECTIVE: No consensus exists as to the benefit of pleural drainage in mechanically ventilated patients with conflicting data concerning the effects on gas exchange. We determined the effects on gas exchange over a 48-hour period of draining, by thoracocentesis, large volume pleural...

Full description

Bibliographic Details
Main Authors: Walden, A, Garrard, C, Salmon, J
Format: Journal article
Language:English
Published: 2010
_version_ 1797074922493706240
author Walden, A
Garrard, C
Salmon, J
author_facet Walden, A
Garrard, C
Salmon, J
author_sort Walden, A
collection OXFORD
description BACKGROUND AND OBJECTIVE: No consensus exists as to the benefit of pleural drainage in mechanically ventilated patients with conflicting data concerning the effects on gas exchange. We determined the effects on gas exchange over a 48-hour period of draining, by thoracocentesis, large volume pleural effusions. METHODS: A total of 15 thoracocenteses were performed in 10 mechanically ventilated patients with ultrasound evidence of pleural effusions predicted to be greater than 800 mL in volume. Gas exchange, mixed expired CO2, dynamic lung compliance, ventilator settings before procedure and at 30 min, 4, 8, 24 and 48 h were determined. Data were analysed using paired t-tests and repeated-measure anova. RESULTS: Following thoracocentesis there was a 40% increase in the PaO(2) from 82.0 +/- 10.6 mm Hg to 115.2 +/- 31.1 mm Hg (P < 0.05) with a 34% increase in the P:F ratio from 168.9 +/- 55.9 mm Hg to 237.8 +/- 72.6 mm Hg (P < 0.05). These effects were maintained for a period of 48 h. There was a correlation between the amount of fluid drained and the effects on oxygenation with an increase in the PaO(2) of 4 mm Hg for each 100 mL of pleural fluid drained. A-a gradients continued to improve over the course of the study together with a reduction in the dead space fraction and improved dynamic compliance. CONCLUSIONS: Drainage of large pleural effusions in mechanically ventilated patients leads to a significant improvement in gas exchange, and these effects are sustained for 48 h after the procedure supporting a role in the discontinuation of mechanical ventilation.
first_indexed 2024-03-06T23:43:16Z
format Journal article
id oxford-uuid:700aae06-49ed-46da-9539-bcf30d2cd0a0
institution University of Oxford
language English
last_indexed 2024-03-06T23:43:16Z
publishDate 2010
record_format dspace
spelling oxford-uuid:700aae06-49ed-46da-9539-bcf30d2cd0a02022-03-26T19:34:31ZSustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:700aae06-49ed-46da-9539-bcf30d2cd0a0EnglishSymplectic Elements at Oxford2010Walden, AGarrard, CSalmon, J BACKGROUND AND OBJECTIVE: No consensus exists as to the benefit of pleural drainage in mechanically ventilated patients with conflicting data concerning the effects on gas exchange. We determined the effects on gas exchange over a 48-hour period of draining, by thoracocentesis, large volume pleural effusions. METHODS: A total of 15 thoracocenteses were performed in 10 mechanically ventilated patients with ultrasound evidence of pleural effusions predicted to be greater than 800 mL in volume. Gas exchange, mixed expired CO2, dynamic lung compliance, ventilator settings before procedure and at 30 min, 4, 8, 24 and 48 h were determined. Data were analysed using paired t-tests and repeated-measure anova. RESULTS: Following thoracocentesis there was a 40% increase in the PaO(2) from 82.0 +/- 10.6 mm Hg to 115.2 +/- 31.1 mm Hg (P < 0.05) with a 34% increase in the P:F ratio from 168.9 +/- 55.9 mm Hg to 237.8 +/- 72.6 mm Hg (P < 0.05). These effects were maintained for a period of 48 h. There was a correlation between the amount of fluid drained and the effects on oxygenation with an increase in the PaO(2) of 4 mm Hg for each 100 mL of pleural fluid drained. A-a gradients continued to improve over the course of the study together with a reduction in the dead space fraction and improved dynamic compliance. CONCLUSIONS: Drainage of large pleural effusions in mechanically ventilated patients leads to a significant improvement in gas exchange, and these effects are sustained for 48 h after the procedure supporting a role in the discontinuation of mechanical ventilation.
spellingShingle Walden, A
Garrard, C
Salmon, J
Sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.
title Sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.
title_full Sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.
title_fullStr Sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.
title_full_unstemmed Sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.
title_short Sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients.
title_sort sustained effects of thoracocentesis on oxygenation in mechanically ventilated patients
work_keys_str_mv AT waldena sustainedeffectsofthoracocentesisonoxygenationinmechanicallyventilatedpatients
AT garrardc sustainedeffectsofthoracocentesisonoxygenationinmechanicallyventilatedpatients
AT salmonj sustainedeffectsofthoracocentesisonoxygenationinmechanicallyventilatedpatients