IP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDS

Beam-beam background impacts on the IP BPM are studied for the CLIC machine. The large number of coherent pairs (1.8 × 108 charges per BPM strip per bunch crossing) for the CLIC-G default parameter set, potentially leads to a large secondary emission in the BPM strips. Detailed GuineaPig++ and Geant...

Cur síos iomlán

Sonraí bibleagrafaíochta
Príomhchruthaitheoirí: Hartin, A, Clarke, C, Swinson, C, Burrows, P, Christian, G, Constance, B, Apsimon, R, Khah, H, Perry, C, Kalinin, A
Formáid: Conference item
Foilsithe / Cruthaithe: European Physical Society Accelerator Group (EPS-AG) 2008
_version_ 1826279592269185024
author Hartin, A
Clarke, C
Swinson, C
Burrows, P
Christian, G
Constance, B
Apsimon, R
Khah, H
Perry, C
Kalinin, A
author_facet Hartin, A
Clarke, C
Swinson, C
Burrows, P
Christian, G
Constance, B
Apsimon, R
Khah, H
Perry, C
Kalinin, A
author_sort Hartin, A
collection OXFORD
description Beam-beam background impacts on the IP BPM are studied for the CLIC machine. The large number of coherent pairs (1.8 × 108 charges per BPM strip per bunch crossing) for the CLIC-G default parameter set, potentially leads to a large secondary emission in the BPM strips. Detailed GuineaPig++ and Geant studies reveal, however, that the coherent pairs travel down the extraction line without significant secondary showering. Geant studies of the CLIC incoherent pairs show a flux of secondary emission two orders of magnitude less than that expected for the ILC 1 TeV high luminosity scheme. Since previous studies showed that FONT IP BPM signal distortion for the ILC was of no concern, then it can also be neglected at CLIC.
first_indexed 2024-03-07T00:01:03Z
format Conference item
id oxford-uuid:75f764a6-0c9b-4c98-b70b-176b5dcea724
institution University of Oxford
last_indexed 2024-03-07T00:01:03Z
publishDate 2008
publisher European Physical Society Accelerator Group (EPS-AG)
record_format dspace
spelling oxford-uuid:75f764a6-0c9b-4c98-b70b-176b5dcea7242022-03-26T20:12:41ZIP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDSConference itemhttp://purl.org/coar/resource_type/c_5794uuid:75f764a6-0c9b-4c98-b70b-176b5dcea724Symplectic Elements at OxfordEuropean Physical Society Accelerator Group (EPS-AG)2008Hartin, AClarke, CSwinson, CBurrows, PChristian, GConstance, BApsimon, RKhah, HPerry, CKalinin, ABeam-beam background impacts on the IP BPM are studied for the CLIC machine. The large number of coherent pairs (1.8 × 108 charges per BPM strip per bunch crossing) for the CLIC-G default parameter set, potentially leads to a large secondary emission in the BPM strips. Detailed GuineaPig++ and Geant studies reveal, however, that the coherent pairs travel down the extraction line without significant secondary showering. Geant studies of the CLIC incoherent pairs show a flux of secondary emission two orders of magnitude less than that expected for the ILC 1 TeV high luminosity scheme. Since previous studies showed that FONT IP BPM signal distortion for the ILC was of no concern, then it can also be neglected at CLIC.
spellingShingle Hartin, A
Clarke, C
Swinson, C
Burrows, P
Christian, G
Constance, B
Apsimon, R
Khah, H
Perry, C
Kalinin, A
IP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDS
title IP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDS
title_full IP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDS
title_fullStr IP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDS
title_full_unstemmed IP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDS
title_short IP BPM position error at CLIC due to secondary emission from beam-beam BACKGROUNDS
title_sort ip bpm position error at clic due to secondary emission from beam beam backgrounds
work_keys_str_mv AT hartina ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT clarkec ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT swinsonc ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT burrowsp ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT christiang ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT constanceb ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT apsimonr ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT khahh ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT perryc ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds
AT kalinina ipbpmpositionerroratclicduetosecondaryemissionfrombeambeambackgrounds