Image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement

<strong>Objective</strong> To develop an objective, image scoring system for pulsed wave Doppler measurement of maternal uterine and fetal umbilical arteries, and evaluate how the system compares with subjective assessment of the images. <strong>Methods</strong> As part of t...

Full description

Bibliographic Details
Main Authors: Molloholli, M, Napolitano, R, Ohuma, E, Ash, S, Wanyonyi, S, Cavallaro, A, Giudicepietro, A, Barros, F, Carvalho, M, Norris, S, Min, M, Zainab, G, Papageorghiou, A
Format: Journal article
Language:English
Published: John Wiley and Sons, Inc. 2018
_version_ 1797076239789326336
author Molloholli, M
Napolitano, R
Ohuma, E
Ash, S
Wanyonyi, S
Cavallaro, A
Giudicepietro, A
Barros, F
Carvalho, M
Norris, S
Min, M
Zainab, G
Papageorghiou, A
author_facet Molloholli, M
Napolitano, R
Ohuma, E
Ash, S
Wanyonyi, S
Cavallaro, A
Giudicepietro, A
Barros, F
Carvalho, M
Norris, S
Min, M
Zainab, G
Papageorghiou, A
author_sort Molloholli, M
collection OXFORD
description <strong>Objective</strong> To develop an objective, image scoring system for pulsed wave Doppler measurement of maternal uterine and fetal umbilical arteries, and evaluate how the system compares with subjective assessment of the images. <strong>Methods</strong> As part of the quality control strategy for the INTERGROWTH‐21st Project, we developed a scoring system based on six predefined criteria for uterine and umbilical artery pulsed wave Doppler measurement. The scoring system was compared to subjective assessment, which consisted simply of classifying an image as acceptable or unacceptable. Based on a sample size estimate, a total of 120 ultrasound images of umbilical and uterine artery Doppler were randomly selected from the INTERGROWTH‐21st database. Two independent reviewers evaluated these images in a blinded fashion both subjectively and using the six‐point scoring system. The percentage agreement and kappa statistic between the two methods were compared. <strong>Results</strong> The overall agreement between reviewers was higher for objective assessment using the scoring system (agreement: 85%, adjusted kappa: 0.70), than for subjective assessment (agreement: 70%, adjusted kappa: 0.47). The levels of agreement for the six components of the scoring system were: anatomical site (adjusted kappa: 0.97), sweep speed (0.88), magnification (0.77), velocity scale (0.68), image clarity (0.68), and angle of insonation (0.65). <strong>Conclusion</strong> In quality assessment of umbilical and uterine artery pulsed wave Doppler measurements, an objective six‐point image scoring system is associated with greater reproducibility than subjective assessment. We recommend this as the preferred method for quality control, audit and teaching.
first_indexed 2024-03-07T00:01:17Z
format Journal article
id oxford-uuid:760b5128-c785-4737-a5b6-032092e13e4a
institution University of Oxford
language English
last_indexed 2024-03-07T00:01:17Z
publishDate 2018
publisher John Wiley and Sons, Inc.
record_format dspace
spelling oxford-uuid:760b5128-c785-4737-a5b6-032092e13e4a2022-03-26T20:13:09ZImage scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurementJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:760b5128-c785-4737-a5b6-032092e13e4aEnglishSymplectic Elements at OxfordJohn Wiley and Sons, Inc.2018Molloholli, MNapolitano, ROhuma, EAsh, SWanyonyi, SCavallaro, AGiudicepietro, ABarros, FCarvalho, MNorris, SMin, MZainab, GPapageorghiou, A<strong>Objective</strong> To develop an objective, image scoring system for pulsed wave Doppler measurement of maternal uterine and fetal umbilical arteries, and evaluate how the system compares with subjective assessment of the images. <strong>Methods</strong> As part of the quality control strategy for the INTERGROWTH‐21st Project, we developed a scoring system based on six predefined criteria for uterine and umbilical artery pulsed wave Doppler measurement. The scoring system was compared to subjective assessment, which consisted simply of classifying an image as acceptable or unacceptable. Based on a sample size estimate, a total of 120 ultrasound images of umbilical and uterine artery Doppler were randomly selected from the INTERGROWTH‐21st database. Two independent reviewers evaluated these images in a blinded fashion both subjectively and using the six‐point scoring system. The percentage agreement and kappa statistic between the two methods were compared. <strong>Results</strong> The overall agreement between reviewers was higher for objective assessment using the scoring system (agreement: 85%, adjusted kappa: 0.70), than for subjective assessment (agreement: 70%, adjusted kappa: 0.47). The levels of agreement for the six components of the scoring system were: anatomical site (adjusted kappa: 0.97), sweep speed (0.88), magnification (0.77), velocity scale (0.68), image clarity (0.68), and angle of insonation (0.65). <strong>Conclusion</strong> In quality assessment of umbilical and uterine artery pulsed wave Doppler measurements, an objective six‐point image scoring system is associated with greater reproducibility than subjective assessment. We recommend this as the preferred method for quality control, audit and teaching.
spellingShingle Molloholli, M
Napolitano, R
Ohuma, E
Ash, S
Wanyonyi, S
Cavallaro, A
Giudicepietro, A
Barros, F
Carvalho, M
Norris, S
Min, M
Zainab, G
Papageorghiou, A
Image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement
title Image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement
title_full Image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement
title_fullStr Image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement
title_full_unstemmed Image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement
title_short Image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement
title_sort image scoring system for umbilical and uterine artery pulsed wave doppler ultrasound measurement
work_keys_str_mv AT mollohollim imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT napolitanor imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT ohumae imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT ashs imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT wanyonyis imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT cavallaroa imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT giudicepietroa imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT barrosf imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT carvalhom imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT norriss imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT minm imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT zainabg imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement
AT papageorghioua imagescoringsystemforumbilicalanduterinearterypulsedwavedopplerultrasoundmeasurement