Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry

Ceftriaxone is a cephalosporin antibiotic drug used as first-line treatment for a number of bacterial diseases. Ceftriaxone belongs to the third generation of cephalosporin and is available as an intramuscular or intravenous injection. Previously published pharmacokinetic studies have used high-perf...

Full description

Bibliographic Details
Main Authors: Wongchang, T, Winterberg, M, Tarning, J, Sriboonvorakul, N, Muangnoicharoen, S, Blessborn, D
Format: Journal article
Language:English
Published: F1000 2022
_version_ 1797110306197995520
author Wongchang, T
Winterberg, M
Tarning, J
Sriboonvorakul, N
Muangnoicharoen, S
Blessborn, D
author_facet Wongchang, T
Winterberg, M
Tarning, J
Sriboonvorakul, N
Muangnoicharoen, S
Blessborn, D
author_sort Wongchang, T
collection OXFORD
description Ceftriaxone is a cephalosporin antibiotic drug used as first-line treatment for a number of bacterial diseases. Ceftriaxone belongs to the third generation of cephalosporin and is available as an intramuscular or intravenous injection. Previously published pharmacokinetic studies have used high-performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) for the quantification of ceftriaxone. This study aimed to develop and validate a bioanalytical method for the quantification of ceftriaxone in human plasma using liquid chromatography followed by tandem mass spectrometry (LC-MS/MS). Sample preparation was performed by protein precipitation of 100 µl plasma sample in combination with phospholipid-removal techniques to minimize matrix interferences. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C18 column with 10 mM ammonium formate containing 2% formic acid: acetonitrile as mobile phase at a flow rate of 0.4 ml/min with a total run time of 10 minutes. Both the analyte and cefotaxime (internal standard) were detected using the positive electrospray ionization (ESI) mode and selected reaction monitoring (SRM) for the precursor-product ion transitions m/z 555.0→396.1 for ceftriaxone and 456.0→324.0 for cefotaxime. The method was validated over the concentration range of 1.01-200 μg/ml. Calibration response showed good linearity (correlation coefficient > 0.99) and matrix effects were within the ±15% limit in 6 different lots of sodium heparin plasma tested. However, citrate phosphate dextrose plasma resulted in a clear matrix enhancement of 24% at the low concentration level, which was not compensated for by the internal standard. Different anticoagulants (EDTA, heparin and citrate phosphate dextrose) also showed differences in recovery. Thus, it is important to use the same anticoagulant in calibration curves and clinical samples for analysis. The intra-assay and inter-assay precision were less than 5% and 10%, respectively, and therefore well within standard regulatory acceptance criterion of ±15%.
first_indexed 2024-03-07T07:53:07Z
format Journal article
id oxford-uuid:78deb9da-8e1d-47ae-9255-528cc9de0093
institution University of Oxford
language English
last_indexed 2024-03-07T07:53:07Z
publishDate 2022
publisher F1000
record_format dspace
spelling oxford-uuid:78deb9da-8e1d-47ae-9255-528cc9de00932023-08-03T11:44:57ZDetermination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometryJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:78deb9da-8e1d-47ae-9255-528cc9de0093EnglishSymplectic Elements at OxfordF10002022Wongchang, TWinterberg, MTarning, JSriboonvorakul, NMuangnoicharoen, SBlessborn, DCeftriaxone is a cephalosporin antibiotic drug used as first-line treatment for a number of bacterial diseases. Ceftriaxone belongs to the third generation of cephalosporin and is available as an intramuscular or intravenous injection. Previously published pharmacokinetic studies have used high-performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) for the quantification of ceftriaxone. This study aimed to develop and validate a bioanalytical method for the quantification of ceftriaxone in human plasma using liquid chromatography followed by tandem mass spectrometry (LC-MS/MS). Sample preparation was performed by protein precipitation of 100 µl plasma sample in combination with phospholipid-removal techniques to minimize matrix interferences. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C18 column with 10 mM ammonium formate containing 2% formic acid: acetonitrile as mobile phase at a flow rate of 0.4 ml/min with a total run time of 10 minutes. Both the analyte and cefotaxime (internal standard) were detected using the positive electrospray ionization (ESI) mode and selected reaction monitoring (SRM) for the precursor-product ion transitions m/z 555.0→396.1 for ceftriaxone and 456.0→324.0 for cefotaxime. The method was validated over the concentration range of 1.01-200 μg/ml. Calibration response showed good linearity (correlation coefficient > 0.99) and matrix effects were within the ±15% limit in 6 different lots of sodium heparin plasma tested. However, citrate phosphate dextrose plasma resulted in a clear matrix enhancement of 24% at the low concentration level, which was not compensated for by the internal standard. Different anticoagulants (EDTA, heparin and citrate phosphate dextrose) also showed differences in recovery. Thus, it is important to use the same anticoagulant in calibration curves and clinical samples for analysis. The intra-assay and inter-assay precision were less than 5% and 10%, respectively, and therefore well within standard regulatory acceptance criterion of ±15%.
spellingShingle Wongchang, T
Winterberg, M
Tarning, J
Sriboonvorakul, N
Muangnoicharoen, S
Blessborn, D
Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry
title Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry
title_full Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry
title_fullStr Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry
title_full_unstemmed Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry
title_short Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry
title_sort determination of ceftriaxone in human plasma using liquid chromatography tandem mass spectrometry
work_keys_str_mv AT wongchangt determinationofceftriaxoneinhumanplasmausingliquidchromatographytandemmassspectrometry
AT winterbergm determinationofceftriaxoneinhumanplasmausingliquidchromatographytandemmassspectrometry
AT tarningj determinationofceftriaxoneinhumanplasmausingliquidchromatographytandemmassspectrometry
AT sriboonvorakuln determinationofceftriaxoneinhumanplasmausingliquidchromatographytandemmassspectrometry
AT muangnoicharoens determinationofceftriaxoneinhumanplasmausingliquidchromatographytandemmassspectrometry
AT blessbornd determinationofceftriaxoneinhumanplasmausingliquidchromatographytandemmassspectrometry