Electroanalytical determination of trace chloride in room-temperature ionic liquids.

The electroanalytical quantification of chloride in [C4mim][BF4], [C4mim][NTf2], and [C4mim][PF6] ionic liquids has been explored using linear sweep and square wave voltammetry. Cathodic stripping voltammetry at a silver disk electrode is found to be the most sensitive. The methodology is based on f...

Full description

Bibliographic Details
Main Authors: Villagrán, C, Banks, C, Hardacre, C, Compton, R
Format: Journal article
Language:English
Published: 2004
_version_ 1797077162103144448
author Villagrán, C
Banks, C
Hardacre, C
Compton, R
author_facet Villagrán, C
Banks, C
Hardacre, C
Compton, R
author_sort Villagrán, C
collection OXFORD
description The electroanalytical quantification of chloride in [C4mim][BF4], [C4mim][NTf2], and [C4mim][PF6] ionic liquids has been explored using linear sweep and square wave voltammetry. Cathodic stripping voltammetry at a silver disk electrode is found to be the most sensitive. The methodology is based on first holding the potential of the electrode at +2.0 V (vs Ag wire), to accumulate silver chloride at the electrode. On applying a cathodic scan, a stripping wave is observed corresponding to the reduction of the silver chloride. This stripping protocol was found to detect ppb levels of chloride in [C4mim][BF4], [C4mim][NTf2], and [C4mim][PF6]. Although other methods for chloride have been reported for [BF4](-)- and [PF6](-)-based ionic liquids, no methods have been reported for [NTf2](-) ionic liquids.
first_indexed 2024-03-07T00:13:55Z
format Journal article
id oxford-uuid:7a2e43be-bdfe-4c77-986e-d07be4cbfdb5
institution University of Oxford
language English
last_indexed 2024-03-07T00:13:55Z
publishDate 2004
record_format dspace
spelling oxford-uuid:7a2e43be-bdfe-4c77-986e-d07be4cbfdb52022-03-26T20:42:12ZElectroanalytical determination of trace chloride in room-temperature ionic liquids.Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:7a2e43be-bdfe-4c77-986e-d07be4cbfdb5EnglishSymplectic Elements at Oxford2004Villagrán, CBanks, CHardacre, CCompton, RThe electroanalytical quantification of chloride in [C4mim][BF4], [C4mim][NTf2], and [C4mim][PF6] ionic liquids has been explored using linear sweep and square wave voltammetry. Cathodic stripping voltammetry at a silver disk electrode is found to be the most sensitive. The methodology is based on first holding the potential of the electrode at +2.0 V (vs Ag wire), to accumulate silver chloride at the electrode. On applying a cathodic scan, a stripping wave is observed corresponding to the reduction of the silver chloride. This stripping protocol was found to detect ppb levels of chloride in [C4mim][BF4], [C4mim][NTf2], and [C4mim][PF6]. Although other methods for chloride have been reported for [BF4](-)- and [PF6](-)-based ionic liquids, no methods have been reported for [NTf2](-) ionic liquids.
spellingShingle Villagrán, C
Banks, C
Hardacre, C
Compton, R
Electroanalytical determination of trace chloride in room-temperature ionic liquids.
title Electroanalytical determination of trace chloride in room-temperature ionic liquids.
title_full Electroanalytical determination of trace chloride in room-temperature ionic liquids.
title_fullStr Electroanalytical determination of trace chloride in room-temperature ionic liquids.
title_full_unstemmed Electroanalytical determination of trace chloride in room-temperature ionic liquids.
title_short Electroanalytical determination of trace chloride in room-temperature ionic liquids.
title_sort electroanalytical determination of trace chloride in room temperature ionic liquids
work_keys_str_mv AT villagranc electroanalyticaldeterminationoftracechlorideinroomtemperatureionicliquids
AT banksc electroanalyticaldeterminationoftracechlorideinroomtemperatureionicliquids
AT hardacrec electroanalyticaldeterminationoftracechlorideinroomtemperatureionicliquids
AT comptonr electroanalyticaldeterminationoftracechlorideinroomtemperatureionicliquids