Performance of the CMS cathode strip chambers with cosmic rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was meas...
Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Format: | Journal article |
Published: |
2010
|
_version_ | 1826280794582155264 |
---|---|
author | Chatrchyan, S Khachatryan, V Sirunyan, A Adam, W Arnold, B Bergauer, H Bergauer, T Dragicevic, M Eichberger, M Eroe, J Friedl, M Fruehwirth, R Ghete, V Hammer, J Haensel, S Hoch, M Hoermann, N Hrubec, J Jeitler, M Kasieczka, G Kastner, K Krammer, M Liko, D de Abril, I Mikulec, I |
author_facet | Chatrchyan, S Khachatryan, V Sirunyan, A Adam, W Arnold, B Bergauer, H Bergauer, T Dragicevic, M Eichberger, M Eroe, J Friedl, M Fruehwirth, R Ghete, V Hammer, J Haensel, S Hoch, M Hoermann, N Hrubec, J Jeitler, M Kasieczka, G Kastner, K Krammer, M Liko, D de Abril, I Mikulec, I |
author_sort | Chatrchyan, S |
collection | OXFORD |
description | The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA. |
first_indexed | 2024-03-07T00:19:04Z |
format | Journal article |
id | oxford-uuid:7be2869d-c290-45d1-9467-ff56ad95fd2a |
institution | University of Oxford |
last_indexed | 2024-03-07T00:19:04Z |
publishDate | 2010 |
record_format | dspace |
spelling | oxford-uuid:7be2869d-c290-45d1-9467-ff56ad95fd2a2022-03-26T20:53:34ZPerformance of the CMS cathode strip chambers with cosmic raysJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:7be2869d-c290-45d1-9467-ff56ad95fd2aSymplectic Elements at Oxford2010Chatrchyan, SKhachatryan, VSirunyan, AAdam, WArnold, BBergauer, HBergauer, TDragicevic, MEichberger, MEroe, JFriedl, MFruehwirth, RGhete, VHammer, JHaensel, SHoch, MHoermann, NHrubec, JJeitler, MKasieczka, GKastner, KKrammer, MLiko, Dde Abril, IMikulec, IThe Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA. |
spellingShingle | Chatrchyan, S Khachatryan, V Sirunyan, A Adam, W Arnold, B Bergauer, H Bergauer, T Dragicevic, M Eichberger, M Eroe, J Friedl, M Fruehwirth, R Ghete, V Hammer, J Haensel, S Hoch, M Hoermann, N Hrubec, J Jeitler, M Kasieczka, G Kastner, K Krammer, M Liko, D de Abril, I Mikulec, I Performance of the CMS cathode strip chambers with cosmic rays |
title | Performance of the CMS cathode strip chambers with cosmic rays |
title_full | Performance of the CMS cathode strip chambers with cosmic rays |
title_fullStr | Performance of the CMS cathode strip chambers with cosmic rays |
title_full_unstemmed | Performance of the CMS cathode strip chambers with cosmic rays |
title_short | Performance of the CMS cathode strip chambers with cosmic rays |
title_sort | performance of the cms cathode strip chambers with cosmic rays |
work_keys_str_mv | AT chatrchyans performanceofthecmscathodestripchamberswithcosmicrays AT khachatryanv performanceofthecmscathodestripchamberswithcosmicrays AT sirunyana performanceofthecmscathodestripchamberswithcosmicrays AT adamw performanceofthecmscathodestripchamberswithcosmicrays AT arnoldb performanceofthecmscathodestripchamberswithcosmicrays AT bergauerh performanceofthecmscathodestripchamberswithcosmicrays AT bergauert performanceofthecmscathodestripchamberswithcosmicrays AT dragicevicm performanceofthecmscathodestripchamberswithcosmicrays AT eichbergerm performanceofthecmscathodestripchamberswithcosmicrays AT eroej performanceofthecmscathodestripchamberswithcosmicrays AT friedlm performanceofthecmscathodestripchamberswithcosmicrays AT fruehwirthr performanceofthecmscathodestripchamberswithcosmicrays AT ghetev performanceofthecmscathodestripchamberswithcosmicrays AT hammerj performanceofthecmscathodestripchamberswithcosmicrays AT haensels performanceofthecmscathodestripchamberswithcosmicrays AT hochm performanceofthecmscathodestripchamberswithcosmicrays AT hoermannn performanceofthecmscathodestripchamberswithcosmicrays AT hrubecj performanceofthecmscathodestripchamberswithcosmicrays AT jeitlerm performanceofthecmscathodestripchamberswithcosmicrays AT kasieczkag performanceofthecmscathodestripchamberswithcosmicrays AT kastnerk performanceofthecmscathodestripchamberswithcosmicrays AT krammerm performanceofthecmscathodestripchamberswithcosmicrays AT likod performanceofthecmscathodestripchamberswithcosmicrays AT deabrili performanceofthecmscathodestripchamberswithcosmicrays AT mikuleci performanceofthecmscathodestripchamberswithcosmicrays |