Development and characterization of an automated portable wound irrigation device for diabetic ulcers

Patients with diabetes mellitus may experience peripheral neuropathy and extremity system impairment, which may lead to ulceration if the treatments are delayed. Diabetic ulcers, unfortunately, are chronic, which require proper treatments, including debridement and bacterial removal using an irrigat...

Full description

Bibliographic Details
Main Authors: Nadhif, MH, Assyarify, H, Irsyad, M, Yunir, E, Tarigan, TJE, Sarumpaet, A, Iswati, E
Format: Journal article
Language:English
Published: Institute of Advanced Engineering and Science 2022
_version_ 1797110185668378624
author Nadhif, MH
Assyarify, H
Irsyad, M
Yunir, E
Tarigan, TJE
Sarumpaet, A
Iswati, E
author_facet Nadhif, MH
Assyarify, H
Irsyad, M
Yunir, E
Tarigan, TJE
Sarumpaet, A
Iswati, E
author_sort Nadhif, MH
collection OXFORD
description Patients with diabetes mellitus may experience peripheral neuropathy and extremity system impairment, which may lead to ulceration if the treatments are delayed. Diabetic ulcers, unfortunately, are chronic, which require proper treatments, including debridement and bacterial removal using an irrigation device. To date, commercial irrigation devices included pulsed-lavage, bulb syringe, and gravity bags. Unfortunately, the devices have limitations in terms of portability, measurability, controllability, and disposability. To tackle the limitations, this study aims to design, fabricate, and characterize an automated portable wound irrigation device (Apdice), which is controllable non-disposable, and portable. The device was designed and fabricated using a lightweight construction, a rechargeable battery, and non-disposable materials to support the portability and non-disposable means. Meanwhile, the proportional-derivative-integral controller with its peripheral components were featured to enable controllability. Furthermore, the device was also tested regarding the contamination using a particle counter, and appeared to be contamination free. In short, Apdice showed a robust technological performance. However, it is also worth the try to test the contamination test against biological agents to guarantee the biocompatibility of the device.
first_indexed 2024-03-07T07:51:07Z
format Journal article
id oxford-uuid:7d74d1b7-2d3b-4c88-ab17-dbd9be6ac9fd
institution University of Oxford
language English
last_indexed 2024-03-07T07:51:07Z
publishDate 2022
publisher Institute of Advanced Engineering and Science
record_format dspace
spelling oxford-uuid:7d74d1b7-2d3b-4c88-ab17-dbd9be6ac9fd2023-07-13T15:48:11ZDevelopment and characterization of an automated portable wound irrigation device for diabetic ulcersJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:7d74d1b7-2d3b-4c88-ab17-dbd9be6ac9fdEnglishSymplectic ElementsInstitute of Advanced Engineering and Science2022Nadhif, MHAssyarify, HIrsyad, MYunir, ETarigan, TJESarumpaet, AIswati, EPatients with diabetes mellitus may experience peripheral neuropathy and extremity system impairment, which may lead to ulceration if the treatments are delayed. Diabetic ulcers, unfortunately, are chronic, which require proper treatments, including debridement and bacterial removal using an irrigation device. To date, commercial irrigation devices included pulsed-lavage, bulb syringe, and gravity bags. Unfortunately, the devices have limitations in terms of portability, measurability, controllability, and disposability. To tackle the limitations, this study aims to design, fabricate, and characterize an automated portable wound irrigation device (Apdice), which is controllable non-disposable, and portable. The device was designed and fabricated using a lightweight construction, a rechargeable battery, and non-disposable materials to support the portability and non-disposable means. Meanwhile, the proportional-derivative-integral controller with its peripheral components were featured to enable controllability. Furthermore, the device was also tested regarding the contamination using a particle counter, and appeared to be contamination free. In short, Apdice showed a robust technological performance. However, it is also worth the try to test the contamination test against biological agents to guarantee the biocompatibility of the device.
spellingShingle Nadhif, MH
Assyarify, H
Irsyad, M
Yunir, E
Tarigan, TJE
Sarumpaet, A
Iswati, E
Development and characterization of an automated portable wound irrigation device for diabetic ulcers
title Development and characterization of an automated portable wound irrigation device for diabetic ulcers
title_full Development and characterization of an automated portable wound irrigation device for diabetic ulcers
title_fullStr Development and characterization of an automated portable wound irrigation device for diabetic ulcers
title_full_unstemmed Development and characterization of an automated portable wound irrigation device for diabetic ulcers
title_short Development and characterization of an automated portable wound irrigation device for diabetic ulcers
title_sort development and characterization of an automated portable wound irrigation device for diabetic ulcers
work_keys_str_mv AT nadhifmh developmentandcharacterizationofanautomatedportablewoundirrigationdevicefordiabeticulcers
AT assyarifyh developmentandcharacterizationofanautomatedportablewoundirrigationdevicefordiabeticulcers
AT irsyadm developmentandcharacterizationofanautomatedportablewoundirrigationdevicefordiabeticulcers
AT yunire developmentandcharacterizationofanautomatedportablewoundirrigationdevicefordiabeticulcers
AT tarigantje developmentandcharacterizationofanautomatedportablewoundirrigationdevicefordiabeticulcers
AT sarumpaeta developmentandcharacterizationofanautomatedportablewoundirrigationdevicefordiabeticulcers
AT iswatie developmentandcharacterizationofanautomatedportablewoundirrigationdevicefordiabeticulcers