Application of V-doped TiO2 as a sensor for detection of SO2

Changes in the resistivity of polycrystalline V-doped TiO2 upon exposure to SO2 in air allow application of the material as a sensor for detection of this important pollutant. Optimal sensitivity to SO2 is achieved at low doping levels, where there is also good selectivity relative to CO and CH4. Co...

Full description

Bibliographic Details
Main Authors: Morris, D, Egdell, R
Format: Journal article
Language:English
Published: 2001
_version_ 1797078025684123648
author Morris, D
Egdell, R
author_facet Morris, D
Egdell, R
author_sort Morris, D
collection OXFORD
description Changes in the resistivity of polycrystalline V-doped TiO2 upon exposure to SO2 in air allow application of the material as a sensor for detection of this important pollutant. Optimal sensitivity to SO2 is achieved at low doping levels, where there is also good selectivity relative to CO and CH4. Concentration of SO2 as low as 10 ppm† produce a 10% change in the resistance of 0.5% V-doped TiO2, allowing facile detection of the gas at this level. Analysis of the kinetics of the resistance changes for 1% V-doped TiO2 as a function of temperature shows that the rate of initial response is only weakly activated.
first_indexed 2024-03-07T00:26:32Z
format Journal article
id oxford-uuid:7e52e734-c338-4ac8-b5b3-001451d45cd8
institution University of Oxford
language English
last_indexed 2024-03-07T00:26:32Z
publishDate 2001
record_format dspace
spelling oxford-uuid:7e52e734-c338-4ac8-b5b3-001451d45cd82022-03-26T21:09:26ZApplication of V-doped TiO2 as a sensor for detection of SO2Journal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:7e52e734-c338-4ac8-b5b3-001451d45cd8EnglishSymplectic Elements at Oxford2001Morris, DEgdell, RChanges in the resistivity of polycrystalline V-doped TiO2 upon exposure to SO2 in air allow application of the material as a sensor for detection of this important pollutant. Optimal sensitivity to SO2 is achieved at low doping levels, where there is also good selectivity relative to CO and CH4. Concentration of SO2 as low as 10 ppm† produce a 10% change in the resistance of 0.5% V-doped TiO2, allowing facile detection of the gas at this level. Analysis of the kinetics of the resistance changes for 1% V-doped TiO2 as a function of temperature shows that the rate of initial response is only weakly activated.
spellingShingle Morris, D
Egdell, R
Application of V-doped TiO2 as a sensor for detection of SO2
title Application of V-doped TiO2 as a sensor for detection of SO2
title_full Application of V-doped TiO2 as a sensor for detection of SO2
title_fullStr Application of V-doped TiO2 as a sensor for detection of SO2
title_full_unstemmed Application of V-doped TiO2 as a sensor for detection of SO2
title_short Application of V-doped TiO2 as a sensor for detection of SO2
title_sort application of v doped tio2 as a sensor for detection of so2
work_keys_str_mv AT morrisd applicationofvdopedtio2asasensorfordetectionofso2
AT egdellr applicationofvdopedtio2asasensorfordetectionofso2