Anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in water

We report a sensitive stripping voltammetry method for the detection of total arsenic in aqueous solution using gold macroelectrodes based on the underpotential deposition (UPD) of As ad-atoms. The detection of As(III) or total arsenic can be selectively made by changing deposition potential, with d...

وصف كامل

التفاصيل البيبلوغرافية
المؤلفون الرئيسيون: Zhang, Y, Compton, RG
التنسيق: Journal article
اللغة:English
منشور في: Elsevier 2022
_version_ 1826307956934705152
author Zhang, Y
Compton, RG
author_facet Zhang, Y
Compton, RG
author_sort Zhang, Y
collection OXFORD
description We report a sensitive stripping voltammetry method for the detection of total arsenic in aqueous solution using gold macroelectrodes based on the underpotential deposition (UPD) of As ad-atoms. The detection of As(III) or total arsenic can be selectively made by changing deposition potential, with detection of the total As content by deposition at high potential (- 1.3 V) and of As(III) by deposition at lower potential (- 0.9 V). Linear responses were found for both arsenic species in the range 0.01 μM to 0.1 μM at gold macroelectrodes. The analytical useful signals were recorded at concentrations as low as 0.01 μM (0.8 μg L-1 ) for both arsenic species suggesting that this method can be used to detect total arsenic concentrations in drinking water within the threshold value of the WHO of 0.13 μM (10 μg L-1 ).
first_indexed 2024-03-07T07:10:56Z
format Journal article
id oxford-uuid:7fc9b72d-2efc-4b1b-b58b-7eca17eb6113
institution University of Oxford
language English
last_indexed 2024-03-07T07:10:56Z
publishDate 2022
publisher Elsevier
record_format dspace
spelling oxford-uuid:7fc9b72d-2efc-4b1b-b58b-7eca17eb61132022-06-23T10:35:18ZAnodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in waterJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:7fc9b72d-2efc-4b1b-b58b-7eca17eb6113EnglishSymplectic ElementsElsevier2022Zhang, YCompton, RGWe report a sensitive stripping voltammetry method for the detection of total arsenic in aqueous solution using gold macroelectrodes based on the underpotential deposition (UPD) of As ad-atoms. The detection of As(III) or total arsenic can be selectively made by changing deposition potential, with detection of the total As content by deposition at high potential (- 1.3 V) and of As(III) by deposition at lower potential (- 0.9 V). Linear responses were found for both arsenic species in the range 0.01 μM to 0.1 μM at gold macroelectrodes. The analytical useful signals were recorded at concentrations as low as 0.01 μM (0.8 μg L-1 ) for both arsenic species suggesting that this method can be used to detect total arsenic concentrations in drinking water within the threshold value of the WHO of 0.13 μM (10 μg L-1 ).
spellingShingle Zhang, Y
Compton, RG
Anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in water
title Anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in water
title_full Anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in water
title_fullStr Anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in water
title_full_unstemmed Anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in water
title_short Anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total As and As(III) in water
title_sort anodic stripping voltammetry using underpotential deposition allows sub 10 ppb measurement of total as and as iii in water
work_keys_str_mv AT zhangy anodicstrippingvoltammetryusingunderpotentialdepositionallowssub10ppbmeasurementoftotalasandasiiiinwater
AT comptonrg anodicstrippingvoltammetryusingunderpotentialdepositionallowssub10ppbmeasurementoftotalasandasiiiinwater