Multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes

<p>Background</p> <p>Vascular surgical care has changed dramatically in recent years with little knowledge of the impact of system failures on patient safety. The primary aim of this multicentre observational study was to define the landscape of surgical system failures, errors and...

Full description

Bibliographic Details
Main Authors: Vincent, C, Lear, R, Riga, C, Godfrey, A, Falaschetti, E, Cheshire, N, Van Herzeele, I, Norton, C, Darzi, A, Bicknell, C
Format: Journal article
Published: Wiley 2016
_version_ 1797078721603043328
author Vincent, C
Lear, R
Riga, C
Godfrey, A
Falaschetti, E
Cheshire, N
Van Herzeele, I
Norton, C
Darzi, A
Bicknell, C
author_facet Vincent, C
Lear, R
Riga, C
Godfrey, A
Falaschetti, E
Cheshire, N
Van Herzeele, I
Norton, C
Darzi, A
Bicknell, C
author_sort Vincent, C
collection OXFORD
description <p>Background</p> <p>Vascular surgical care has changed dramatically in recent years with little knowledge of the impact of system failures on patient safety. The primary aim of this multicentre observational study was to define the landscape of surgical system failures, errors and inefficiency (collectively termed failures) in aortic surgery. Secondary aims were to investigate determinants of these failures and their relationship with patient outcomes.</p> <br/> <p>Methods</p> <p>Twenty vascular teams at ten English hospitals trained in structured self‐reporting of intraoperative failures (phase I). Failures occurring in open and endovascular aortic procedures were reported in phase II. Failure details (category, delay, consequence), demographic information (patient, procedure, team experience) and outcomes were reported. <br/> <p>Results</p> <p>There were strong correlations between the trainer and teams for the number and type of failures recorded during 88 procedures in phase I. In 185 aortic procedures, teams reported a median of 3 (i.q.r. 2–6) failures per procedure. Most frequent failures related to equipment (unavailability, failure, configuration, desterilization). Most major failures related to communication. Fourteen failures directly harmed 12 patients. Significant predictors of an increased failure rate were: endovascular compared with open repair (incidence rate ratio (IRR) for open repair 0·71, 95 per cent c.i. 0·57 to 0·88; P = 0·002), thoracic aneurysms compared with other aortic pathologies (IRR 2·07, 1·39 to 3·08; P ≺ 0·001) and unfamiliarity with equipment (IRR 1·52, 1·20 to 1·91; P ≺ 0·001). The major failure total was associated with reoperation (P = 0·011), major complications (P = 0·029) and death (P = 0·027).</p> <br/> <p>Conclusion</p> <p>Failure in aortic procedures is frequently caused by issues with team‐working and equipment, and is associated with patient harm. Multidisciplinary team training, effective use of technology and new‐device accreditation may improve patient outcomes.</p></p>
first_indexed 2024-03-07T00:35:47Z
format Journal article
id oxford-uuid:8158dc08-d489-4e19-b03d-5ded3b3350be
institution University of Oxford
last_indexed 2024-03-07T00:35:47Z
publishDate 2016
publisher Wiley
record_format dspace
spelling oxford-uuid:8158dc08-d489-4e19-b03d-5ded3b3350be2022-03-26T21:29:46ZMulticentre observational study of surgical system failures in aortic procedures and their effect on patient outcomesJournal articlehttp://purl.org/coar/resource_type/c_dcae04bcuuid:8158dc08-d489-4e19-b03d-5ded3b3350beSymplectic Elements at OxfordWiley2016Vincent, CLear, RRiga, CGodfrey, AFalaschetti, ECheshire, NVan Herzeele, INorton, CDarzi, ABicknell, C<p>Background</p> <p>Vascular surgical care has changed dramatically in recent years with little knowledge of the impact of system failures on patient safety. The primary aim of this multicentre observational study was to define the landscape of surgical system failures, errors and inefficiency (collectively termed failures) in aortic surgery. Secondary aims were to investigate determinants of these failures and their relationship with patient outcomes.</p> <br/> <p>Methods</p> <p>Twenty vascular teams at ten English hospitals trained in structured self‐reporting of intraoperative failures (phase I). Failures occurring in open and endovascular aortic procedures were reported in phase II. Failure details (category, delay, consequence), demographic information (patient, procedure, team experience) and outcomes were reported. <br/> <p>Results</p> <p>There were strong correlations between the trainer and teams for the number and type of failures recorded during 88 procedures in phase I. In 185 aortic procedures, teams reported a median of 3 (i.q.r. 2–6) failures per procedure. Most frequent failures related to equipment (unavailability, failure, configuration, desterilization). Most major failures related to communication. Fourteen failures directly harmed 12 patients. Significant predictors of an increased failure rate were: endovascular compared with open repair (incidence rate ratio (IRR) for open repair 0·71, 95 per cent c.i. 0·57 to 0·88; P = 0·002), thoracic aneurysms compared with other aortic pathologies (IRR 2·07, 1·39 to 3·08; P ≺ 0·001) and unfamiliarity with equipment (IRR 1·52, 1·20 to 1·91; P ≺ 0·001). The major failure total was associated with reoperation (P = 0·011), major complications (P = 0·029) and death (P = 0·027).</p> <br/> <p>Conclusion</p> <p>Failure in aortic procedures is frequently caused by issues with team‐working and equipment, and is associated with patient harm. Multidisciplinary team training, effective use of technology and new‐device accreditation may improve patient outcomes.</p></p>
spellingShingle Vincent, C
Lear, R
Riga, C
Godfrey, A
Falaschetti, E
Cheshire, N
Van Herzeele, I
Norton, C
Darzi, A
Bicknell, C
Multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes
title Multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes
title_full Multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes
title_fullStr Multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes
title_full_unstemmed Multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes
title_short Multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes
title_sort multicentre observational study of surgical system failures in aortic procedures and their effect on patient outcomes
work_keys_str_mv AT vincentc multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT learr multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT rigac multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT godfreya multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT falaschettie multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT cheshiren multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT vanherzeelei multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT nortonc multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT darzia multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes
AT bicknellc multicentreobservationalstudyofsurgicalsystemfailuresinaorticproceduresandtheireffectonpatientoutcomes